• 제목/요약/키워드: Dip Measurement

검색결과 66건 처리시간 0.019초

천연해수 용액에서 STS 304와 용융 알루미늄 도금된 STS 304의 캐비테이션-침식 환경 하에서의 전기화학적 특성 (Electrochemical Characteristics under Cavitation-Erosion Environment of STS 304 and Hot-Dip Aluminized STS 304 in Sea Water Solution)

  • 정상옥;김성종
    • 한국표면공학회지
    • /
    • 제49권1호
    • /
    • pp.26-31
    • /
    • 2016
  • In this paper, the characteristics of a cavitation-erosion damage behavior on the STS 304 and hot-dip aluminized STS 304 under cavitation environment in sea water solution was investigated. The electrochemical experiments were carried out by potential measurement, anodic/cathodic polarization test, Tafel analysis, and also galvanostatic experiment in current density variables for the samples. The apparatus of cavitation-electrochemical experiment was manufactured in compliance with modified ASTM G-32 standard, with the conditions of sea water temperature of $25^{\circ}C$ and the measurement, amplitude of $30{\mu}m$. The damage behavior was analyzed by an observation of surface mophologies and a measurement of damage depth by a scanning electron microscope(SEM) and a 3D microscope, respectively, after electrochemical test. After polarization experiment under cavitation environment, much higher damage depths for the hot-dip aluminized STS 304 were observed comparing to the untreated STS 304. In addition, higher corrosion current density in hot-dip aluminized STS 304 presented than that of untreated STS 304 as a result of Tafel analysis.

불연속면 방향의 효율적인 측정 방안 (Effective Measuring Method of Discontinuity Orientation)

  • 김해경;고영구
    • 지질공학
    • /
    • 제13권3호
    • /
    • pp.321-334
    • /
    • 2003
  • 본 연구는 암반에서 불연속면 방향의 효율적인 측정 방안에 관한 것이다. 불연속면의 방향성은 주향/경사, 경사방향/경사(세 자리 숫자/두 자리 숫자) 그리고 경사방향을 우측에 두고 바라보는 방향을 주향방향으로 결정하는 방법의 세 가지 방법으로 표현한다. 일반적으로 불연속면의 주향/경사는 클리노미터에 의해 측정이 되며, 경사방향』경사는 실바콤파스(type15)에 의해 측정된다. 주향/경사는 지질조사시에 측정이 되는데, 경사방향/경사는 공학적 목적으로 측정이 되며, 통계처리에 유용하다 클리노미터에 의해 불연속면의 경사방향 측정과 주향/경사를 경사방향/경사로의 전환 시, 측정자에 따라 오류를 유발할 가능성이 있다. 본 연구에서는 불연속면 방향성을 두 가지 방법 (주향/경사. 경사방향/경사)으로 효과적으로 측정하기 위하여 클리노미터에 회전방위판과 주향 및 경사방향 표시 화살표를 부착하여 측정하는 방법을 고안하였다. 이 새로운 측정법은 주향뿐만 아니라 경사방향을 정확하게 측정할 수 있는 효과적인 측정법이다. 또한 이 측정법은 주향/경사 및 경사방향/경사의 동시 측정이 가능하다. 암반사면에서 불연속면의 방향 측정 시, 현행 측정법과 새로운 측정법을 비교한 결과. 새로운 측정법이 오류를 분명히 감소시킴을 알 수 있었다 따라서 새로운 측정법은 도로 설계 시 광역적인 지표지질조사에서 많은 불연속면의 방향성을 측정할 경우와 측정 경험이 부족한 조사자에게 유용한 방법이라고 생각된다.

Tunnel Mapper를 이용한 Tunnel 막장면 조사에 관한 연구 (Study of Tunnel Face Mapping Using Tunnel Mapper)

  • 곽노경;조성진;이송
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 2차
    • /
    • pp.200-211
    • /
    • 2010
  • Tunnel Mapper, which is tunnel face survey system was used to conduct Face Mapping on the face of the tunnel that is under construction. Then, accuracy and utility value on the forecast of discontinuity were verified to verify the field application in order to present the measures for the use of the system for conducting research on the discontinuity. As result of the directivity verification following discontinuity‘s project, forecasted measurement and actually researched measurement error for the Dip direction and Dip angle was less than ${\pm}10$. Accuracy was 82.6% for Dip direction and 90.7% for Dip angle, which are high. Accordingly, face research discontinuity forecasting system's reliability level towards directivity is high. Tunnel Mapper, a tunnel face survey system can be leveraged to replace face's visual survey and to obtain objective information, enabling execution of the survey system that can automate face survey going beyond time and space related limitations.

  • PDF

후두 내시경 영상에서의 성문 분할 및 성대 점막 형태의 정량적 평가 (Segmentation of the Glottis and Quantitative Measurement of the Vocal Cord Mucosal Morphology in the Laryngoscopic Image)

  • 이선민;오석;김영재;우주현;김광기
    • 한국멀티미디어학회논문지
    • /
    • 제25권5호
    • /
    • pp.661-669
    • /
    • 2022
  • The purpose of this study is to compare and analyze Deep Learning (DL) and Digital Image Processing (DIP) techniques using the results of the glottis segmentation of the two methods followed by the quantification of the asymmetric degree of the vocal cord mucosa. The data consists of 40 normal and abnormal images. The DL model is based on Deeplab V3 architecture, and the Canny edge detector algorithm and morphological operations are used for the DIP technique. According to the segmentation results, the average accuracy of the DL model and the DIP was 97.5% and 94.7% respectively. The quantification results showed high correlation coefficients for both the DL experiment (r=0.8512, p<0.0001) and the DIP experiment (r=0.7784, p<0.0001). In the conclusion, the DL model showed relatively higher segmentation accuracy than the DIP. In this paper, we propose the clinical applicability of this technique applying the segmentation and asymmetric quantification algorithm to the glottal area in the laryngoscopic images.

메탄/공기 예혼합화염에서 CARS를 이용한 CO 농도 및 온도측정과 수치해석 결과의 비교 (Comparison of CARS CO and Temperature Measurements with Numerical Calculation for Methane/Air Premixed Flames)

  • 강경태;정석호;박승남
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1333-1339
    • /
    • 1995
  • Recently developed technique of measuring minor species concentration by using the modulation dip in broadband CARS has been applied to the flame structure study of methane/air premixed flames in a counterflow. This method used the modulation dip from the cold band CO Q-branch resonant signal superimposed on the nonresonant background. The measured CO concentration profile in a symmetric and unsymmetric methane/air premixed flames together with the velocity and temperature by using LDV and CARS have been compared with the numerical results adopting detailed chemistry modeling. The results show that there is a satisfactory agreement between the experimental data and numerical results for velocities, temperatures and CO concentrations. And the modulation dip technique of measuring minor species, such as CO is a viable tool for a quantitative measurement in a flame.

알루미늄 용융 도금된 304 스테인리스강의 해수 내 전기화학적 부식 특성 평가 (Evaluation of Electrochemical Corrosion Characteristics for Hot-Dip Aluminized 304 Stainless Steel in Seawater)

  • 정상옥;박일초;한민수;김성종
    • 한국표면공학회지
    • /
    • 제48권6호
    • /
    • pp.354-359
    • /
    • 2015
  • Stainless steel has poor corrosion resistance in marine environment due to the breakdown of a passive film caused by chloride. It suffers electrochemical corrosion like pitting corrosion, crevice corrosion, and stress corrosion crack (SCC) in marine environment. In general, it indicates that the passive film of $Al_2O_3$ has better corrosion resistance than that of $Cr_2O_3$ in seawater. This paper investigated the damage behavior 304 stainless steel and hot-dip aluminized 304 stainless steel in seawater solution. Various electrochemical experiments were carried out including potential measurement, potentiodynaimic experiment, Tafel analysis and galvanostatic experiment. As a result of anodic polarization experiment, higher pitting damage depth was indicated at 304 stainless steel than hot-dip aluminized 304 stainless steel. In addition, relatively higher corrosion current density was shown at hot-dip aluminized stainless steel as a result of Tafel analysis.

Ammonia and Hydrogen Sulfide Removal from Swine House Exhaust Air Using a Dip Injection Wet Scrubber

  • Shin, Myeongcheol;Lee, Seunghun;Wi, Jisoo;Ahn, Heekwon
    • 한국토양비료학회지
    • /
    • 제50권6호
    • /
    • pp.615-622
    • /
    • 2017
  • This study was conducted to evaluate the odor reduction efficacy of the dip injection wet scrubber (DIWS) using tap water as washing fluid. The $NH_3$ and $H_2S$ removal efficiency of 7 day batch operated DIWS was evaluated twice over a total of 14 days of experiment. The $NH_3$ removal efficiency ranged from 26 to 37%. The $H_2S$ removal efficiency was between 22 and 30%. The pH of the washing fluid maintained below 8 and the $NH_4{^+}$ concentration tended to keep constant around 350 ppm after 5 days of washing-fluid replacement. Therefore, the 5-day washing fluid replacement interval is more preferable than the 7-day interval. The $NH_4{^+}$ concentration and the electrical conductivity (EC) showed a high correlation. The EC measurement can be used as an alternative to conventional $NH_4{^+}$ concentration measurement method for real time monitoring of washing fluid condition.

배전선로의 이도설계 및 시공에 대한 실증연구 (Empirical Study on the Dip Design and Installation of Distribution Line Conductors)

  • 안인석
    • 한국산업융합학회 논문집
    • /
    • 제24권3호
    • /
    • pp.307-313
    • /
    • 2021
  • In this study, the comparative analysis, among the design standard value of distribution power, the calculated value from the measurement data of strand and the empirical data of the distribution line itself, have been performed for the elastic coefficients and linear expansion coefficients of distribution line conductors. The empirical values of elastic coefficients were lower about 10.6%(892kgf/mm2) than those of the design standard value of the distribution power and there were a little difference between the empirical values of linear expansion coefficients and the design standard value of the distribution power. From the above results, it could be concluded that the empirical values of conductor characteristics should be used in the dip design and installation of distribution line.

Rotating Wheel Dip Test에 의한 에폭시 절연재료의 내트래킹성과 열화 특성 (Tracking Resistance and Aging Characteristics of Epoxy Insulating Materials by the Rotating Wheel Dip Test)

  • 조한구
    • 한국전기전자재료학회논문지
    • /
    • 제21권6호
    • /
    • pp.530-537
    • /
    • 2008
  • This paper describes the results of a study on the tracking performance of outdoor insulating materials based on the rotating wheel dip test(RWDT). And, the influence of surface degradation was evaluated through such as measurement of the flashover voltage after and before tracking test, also aspects of surface degradation using scanning electron microscopy. The time to tracking breakdown of treated filled specimen is longer than untreated filled specimen. And, after the RWDT, the surface of specimen by adding untreated filler appeared heavy erosion. It was found that the addition to surface treated filler, the better tracking resistance. In the RWDT, the breakdown specimen is not affected by the dry flashover voltage, despite the fact that the surface degradation of tracking test has different state on each specimen. This suggests that wet flashover voltage play an important role in evaluating of tracking and erosion on the surface degradation in tracking test. And, the flashover voltage of specimen under wet conditions are greatly affected by the salt concentration and degree of degradation by the RWDT Because of hydrophobicity and degree of degradation by the RWDT, the flashover voltage of treated filled specimen is higher than that of untreated filled specimen. Different types of specimen may have different hydrophobicity and their surface state under contaminated conditions may not be the same.

용융알루미늄 도금 강판 상에 스퍼터링법으로 형성된 마그네슘 코팅막에 의한 내식성 향상 (Improvement of Corrosion Resistance by Mg Films Deposited on Hot Dip Aluminized Steel using a Sputtering Method)

  • 박재혁;김순호;정재인;양지훈;이경황;이명훈
    • 한국표면공학회지
    • /
    • 제51권4호
    • /
    • pp.224-230
    • /
    • 2018
  • In this study, Mg films were prepared on hot dip aluminized steel (HDA) by using a sputtering method as a high corrosion resistance coating. The corrosion resistance of the Mg films was improved by controlling the morphology and the crystal structure of films by adjusting the Ar gas pressure during the coating process. Anodic polarization measurement results confirm that the corrosion resistance of the Mg films was affected by surface morphology and crystal structure. The corrosion resistance of the Mg coated HDA specimen increased with decreasing crystal size of the Mg coating and it was also improved by forming a film with denser morphology. The crystal structure oriented at Mg(101) plane showed the best corrosion resistance among crystal planes of the Mg metals, which is attributed to its relatively low surface energy. Neutral salt spray test confirmed that corrosion resistance of HDA can be greatly improved by Mg coating, which is superior to that of HDG (hot dip galvanized steel). The reason for the improvement of the corrosion resistance of Mg films on hot dip aluminized steel was due to the barrier effect by the Mg corrosion products formed by the corrosion of the Mg coating layer.