• 제목/요약/키워드: Dip

검색결과 1,377건 처리시간 0.031초

Investigation of Streaky Mark Defect on Hot Dip Galvannealed IF Steel

  • Xinyan, Jin;Li, Wang;Xin, Liu
    • Corrosion Science and Technology
    • /
    • 제9권3호
    • /
    • pp.109-115
    • /
    • 2010
  • Interstitial-free (IF) steels are widely used for car body material. However, a few types of streaky mark defect are commonly found on hot dip galvannealed (GA) IF steel sheets. In the present study, both the phase structure of a streaky mark defect and the microstructure of the substrate just below it were characterized by optical microscopy (OM) and scanning electron microscopy (SEM). It was found that the bright streaky mark area was composed of ${\delta}$ phase while the dark normal area was full of craters. More than half of the grains at the uppermost surface of the substrate just below the streaky mark defect are unrecrystallized grains which could result from lower finish rolling temperature during hot rolling and be kept stable during the annealing process, while almost all the grains in the normal area are equiaxed grains. In order to confirm the effect of the unrecrystallized grains on the coating morphology, hot dip galvannealing simulation experiments were carried out in IWATANI HDPS. It is proved that the unrecrystallized grains accelerate the Fe-Zn reaction rate during galvannealing and result in a flatter coating surface and an even coating thickness. Finally, a formation mechanism of the streaky mark defect on the hot dip galvannealed IF steel sheet was discussed.

한국 연안역 수질성분들(COD, DIN, DIP, Chlorophyll-a)의 해역별 농도 특성과 등급화: 통계적 접근 (Concentration Level and Grading of Water Quality Components (COD, DIN, DIP, Chlorophyll-a) in Korean Coastal Waters: A Statistical Approach)

  • 임동일;최현우;김영옥;정회수;강영실
    • Ocean and Polar Research
    • /
    • 제33권1호
    • /
    • pp.13-20
    • /
    • 2011
  • Comprehensive data collection was carried out between 2001-2006 to investigate the concentration levels of chlorophyll-a, nutrients (DIN and DIP), and COD for surface waters of Korean coastal areas. A statistical analysis of these parameters was carried out on the basis of the frequency distribution of their concentration. Furthermore, the numeric grading for chlorophyll-a, DIN, DIP, and COD concentrations were derived statistically from the normalized frequency distribution of log-transformed data. The statistical grading clearly reflects the water quality characteristics of three Korean coastal water bodies (Western, Southern and Eastern coastal zones), which indicate common environmental and ecological characteristics. So, this study could provide useful information to set up the guideline for water quality assessment of Korean coasts.

Rotating Wheel Dip Test에 의한 에폭시 절연재료의 내트래킹성과 열화 특성 (Tracking Resistance and Aging Characteristics of Epoxy Insulating Materials by the Rotating Wheel Dip Test)

  • 조한구
    • 한국전기전자재료학회논문지
    • /
    • 제21권6호
    • /
    • pp.530-537
    • /
    • 2008
  • This paper describes the results of a study on the tracking performance of outdoor insulating materials based on the rotating wheel dip test(RWDT). And, the influence of surface degradation was evaluated through such as measurement of the flashover voltage after and before tracking test, also aspects of surface degradation using scanning electron microscopy. The time to tracking breakdown of treated filled specimen is longer than untreated filled specimen. And, after the RWDT, the surface of specimen by adding untreated filler appeared heavy erosion. It was found that the addition to surface treated filler, the better tracking resistance. In the RWDT, the breakdown specimen is not affected by the dry flashover voltage, despite the fact that the surface degradation of tracking test has different state on each specimen. This suggests that wet flashover voltage play an important role in evaluating of tracking and erosion on the surface degradation in tracking test. And, the flashover voltage of specimen under wet conditions are greatly affected by the salt concentration and degree of degradation by the RWDT Because of hydrophobicity and degree of degradation by the RWDT, the flashover voltage of treated filled specimen is higher than that of untreated filled specimen. Different types of specimen may have different hydrophobicity and their surface state under contaminated conditions may not be the same.

투명전도성 막의 표면처리를 통한 계면 접촉 향상 및 재결합 방지 연구 (A study on the improvement of the contact of interface and the prevention of the charge recombination)

  • 서현웅;홍지태;손민규;김진경;신인영;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1258_1259
    • /
    • 2009
  • 염료감응형 태양전지 (dye-sensitized solar cell; DSC)는 경제성 한계에 달한 Si 태양전지를 대체할 수 있는 유력한 후보로서, 지금까지 많은 연구개발로 큰 효율향상을 기록했다. 다양한 연구 분야 중에서도, 투명전도성 막과 전해질 층간의 접촉으로 발생하는 전자의 재결합을 막기 위해 삽입하는 compact layer는 ZnO dip-coating, $TiCl_4$ dip-coating, Ti sputtering 등 다양한 제조방법이 제시되었다. 본 연구에서는 $TiCl_4$ 용액을 이용해 spin-coating 방법으로 $TiO_2$ compact layer를 제조하는 시도를 했다. 기존 dip-coating 방법과의 비교를 통해서 본 연구의 spin-coating 방법에 의한 효과를 확인한 결과, standard DSC 대비 33.4%, dip-coating 방법으로 compact layer를 삽입한 DSC 대비 6%의 효율 향상을 기록했다.

  • PDF

용융합금도금 강판 적용 노측용 방호울타리 충돌 안전성 평가 해석 사례 연구 (A Simulation Case Study on Impact Safety Assessment of Roadside Barriers Built with High Anti-corrosion Hot-dip Alloy-coated Steel)

  • 노명현
    • 한국안전학회지
    • /
    • 제31권2호
    • /
    • pp.83-89
    • /
    • 2016
  • As the world's industrial development quickens, the highways and regional expressways have been expanding to serve the logistics and transportation needs of people. The burgeoning road construction has led to a growing interest in roadside installations. These must have reliable performance over long periods, reduced maintenance and high durability. Steel roadside barriers are prone to corrosion and other compromises to their functionality. Therefore, using high anti-corrosion steel material is now seen as a viable solution to this problem. Thus, the objective of this paper is to expand the scope of applications for high anti-corrosion steel material for roadside barriers. This paper assesses the impact safety such as structural performance, occupant protection performance and post-impact vehicular response performance by a simulation review on roadside barriers built with high strength anti-corrosion steel materials named as hot-dip zinc-aluminium-magnesium alloy-coated steel. The simulation test results for the roadside barriers built with high strength anti-corrosion steels with reduced sectional thickness meet the safety evaluation criteria, hence the proposed roadside barrier made by high strength and high anti-corrosion hot-dip zinc-aluminium-magnesium alloy-coated steel will be a good solution to serve safe impact performance as well as save maintenance cost.

In Vitro Flower Abscission Induction in North American Ginseng

  • Campeau Cindy;Proctor John T. A.
    • Journal of Ginseng Research
    • /
    • 제29권2호
    • /
    • pp.71-79
    • /
    • 2005
  • In vitro studies using detached inflorescences with peduncles were conducted to investigate flower abscission agents in North American ginseng (Panax quinquefolius L.). Of the nine compounds studied only three, ammonium thiosulphate (ATS), abscisic acid (ABA) and ethephon induced abscission. Anilazine, benzyladenine, carbaryl, gibberellic acid, napthaleneacetic acid and thidiazuron did not induce abscission. ATS dip treatments did not induce abscission but the spray treatments induced $60.5\%$ abscission at $1500\;mg{\cdot}L^{-1}$ and $33.1\%$ at $3000\;mg{\cdot}L^{-1}$. Severe chlorophyll loss occurred on all inflorescences treated with ATS. Both ABA dip treatments and a $250\;{\mu}mol{\cdot}L^{-1}$ spray treatment caused abscission $(40\%)$ without adverse effects, and timing of ABA application was important. Because ABA was only significant in the dip treatments, ABA may not be a practical option for field use on ginseng. Ethephon sprays induced more abscission as the season progressed and as the concentration increased. As the dip concentrations of ethephon increased, the abscission rate decreased and the health of the inflorescences declined. The $1500\;mg{\cdot}L^{-1}$ spray of ethephon gave consistent abscission results over the glowing season with little phytotoxicity. Treatment with the competitive ethylene inhibitor 1-methylcy-clopropene (1-MCP) suggested that flower abscission was due to the liberation of ethylene from the breakdown of ethephon.

Effect of Annealed Oxides on the Formation of Inhibition Layer During Hot-Dip Galvanizing of 590Mpa Trip Steel

  • Kim, Seong-Hwan;Huh, Joo-Youl;Lee, Suk-Kyu;Park, Rho-Bum;Kim, Jong-Sang
    • Corrosion Science and Technology
    • /
    • 제10권1호
    • /
    • pp.6-12
    • /
    • 2011
  • The selective surface oxidation of a transformation-induced-plasticity (TRIP) steel containing 1.6 wt.% Mn and 1.5 wt.% Si during annealing at $800^{\circ}C$ was investigated for its influence on the formation of an inhibition layer during hot-dip galvanizing. The selective oxidation of the alloying elements and the oxide morphology were significantly influenced by the annealing atmosphere. The pure $N_{2}$ atmosphere with a dew point $-40^{\circ}C$ promoted the selective oxidation of Mn as a crystalline $Mn_{2}SiO_{4}$ phase, whereas the $N_{2}$ + 10% $H_{2}$ atmosphere with the same dew point $-40^{\circ}C$ promoted the selective oxidation of Si as an amorphous Si-rich oxide phase. During hot-dip galvanizing, the $Mn_{2}SiO_{4}$ phase was reduced more readily by Al in the Zn bath than the Si-rich oxide phase. Consequently, the pure $N_{2}$ atmosphere resulted in a higher formation rate of $Fe_{2}Al_{5}$ particles at the Zn/steel interface and better galvanizability than the $N_{2}$ + 10% $H_{2}$ atmosphere.

암반사면의 전도파괴에 대한 안정해석 (Stability Analysis of Toppling Failure in Rock Slopes)

  • 이명재;이인모
    • 한국지반공학회지:지반
    • /
    • 제14권2호
    • /
    • pp.55-66
    • /
    • 1998
  • 본 논문의 목적은 불연속면의 공학적 특성, 사면형상과 하중조건 등을 고려한 암반사면 전도 파괴에 대한 안정해석방법을 개발하고 적용하는테 있다. 암반사면의 전도파괴에 대한 안정은 경사각 $\alpha_s$ 와 H/t비에 주된 영향을 받는다. 설계적용을 위하여 매개변수에 따른 My띠와 $\alpha$서 함수로 표현되는 암반사면 전도파괴에 대한 안정도표를 작성하였다. 안정도표에서 $\alpha_s$와 Hy띠가 작아질수록 안정성이 증가하는 경향을 보인다. 안정도표에서 안정영역은 간극수압변화에 따라 가장 크게 감소한다. 파괴영역의 변화는 지진력과 단계각에 가장 민감하다.

  • PDF

3D numerical investigation of segmental tunnels performance crossing a dip-slip fault

  • Zaheri, Milad;Ranjbarnia, Masoud;Dias, Daniel
    • Geomechanics and Engineering
    • /
    • 제23권4호
    • /
    • pp.351-364
    • /
    • 2020
  • This paper numerically investigates the effects of a dip-slip fault (a normal or a reverse fault) movement on a segmental tunnel which transversely crosses either of this kind of faults. After calibration of the numerical model with results from literature of centrifuge physical tests, a parametric study is conducted to evaluate the effects of various parameters such as the granular soil properties, the fault dip angle, the segments thickness, and their connections stiffnesses on the tunnel performance. The results are presented and discussed in terms of the ground surface and tunnel displacements along the longitudinal axis for each case of faulting. The gradient of displacements and deformations of the tunnel cross section are also analyzed. It is shown that when the fault dip angle becomes greater, the tunnel and ground surface displacements are smaller, in the case of reverse faulting. For this type of fault offset, increasing the tunnel buried depth causes tunnel displacements as well as ground surface settlements to enhance which should be considered in the design.

Hydrogen Permeation of SiC-CeO2 Composite Membrane by Dip-coating Process

  • Park, Jihye;Jung, Miewon
    • 한국세라믹학회지
    • /
    • 제50권6호
    • /
    • pp.485-488
    • /
    • 2013
  • A SiC-$CeO_2$ composite membrane was successfully fabricated using an ally-hydridopolycarbosilane (AHPCS) binder and treated by dip-coating at 60 times with a $CeO_2$ sol solution. The dip-coated SiC membrane was calcined at 773 K and then sintered at 1173 K under an air atmosphere. The coated membrane was characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FE-SEM) and a BET surface analysis. The difference in permeation performance between $H_2$ and CO gases was measured by varying the temperature. The permeation flux of $H_2$ on the SiC membrane with layered $CeO_2$ was obtained as $8.45{\times}10^{-6}\;mol/m^2sPa$ at room temperature. The CO permeation flux was $2.64{\times}10^{-6}\;mol/m^2sPa$ at room temperature. The reaction enthalpy (${\Delta}H^{\circ}$) for the hydrogen permeation process was calculated as -7.82 J/mol by Arrhenius plots.