The Effect of Location of an Ingested Source in a Human Body Model on Electromagnetic Propagation  

Jung, Ji-Hyun (Korea Institute of Science and Technology)
Kim, Se-Yun (Korea Institute of Science and Technology)
Publication Information
Abstract
Electromagnetic fields, radiated from an intestine-ingested source and propagated through an inhomogeneous human body model, are computed with the finite-difference time-domain (FDTD) method. The calculated results obtained at some receiving points vertically placed according to the abdomen of the human body model show unusual dip patterns in the frequency domain. The frequency of this unusual dip varies according to the location of the receiving points. Thus, the relationship between the frequency of the unusual dip and the incident angle of the line-of-sight is analyzed. The effect of the location of an ingested source on the above relationship is also investigated. The slope of the approximately linear relationship is affected by the location of the ingested source.
Keywords
Capsule Endoscope; Electromagnetic Propagation; FDTD; Human Body;
Citations & Related Records
연도 인용수 순위
  • Reference
1 W. G. Scanlon, J. B. Burns, and N. E. Evans, "Radiowave propagation from a tissue-implanted source at 418 MHz and 916.5 MHz," IEEE Trans. Biomed. Eng., vol. 47, pp. 527-534, Apr. 2000.   DOI   ScienceOn
2 L. C. Chirwa, P. A. Hammond, S. Roy, and D. R. S. Cumming, "Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz," IEEE Trans. Biomed. Eng., vol. 50, pp. 484-492, Apr. 2003.   DOI   ScienceOn
3 A. Alomainy, Y. Hao, "Modeling and characterization of biotelemetric radio channel from ingested implants considering organ contents," IEEE Trans. Antennas Propag., vol. 57, no. 4, pp. 999-1005, Apr. 2009.   DOI   ScienceOn
4 J.-H. Jung, S.-W. Kim, Y.-S. Kim, and S.-Y. Kim, "Electromagnetic propagation from the intestine-ingested source in the human body model," IEEE Trans. Antennas Propag., vol. 58, no. 4, pp. 1683-1688, May 2010.   DOI   ScienceOn
5 X. Wang, M. Q.-H. Meng, and Y. Chan, "A lowcost tracking method based on magnetic marker for capsule endoscope," in Proc. Int. Conf. on Information Acquisition, pp. 524-526, 2004.
6 A. Taflove, S. C. Hagness, Computational Electrodynamics: The Finite-Difference Time-Domain Method, Norwood, MA: Artech, 2000.
7 J. P. Berenger, "A perfectly matched layer for the absorption of electromagnetic waves," J. Comput. Phys., vol. 114, pp. 185-200, Oct. 1994.   DOI   ScienceOn
8 G. Iddan, G. Meron, A. Glukhovsky, and P. Swain, "Wireless capsule endoscopy," Nature, vol. 405, p. 417, May 2000.
9 D. Fischer, R. Schreiber, D. Levi, and R. Eliakim, "Capsule endoscopy: the localization system," Gastrointest. Endos. Clinics North Amer., vol. 14, pp. 25-31, 2004.   DOI   ScienceOn
10 K. Tai, H. Harada, and R. Kohno, "Channel modeling and signaling of medical implanted communication systems and a step to medical ICT," presented at the Mobile and Wireless Communications Summit, 2007.
11 Y. Chan, M. Q.-H. Meng, K.-L. Wu, and X. Wang, "Experimental study of radiation efficiency from an ingested source inside a human body model," in Proc. 27th IEEE Engineering in Medicine and Biology, Shanghai, pp. 7754-7757, 2005.