• Title/Summary/Keyword: Dip

Search Result 1,381, Processing Time 0.031 seconds

A Numerical Analysis on the Coating Thickness in Continuous Hot-Dip Galvanizing (연속 아연 도금 코-팅 두께에 관한 수치 해석적 연구)

  • Lee, Dong-Won;Shin, Seung-Young;Kim, Byung-Ji;Kwon, Young-Doo;Kwon, Soon-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2955-2960
    • /
    • 2007
  • To control the coating thickness of zinc in the process of continuous hot-dip galvanizing, it is known from early day that the gas wiping through an air knife system is the most effective because of the obtainable of uniformity of coating thickness, possibility of thin coating, working ability in high speed and simplicity of control. But, the gas wiping using in the galvanizing process brings about a problem of splashing from the strip edge for a certain high speed of coating. And, it is known that the problem of splashing is caused mainly by the existence of separation bubble at the neighbor of the strip surface. In theses connections, in the present study, we proposed two kinds of air knife systems having the same expansion rate of nozzle, and the jet structures and coating thicknesses from a conventional and new proposed nozzles are compared. In numerical analysis, the governing equations consisted of two-dimensional time dependent Navier-Stokes equations, standard ${\kappa}-{\varepsilon}$ turbulence model to solve turbulence stress and so on are employed. As a result, it is found that it had better to use the constant rate nozzle from the point view of the energy saving to obtain the same coating thickness. Also, to reduce the size of separation bubble and to enhance the cutting ability at the strip, it is recommendable to use an air knife having the constant expansion rate nozzle.

  • PDF

A Downwardly Deflected Symmetric Jet to prevent Edge Overcoating in Continuous Hot-Dip Galvanizing (연속식 용융아연도금 공정에서 단부 과도금 현상을 방지하기 위한 하향 대칭 분류유동 연구)

  • Ahn, Gi-Jang;Chung, Myung-Kyoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.10 s.241
    • /
    • pp.1156-1162
    • /
    • 2005
  • In this study, a noble method is proposed to prevent the edge overcoating (EOC) that may develop near the edge of the steel strip in the gas wiping process of continuous hot-dip galvanizing. In our past study (Trans. of the KSME (B), Vol. 27, No. 8, pp. $1105\~1113$), it was found that EOC is caused by the alternating vortices which are generated by the collision of two opposed jets in the region outside the steel strip. When the two opposed jets collide at an angle much less than $180^{o}$, non-alternating stable vortices are established symmetrically outside the steel strip, which lead to nearly uniform pressure on the strip surface. In order to deflect both jets downward by a certain angle, a cylinder with small diameter is installed tangentially to the exit of the lower lip of the two-dimensional jet. In order to find an optimum cylinder diameter, the three dimensional flow field is analysed numerically by using the commercial code, STAR-CD. And the coating thickness is calculated by using an integral analysis method to solve the boundary layer momentum equation. In order to compare the present noble method with the conventional baffle plate method to prevent the EOC, the flow field with a baffle plate is also calculated. The calculation results show that the tangentially installed cylinder at the bottom lip of the jet exit is more effective than the baffle plate to prevent EOC.

Electric Power Line Dips Measurement Using Drone-based Photogrammetric Techniques (드론 기반 사진측량기법을 활용한 고압 송전선의 처짐량 측정)

  • Kim, Yu Jong;Oh, Jae Hong;Lee, Chang No
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2017
  • High voltage power transmission lines have been to keep the proper dip for maintenance. Powerline dips at a random point are conventionally measured by the direct or indirect observation but it is not only unsafe but labor-intensive. Therefore in this study we applied the photogrammetric technique to remotely measure the powerline dips. Since it is not easy to extract conjugate points from linear powerlines, we exploited the epipolar lines acrossing the powerlines for 3D mapping of the powerlines and dip measurements. The vertical mapping accuracy estimated at two field-surveyed power line points was 15~16cm that are within 5% of deflection at the points and less than 3% of the powerline dip.

A Study on the Status of Marine Environment Management of Sea Port Cities - Focused on Busan Metropolitan City and Incheon metropolitan city - (해항도시의 해양환경 관리실태 분석 - 부산광역시와 인천광역시를 중심으로 -)

  • Kim, Sang-Goo
    • Journal of Navigation and Port Research
    • /
    • v.35 no.3
    • /
    • pp.259-263
    • /
    • 2011
  • This study explores ways to improve the actual conditions of ocean environment by conducting a comparative study on the current sea-water quality of Busan Metropolitan City and Incheon Metropolitan City that are representative sea port cities in Korea. The indices used to evaluate the sea-water quality include water temperature, salt content, PH, DO, COD, DIN, T-N, DIP, T-P, Sio2-Si, floating materials, and Chi-a. The findings of the analysis can be summarized as follows: First, ocean environmental states of Busan Metropolitan City and Incheon Metropolitan City are getting increasingly worse between the year of 2000 and 2003. Second, T-N, DIP and T-P have been main contributors in worsening ocean environmental states of Busan Metropolitan City and Incheon Metropolitan City.

Spatial and Temporal Variability of Phytoplankton in Relation to Environmental Factors in Youngil Bay (영일만 수질환경과 식물플랑크톤의 시·공간적 분포)

  • Shim, Jeong-Min;Kwon, Ki-Young;Jeong, Hee-Dong;Choi, Yong-Kyu;Kim, Sang-Woo
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1683-1690
    • /
    • 2013
  • We investigated the spatial and temporal variations of phytoplankton in Youngil Bay as well as the effect of water physico-chemical parameters. Water samples at three stations were collected and measured monthly from May to November in 2010. The taxa of phytoplankton observed in this study were classified as 33 Bacillariophyceae, 23 Dinophyceae, 1 Euglenophyceae, 2 Crysophyceae and 1 Cryptophyceae. The highest biomass of phytoplankton was observed at inner station in September, which was characterized high concentration of dissolved inorganic phosphate(DIP) in surface water after rainfall. Nutrient concentrations, chlorophyll-a and phytoplankton biomass values showed the marked trend to decrease from the inner bay to the outer bay. Pearson's correlation co-efficient between salinity and other water parameters including chlorophyll-a, pH and DIP showed the strong negative relationship r=-0.82, r=-0.78 and r=-0.75 (p<0.01), respectively. These results indicate that the water quality of Youngil Bay could be stimulated by nutrient enriched input from Hyeogsan River discharge, and the spatial and temporal distribution of phytoplankton biomass principally limited to DIP concentration from Hyeogsan river.

A Refurbishment life Diagnosis for Overhead Transmission Conductors using Dip Measurement (이도 측정에 의한 가공송전선 도체의 교체수명 진단)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.139-146
    • /
    • 2008
  • Conductors in overhead transmission lines are exposed under various environmental conditions for a long period of time, so that they may be slowly degraded due to air pollutant or thermal history. Aged conductors may reduce power system reliability and public safety. Therefore, diagnosis of aged conductors in service becomes more important concerns with respect to keeping power delivery stable with a proper capability, replacing aged conductors, or constructing a new line. In this paper, we posed a new method to diagnose the refurbishment life and estimate the remaining life of aged conductors by measuring dips. As analyzing some relations of conductor temperature, conductor current, and tension load, it could be verified that dip exactly shows mechanical tension loss for aged conductor. Based on several simulation results, it was shown that the proposed method may be effectively used to diagnose the refurbishment life or remaining one of overhead conductors.

Gradation Curve of Aggregate using Digital Image Process (디지털 이미지 처리 기법을 이용한 골재의 입도분포곡선)

  • Hwang, Tak-Jin;Cho, Jae-Yoon;Lee, Kwan-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.31-37
    • /
    • 2010
  • Shape conversion coefficient and equivalent diameter for changing 2D image to 3D image by the Digital Image Process(DIP) have been suggested and modified particle size distribution curve has been showed. Couple of aggregates, like two different marine aggregates and two different crushed stones, have been employed. The measured flatness ratios of each aggregate were 0.30, 0.36, 0.47 and 0.83, respectively. Also, the conversion shape coefficients of each aggregate were determinded as 0.77, 0.78, 0.84 and 0.92. The size of aggregate has been modified by multiplying the shape conversion coefficient and the aggregate size from DIP. The modified gradation curve with modified volume and weight of aggregate has been suggested. Within the limited test results, DIP is one of useful to get the particle shape of aggregate with limitation of measuring errors and to apply the particle distribution curve.

Comparison of Antibacterial Ability of Air Filter Media Treated with a Natural Antibacterial Agent by Three Treatment Methods (항균성 천연물질의 도포방법에 따른 에어필터 여재의 항균 특성 비교)

  • Park, Sun Young;Jung, Jae Hee;Hwang, Gi Byung;Bae, Gwi-Nam;Kim, Yong Pyo;Nho, Chu Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.125-134
    • /
    • 2013
  • Various antimicrobial technologies have been developed to inactivate bioaerosols in indoor environments. In this study, air filter media were treated with a natural antibacterial agent of Sophora flavescens in order to inactivate the bacteria collected on the air filter. Three treatment methods were applied to manufacture the test antibacterial air filter media: electrospray, nebulization and dip-coating methods. In case of electrospray and nebulization processes, the size distribution of aerosolized natural antibacterial agent was measured using a scanning mobility particle sizer. Staphylococcus epidermidis bacteria were aerosolized to test inactivation of the filter media treated with a natural antibacterial agent. The pressure drop and the antibacterial efficiency of the filter media increased with increasing the mass loading of natural antibacterial agent in each treatment method. The antibacterial efficiency per loaded antibacterial agent mass by the electrospray method was the highest and the filter treated by the dip-coating method was the lowest among three treatment methods.

Effect of Environmental Factors on the Growth, Glycogen and Hemoglobin Content of Cultured Arkshell, Scapharca broughtonii (서식환경에 따른 피조개 Scapharca broughtonii의 성장과 글리코겐 및 헤모글로빈량의 변화)

  • PARK Mi Seon;LIM Hyun Jeong;KIM Pyoung Joong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.2
    • /
    • pp.176-185
    • /
    • 1998
  • For the sustainable production of cultured arkshell Scapharca broughtonii and pre-estimation of the harvest of it, we investigated the relationship between the habitat environmental factors and the physiological conditions of the arkshell in the two experiment sites near the Chinhae Bay, Korea. For the analysis of habitat environmental factors such as temperature, salinity, dissolved oxygen, DIP (dissolved inorganic phosphate), DIN (dissolved inorganic nitrogen), suspended solids and chlorophyll a of bottom water and T-S (total sulfide) and COD (chemical oxygen demand) of surface sediment were measured, To determine physiolosical condition of cultured arkshell, shell length, fatness, glycogen, hemoglobin content and gametogenesis were examined. Water temperature were higher in Woongchon than in Songdo in 1992, and were Higher in Songdo in 1993. Salinity were higher in Songdo than in Woongchon except from January to May in 1992. COD, suspended solids and chlorophyll a content were higher in Songdo than in Woongchon, while the contents of sediment sulfide, DO, DIP and DIN were higher in Woongchon. Based on the environmental assessment, significant factors affecting the growth and physiological condition of arkshell were quantity of food and total sulfide content in the bottom sediment.

  • PDF