• Title/Summary/Keyword: Dipole-dipole Array

Search Result 163, Processing Time 0.029 seconds

Application of Mutiple Geophysical Methods in Investigating the Lava Tunnel of Manjanggul in Cheju Island (제주도 만장굴에 대한 복합 지구물리탐사 기법의 적용)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Oh, Seok-Hoon;Lee, Chun-Ki
    • Economic and Environmental Geology
    • /
    • v.31 no.6
    • /
    • pp.535-545
    • /
    • 1998
  • Various geophysical methods have been applied to the survey of the lava tunnel of Manjanggul in Cheju Island to study the effectiveness of each method in investigating underground tunnels. The surveys employing gravity, magnetic, electrical, AMT and VLF methods were carried out along seven profiles across the Manjanggul; especially, all the five methods were used on one representative profile. Several aspects of different methods pertinent to their use in investigation of underground tunnels have been noted. The electrical method employing the dipole-dipole array appeared to be the most effective one among five methods. Therefore, we have tested the electrical method more carefully by using various electrode spacings, and obtained successful resistivity sections showing the existence of lava tunnels. The gravity method provided relatively successful responses associated with the tunnel although the gravity readings were contaminated by wind blowing during the survey. The gravity data were also useful for the quantitative modeling study. The magnetic data were also successful in delineating the tunnel qualitatively. The AMT data were not successful because the used frequency band was not appropriate in detecting very shallow target. The VLF data were severely influenced by the neighboring noise sources such as power lines and were not successful in detecting the tunnel responses. The comprehensive result of electrical, gravity and magnetic surveys suggests that undiscovered lava tunnels may exist adjacent to the Manjanggul.

  • PDF

Case Studies of Electrical Resistivity Imaging Technique in Civil & Environmental Engineering Areas (전기비저항 영상화 기법의 토목 및 환경분야 적용사례연구)

  • 정연문;김정호
    • Geotechnical Engineering
    • /
    • v.14 no.4
    • /
    • pp.91-102
    • /
    • 1998
  • Electrical resistivity method, one of the most widely used geophysical prospecting methods. has been usually applied to explorations for groundwater and underground resources. However, it has been extending its scope to civil & environmental engineering areas since it twas been developed so as to image underground structures effectively. A FEM algorithm for the dipole-dipole array was developed to correct topographic effects which have a serious influence on electrical methods. Applicability of the electrical resistivity imaging technique to civil & environmental engineering areas was verified through three case histories in this study First, thickness of soil layers was profiled to judge the possibility of developing borrow-pits tn an industrial complect site. Second, weak zones such as fractures and coal seams were detected to provide geological information for design and construction in a high mountain tunnel site. Third, horizontal/vertical distribution of the contaminated zone and depth of waste disposal were delineated in a completed industrial waste disposal site.

  • PDF

Application of Geophysical Survey for Detecting the Skarn Ore Deposit (스카른광체를 탐지하기 위한 물리탐사 적용)

  • Park, Chung-Hwa;Jung, Yeon-Ho;Lee, Yong-Dong;Park, Jong-Oh
    • The Journal of Engineering Geology
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 2010
  • The Gagok mine is a contact metasomatic deposit, located at Gagok-myeon, Samcheok city and Cheoram-dong, Taebaek city, Gangwon province. The deposit lies within the limestone of Myobong and Pungchon formations, and exists the contact of intrusive granite porphyry. In order to determine the direction and extension of mineralization in the gallery and around the entrance of the ore deposit, we used the ground magnetic survey, the direct current (dc) resistivity survey using dipole-dipole array, and resistivity tomography survey. The ground magnetic survey did not detect the anomalous zone due to ore deposit, while the dc resistivity survey and resistivity tomography survey were successful in delineating the anomalous zone related to the extension of fault toward $N50^{\circ}W$.

Case Study of Assessment of Slope Stability and Geophysical Survey in Weathered Gneiss (편마암 풍화사면에서의 지구물리탐사 및 안정성 해석 사례연구)

  • Kim, Man-Il;Kim, Jong-Tae;Kim, Jae-Hong;Ro, Byung-Don;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.18 no.3
    • /
    • pp.287-295
    • /
    • 2008
  • Rock slope has a variety of irregular discontinuities and represents a discontinuous mass. Rock joint plays an important role of control hydraulic and mechanic movements in the rock mass. These characteristics between hydraulic and mechanic movements at the rock joints could be represent difference. Therefore they are quiet important factor for slope design. In this study the weathered rock slopes were carried out to analysis of slope stability and geophysical survey. The electrical resistivity survey with dipole-dipole array conducted five profiling sites, and SWEDGE and SLIDE for slope stability analysis were applied on 20 rock slopes far assessment of slope stability and understand to geological situations due to the weathering.

Geophysical Survey in the Taran Area on the Central Kalimantan, Indonesia (인도네시아 중부 칼리만탄 타란지역에서의 물리탐사)

  • 조진동;김인준;박인화
    • Economic and Environmental Geology
    • /
    • v.35 no.2
    • /
    • pp.155-162
    • /
    • 2002
  • There are many typical epithermal deposits scattering in the Taran of central Kalimantan. Indonesia. To get the shallow geological information, we carried out the geophysical exploration: spontaneous potential survey, in-suite magnetic susceptibility measurement and relistivity survey method in this area for a few weeks from September 30th to October 27th in 1997. SP survey (Fluke 27 multimeter)/magnetic susceptibility (EK -7 meter) measurement was carried out with a 250m$\times$10m lattice net in N45$^{\circ}$W direction. The dipole-dipole array resistivity survey was conducted with an electrode spacing of ${\alpha}$=30 m and electrode separation index n=7 at the line 5. The result shows that was the gold bearing quartz vein area can be divided into two type lone: low sulfidation type and high sulfidation type zone. The low resistivity value in the survey line 5 indicated a fracture Bone associated with the high sulfidation zone.

Effectiveness of the Electrode Arrays for Delineating 2-D Subsurface Structure (2차원 지하구조 규명을 위한 전극배열의 효율성)

  • Yoon, Jong-Ryeol;Lee, Kiehwa
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.345-355
    • /
    • 1996
  • The effectiveness of various electrode configurations in horizontal mappings and 1-D inversions of vertical sounding data for delineating 2-D structures was studied. Apparent resistivity values of three point, dipole-dipole, Wenner, and Schlumberger mappings were simulated for such structures as vertical dyke, tabular prism, buried vertical fault, ramp and complex structure by finite difference method (FDM) and they were compared with each other. Also 2-D cross sections for three structures obtained by interpolation of 1-D inverted sounding data in terms of three layers were compared for Schlumberger and Wenner arrays. On these cross sections, horizontal and vertical resistivity interfaces of the 2-D structures are revealed relatively clearly. Apparent resistivity curves of Schlumberger mapping show vertical resistivity discontinuities very well. On the whole, Schlumberger array is superior to the other arrays in electric sounding as well as mapping. This study clearly indicates that interpretations of 2-D structures based on 1-D inversion are possible.

  • PDF

Application of hydrogeological and geophysical methods to delineate leakage pathways in an earth fill dam (사력댐 누수경로 파악을 위한 수리지질과 지구물리 방법의 적용)

  • Song Sung-Ho;Song Yoonho;Kwon Byung-Doo
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.92-96
    • /
    • 2005
  • Comprehensive field surveys, including various hydrogeological and geophysical methods, were carried out to appraise the applicability of those methods to a leakage problem at the Sandong earth fill dam in southwestern Korea. The methods applied in the fold site were tracer tests, monitoring of drawdown and leakage with discharge of reservoir water, electrical resistivity surveys using the dipole-dipole array, self-potential (SP), and temperature logging methods. The leakage pattern in the reservoir wall was demonstrated by hydrogeological methods and was further clarified by the geophysical surveys. Leakage turned out to be through the right abutment of the reservoir wall. In this study, we conformed that the electrical resistivity method is effective in detecting the zones favorable to leakage, and SP methods are useful for delineating the leakage pathways themselves, because leaks generate strong streaming-potential anomalies.

A Study on the Applicaton of Electrical Resistivity Survey in the Contaminated Soil and Groundwater Site (토양 및 지하수 오염지역에 대한 전기비저항탐사의 적용성 연구)

  • Chae, Seungheon;Lee, Sangeun;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.525-539
    • /
    • 2020
  • A site containing buried solid waste and treated water and oil storage containers from a leather manufacturing plant was studied through soil and groundwater pollution and electrical resistivity surveys with the aim of identifying areas polluted by leachate generated by landfilling with leather waste and leakage wastewater. It was found that TPH and Zn exceeded environmental standards for soil pollution and, for leachate and groundwater, Cr(VI) concentrations exceeded standard levels for groundwater quality. An electrical resistivity survey was used to elucidate soil and groundwater pollution characteristics and diffusion pathways. Ten survey lines were set up with an electrode spacing of 5 m in a dipole-dipole array. The hydraulic characteristics of soil determined by groundwater contamination surveys matched well the low-resistivity-anomaly zones. Electrical resistivity surveys of areas containing contaminated soil and groundwater that have irregular strata due to waste reclamation are thus useful in highlighting vertical and horizontal pollutant diffusion pathways and in monitoring contaminated and potentially contaminated areas.

Nonlinear Inversion of Time-domain Induced Polarization Data with Negative Apparent Chargeability Data (음의 겉보기 충전성 자료를 포함한 시간영역 유도분극 자료의 비선형 역산)

  • Cho, In-Ky;Kim, Yeon-Jung
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.4
    • /
    • pp.139-148
    • /
    • 2021
  • Negative apparent chargeability data in time-domain induced polarization (IP) survey are very often considered as noise and rejected before the inversion stage. Negative IP data can, however, occur naturally as a consequence of the distribution of chargeable zones in the ground. In some cases, the negative apparent chargeability values may account for most of the data measured. Negative IP data are caused by the geometry of chargeable zones and electrode positions. Negative apparent chargeability data appear most frequently when a dipole-dipole array is used. In this study, the effect of negative apparent chargeability data on inversion results is analyzed through the numerical 2D time-domain IP modeling and nonlinear inversion. The results demonstrate clearly that negative apparent chargeability data have to be included in the inversion as they contain important information on the distribution of subsurface chargeability.

Electrical and Hydraulic Characteristics of An Alluvial Bed under the Influence of Pumping and Rainfall

  • Woo-Ri Lim;Nam-Hoon Kim;Samgyu Park;Jae-Yeol Cheong;Se-Yeong Hamm
    • Journal of the Korean earth science society
    • /
    • v.45 no.4
    • /
    • pp.363-376
    • /
    • 2024
  • Alluvial beds are intimately associated with electrical properties related to soil types, including clay mineral content, porosity, and water content. The hydraulic property governs water movement and storage in alluvial beds. This study revealed electrical resistivity and hydraulic properties in space and time in relation to the hydrogeological data, groundwater pumping, and rainfall infiltration into the alluvial bed located in Daesan-myeon, Changwon City. An electrical resistivity survey with electrode spacings of 2 and 4m using a dipole-dipole array indicates that electrical resistivity changes in the alluvial bed depend on groundwater pumping and rainfall events. Additionally, rainfall infiltration varies with hydraulic conductivity in the shallow zone of the alluvial bed. The 2 m electrode spacing survey confirms that electrical resistivity values decrease at shallow depths, corresponding with rainfall and increased water content in the soil, indicating rainfall infiltration approximately 1-2 m below the land surface. The 4m electrode spacing survey reveals that hydraulic conductivity (K) values and electrical resistivity (ρ) values display an inverse relationship from the surface to the water table (approximately 9 m) and at deeper levels than the water table. Notably, ρ values are impacted by pumping around the depth of the water table at 9 m. This study suggests that time-lapsed electrical resistivity surveys in space and time could be effective tools for detecting the impact of rainfall and pumping, as well as hydraulic conductivity in shallow alluvial beds.