• Title/Summary/Keyword: Dip

Search Result 1,377, Processing Time 0.027 seconds

Water Quality Simulation of the Reservoir Using Ecological Model

  • Kim, Dong-Myung;Suk, Ji-Won;Kim, Sun-Young;Shin, Sang-Ik;Roh, Kyong-Joon
    • Journal of Environmental Science International
    • /
    • v.23 no.10
    • /
    • pp.1755-1762
    • /
    • 2014
  • Water quality of the Koejong-reservoir was estimated by using the ecological model to evaluate the effects of industrial sewage discharge. State variables consist of POC, DOC, phytoplankton, DIP, DIN, DO and COD. Initial conditions for the compartment are applied to the model based on the observed results. The reproducibility was found to be satisfactory with the relative error ranging between the calculated value and the observed value. Water quality simulation was conducted by applying additional industrial sewage discharge into the Koejong-reservoir. The concentrations of COD, Chl.a, DIP and COD showed fluctuations of a narrow range. The increment percentages of Chl.a, COD and DIP were 26.6%, 20.2% and 18.2%, respectively. In the case of DO, the concentration decreased 4.8%.

The Effect of Location of an Ingested Source in a Human Body Model on Electromagnetic Propagation

  • Jung, Ji-Hyun;Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.1
    • /
    • pp.51-55
    • /
    • 2011
  • Electromagnetic fields, radiated from an intestine-ingested source and propagated through an inhomogeneous human body model, are computed with the finite-difference time-domain (FDTD) method. The calculated results obtained at some receiving points vertically placed according to the abdomen of the human body model show unusual dip patterns in the frequency domain. The frequency of this unusual dip varies according to the location of the receiving points. Thus, the relationship between the frequency of the unusual dip and the incident angle of the line-of-sight is analyzed. The effect of the location of an ingested source on the above relationship is also investigated. The slope of the approximately linear relationship is affected by the location of the ingested source.

Preparation and Characterization of Porous Low Reflective Coating Films for $SiO_2.ZrO_2$ System by Sol-Gel Dip-Coating Method (졸-겔 침지법에 의한 $SiO_2.ZrO_2$계 다공질 저반사 코팅막 제조 및 특성)

  • 김상진;한상목;신대용;김경남
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.7
    • /
    • pp.774-780
    • /
    • 1997
  • Porous low reflective coating films of SiO2.ZrO2 system were prepared from the mixed alkoxide solutions of Zr(O-nC3H7)4 and partially prehydrolyzed TEOS by the sol-gel method using the dip-coating technique. In the case of 90SiO2.10ZrO2 porous coating films with HCl and H2O content was 0.3 mole and 4 mole, 378 m2/g of the specific surface area, 0.254 cm3/g of total pore volume, 30-50$\AA$ of average pore diameter. The transmittance of 90SiO2.10ZrO2 porous coated films was 95.38% at the wavelength of 550 nm, compared with the parent glass, the transmittance was increased with 4.38%.

  • PDF

Performance of Hot-dip Zn-6%Al-3%Mg Alloy Coated Steel Sheet as Automotive Body Material

  • Shimizu, Takeshi;Asada, Hiroshi;Morikawa, Shigeru
    • Corrosion Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.74-80
    • /
    • 2010
  • For the purpose of applying a hot-dip Zn-6mass%Al-3mass%Mg alloy coated steel sheet (ZAM) to automotive body materials, a laboratory study of the general properties required for inner and outer panels of automotive bodies was performed. Even with only light coating weight, ZAM showed an excellent corrosion resistance in terms of both cosmetic and perforation corrosion compared to the currently used materials for automotive bodies, GI70 and GA45. In our study, it was confirmed that ZAM exhibits as good as or better properties than GI70 in terms of spot weldability and press formability. Furthermore, since the same corrosion resistance can be achieved with less coating weight by applying ZAM, laser weldability is better than GI and GA.

Design of surface plasmon resonance sensors using evolution algorithm (진화알고리즘을 이용한 표면플라즈몬 공명센서의 설계)

  • Jung, Jae-Hoon;Kim, Min-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1615-1616
    • /
    • 2006
  • 본 논문에서는 표면 플라즈몬 공명(Surface Plasmon Resonance) 센서의 여러 파라미터를 동시에 만족시키는 설계기법을 제시하였다. 설계 파라미터는 반사광 dip의 3dB bandwidth와 dip의 깊이이고 목적함수는 해석치와 목표치의 차이 벡터의 norm으로 정의하였다. 설계 변수는 박막된 각 금속 충의 두께로 하였고 SPR 센서의 스펙트럼을 해석하기 위해 광학 어드미턴스 기법을 이용하였다. 최적화 기법은 (1+1) 진화 알고리즘을 사용하였다. 설계방법을 3층 구조의 SPR 센서에 적용하여 최적 설계한 파라미터는 초기값에 비해 3dB bandwidth는 4.8nm, dip의 깊이는 1.1dB 향상되었다.

  • PDF

Controlling Zero Sequence Component in DVR for Compensating Unbalanced Voltage Dip of a DFIG

  • Ko, JiHan;Thinh, Quach Ngoc;Kim, SeongHuyn;Kim, Eel-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.154-155
    • /
    • 2012
  • The dynamic voltage restorer (DVR) is an effective protection device for wind turbine generator based on doubly-fed induction generator (DFIG) operated under the unbalanced voltage dip conditions. The compensating voltages of DVR depend on the voltage dips and on the influence of the zero sequence components. If the $Y_0/{\Delta}$ step-up transformers are used, there are no zero sequence components on the DFIG side. However, if the $Y_0/Y_0$ step-up transformers are used, the zero sequence components will appear during faults. The zero sequence components result in the high insulation costs and the asymmetric of the terminal voltages. This paper proposes a method for controlling zero sequence components in DVR to protect DFIG under unbalanced voltage dips. Simulation results are presented to verify the effectiveness of the proposed control method.

  • PDF

Design and Fabrication of Dual Tip Si3N4 Probe for Dip-pen Nanolithograpy (Dip-pen nanolithography를 위한 이중 팁을 가진 질화규소 프로브의 설계 및 제조)

  • Kim, Kyung Ho;Han, Yoonsoo
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.6
    • /
    • pp.362-367
    • /
    • 2014
  • We report the design, fabrication of a $Si_3N_4$ probe and calculation of its mechanical properties for DPN(dip pen nanolithography), which consists of dual tips. Concept of dual tip probe is to employ individual tips on probe as either an AFM tip for imaging or a writing tip for nano patterning. For this, the dual tip probe is fabricated using low residual stress $Si_3N_4$ material with LPCVD deposition and MEMS fabrication process. On the basis of FEM analysis we show that the functionality of dual tip probe for imaging is dependent on the dimensions of dual tip probe, and high ratio of widths of beam areas is preferred to minimize curvature variation on probe.

Deformation of Tunnel Affected by Adjacent Slope Excavation in a Joint Rock Mass (절리암반사면 굴착시 기존터널의 변형특성)

  • Lee, Jin-Wook;Lee, Sang-Duk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.891-896
    • /
    • 2008
  • Behavior of the existing tunnel in the jointed rocks was affected by the adjacent slope excavation. In this study, large scale model tests were conducted. To investigate the tunnel distortion depending on the excavated slope angle and the joint dip of the ground performed model tests were numerically back analyzed. Consequently, as the joint dip and slope angle became larger, the tunnel distortion was tended to be larger. Ground displacement was also greatly dependent on the joint dip and the excavated slope angle, which indicated the possibility of the optimal slope reinforcement.

  • PDF

Empirical Study on the Dip Design and Installation of Distribution Line Conductors (배전선로의 이도설계 및 시공에 대한 실증연구)

  • Ahn, Ihn-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.3
    • /
    • pp.307-313
    • /
    • 2021
  • In this study, the comparative analysis, among the design standard value of distribution power, the calculated value from the measurement data of strand and the empirical data of the distribution line itself, have been performed for the elastic coefficients and linear expansion coefficients of distribution line conductors. The empirical values of elastic coefficients were lower about 10.6%(892kgf/mm2) than those of the design standard value of the distribution power and there were a little difference between the empirical values of linear expansion coefficients and the design standard value of the distribution power. From the above results, it could be concluded that the empirical values of conductor characteristics should be used in the dip design and installation of distribution line.

On the Near Wall Coating Flow in a Sloshing Flow of Highly-Viscous Fluid in a Rectangular Box (사각용기의 고점성 슬로싱 유동에서 발생하는 측벽 코팅 유동)

  • Jun Sang, Park
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.27-35
    • /
    • 2022
  • A problem on the sloshing flow of highly-viscous fluid in a rectangular box was revisited by both of theoretical approach and experimental visualization method. Based on the theoretical prediction that a linear shape of free surface is prevailing in bulk zone, it has been studied an analogy between a near wall coating flow in sloshing problem and dip coating flow in Landau-Levich problem. Phenomenological observation confirms that, in the case of highly-viscous fluid, I.e., Re ≪ 1, viscous dominant near-wall flow in sloshing problem is identical to dip coating flow generated by drag-out of the plate being in both motion of vertical translation and horizontal rotation.