• Title/Summary/Keyword: Dioxide nitrogen

Search Result 549, Processing Time 0.03 seconds

Molecular Structure of PCP Pincer Complexes: Poisoning Catalyst on the Dehydrogenation of Alkanes (알칸의 탈수소화반응에서의 촉매독 화합물의 분자구조)

  • Lee Ji Hyun;Chun Sang Jin;Kwon Ki Hyeok;Lee Do Weon
    • Korean Journal of Crystallography
    • /
    • v.16 no.1
    • /
    • pp.43-53
    • /
    • 2005
  • The dihydrido P-C-P pincer complex, $IrH_2{C_6H_3-2,6-(CH_2PBu_2^t)_2}$ (1), was successfully prepared from the reaction of the hydrochloride complex, $IrClH (C_6H_3-2,6-(CH_2PBu_2^t)_2}$, and super acid $(LiBEt_3H)$ under 1 atm of hydrogen in pentane solution at room temperature and followed by Heating at $130^{\circ}C$ in vacuo. Jensen recently found that the dihydrido P-C-P pincer complex 1 is a highly active homogeneous catalyst for the transfer dehydrogenation of alkanes with unusual longterm stability at temperatures as high as $200^{\circ}C$. The treatment of dihydrido complex 1 with nitrogen, water, carbon dioxide, and carbon monoxide in presence of tert-butylethylene (the) at room temperature in an appropriate solution gave the dinitrogen complex, $[Ir{C-6H_3-2,6-(CH_2PBu_2^t)_2}]_2({\mu}-N_2)$ (2), the hydrido hydroxyl complex, $IrH(OH){C_6H_3-2,6-(CH_2PBu_2^t)_2}$ (3), the carbon dioxide complex, $Ir({\eta}^2-CO_2) {C_6H_3-2,6-(CH_2PBu_2^t)_2}$ (including the bicarbonate complex, $IrH({\kappa}^2-O_2COH){C_6H_3-2,6-(CH_2PBu_2^t)_2}\;(4))$, and the carbonyl complex, $Ir(CO) {C_6H_3-2,6-(CH_2PBu_2^t)_2}\;(5)$ (including the carboxyl complex, $IrH(C(O)OH) {C_6H_3-2,6-(CH_2PBu_2^t)_2}\;(6))$, in good yield, respectively. These P-C-P iridium complexes were isolated and characterized by $^1H,\;^{13}C,\;^{31}P\; NMR$, and IR spectroscopy. In addition, the complexes (1-6) were characterized by a single crystal X-ray crystallography. These complexes account for these small molecules' inhibition of dehydrogenation of alkanes catalyzed by the dihydrido complex 1.

A Meta-Analysis of Air Pollution in Relation to Daily Mortality in Seven Major Cities of Korea, 1998-2001 (메타분석을 적용한 전국 7개 대도시의 대기오염과 일일사망발생의 상관성 연구(1998년$\sim$2001년))

  • Cho, Yong-Sung;Lee, Jong-Tae;Son, Ji-Young;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.304-315
    • /
    • 2006
  • This study is performed to reexamine the association between ambient air pollution and daily mortality in seven major cities of Korea using a method of meta-analysis with the data filed for the period 1998-2001. These cities account for half of the Korean population (about 23 million). The observed concentrations of carbon monoxide (CO, mean=1.08 ppm), ozone ($O_3$, mean=33.97 ppb), particulate matter less than 10 ${\mu}m$ ($PM_{10},\;mean=57.11\;{\mu}g/m^3$), nitrogen dioxide ($NO_2$, mean=25.09 ppb), and sulfur dioxide ($SO_2$, mean=9.14 ppb) during the study period were at levels below Korea's current ambient air quality standards. Generalized additive models were applied to allow for the highly flexible fitting of seasonal and long-term time trends in air pollution as well as nonlinear associations with weather variables, such as air temperature and relative humidity. Also, we calculated a weighted mean as a meta-analysis summary of the estimates and its standard error. In city-specific analyses, an increase of $41.17{\mu}g/m^3(IQR)\;of\;PM_{10}$ corresponded to $1{\sim}12%$ more deaths, given constant weather conditions. Like most of air pollution epidemiologic studies, this meta-analysis cannot avoid fleeing from measurement misclassification since no personal measurement was taken. However, we can expect that a measurement bias be reduced in district-specific estimate since a monitoring station is better representative of air quality of the matched district. Significant heterogeneity was found for the effect of all pollutants. The estimated relative risks from meta-like analysis increased compared to those relative risks from pooled analysis. The similar results to those from the previous studies indicated existence of health effect of air pollution at current levels in many industrialized countries, including Korea.

Adsorption Characteristics of Flue Gas Components on Zeolite 13X and Effects of Impurity (제올라이트 13X에 의한 배가스 성분의 흡착 특성 및 불순물의 영향)

  • Suh, Sung-Sup;Lee, Ho-Jin
    • Korean Chemical Engineering Research
    • /
    • v.54 no.6
    • /
    • pp.838-846
    • /
    • 2016
  • Most of combustion processess used in industries require recovering or removing flue gas components. Recently a new MBA (moving bed adsorption) process for recovering $CO_2$ using zeolite 13X was developed. In this study, adsorption experiments for carbon dioxide, nitrogen, sulfur dioxide, and water vapor on zeolite 13X were carried out. Adsorption equilibrium and adsorption rate into solid particle were investigated. Langmuir, Toth, and Freundlich isotherm parameters were calculated from the experiment data at various temperatures. Experimental results were consistent with the theoretically predicted values. Also $CO_2$ adsorption amount was measured under the conditions with impurities such as $SO_2$ and $H_2O$. Binary adsorption data were well fitted to the extended Langmuir isotherm using parameters obtained from pure component experiment. However, $H_2O$ impurity less than, roughly, ${\sim}10^{-5}H_2O\;mol/g$ zeolite 13X enhanced slightly $CO_2$ adsorption. Spherical particle diffusion model well described experimentally measured adsorption rate. Diffusion coefficients and activation energies of $CO_2$, $SO_2$, $N_2$, $H_2O$ were obtained. Diffusion coefficients of $CO_2$ and $SO_2$ decreased with small amount of preadsorbed impurity. Parameter values from this study will be helpful to design of real commercial adsorption process.

Analysis of Potential on Measurement of SO2 and NO2 using Radiative Transfer Model and Hyperspectral Sensor (복사전달모델과 초분광센서를 이용한 아황산가스와 이산화질소의 농도 측정 가능성 분석)

  • Shin, Jung-il;Kim, Ik-Jae;Choi, Min-Jae;Lim, Seong-Ha
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.658-663
    • /
    • 2018
  • Current measuring methods for air quality are based on ground measurement networks and satellite data. New methods of collecting evidence with advanced sensors are needed because current methods have limitations in collecting evidence for the illegal emission of air pollutants at narrow areas or specific sites. This study analyzed the possibility of using an ultraviolet hyperspectral sensor to measure the concentration of nitrogen dioxide and sulfur dioxide. Two types of spectra were used: simulated spectra for gases with various concentrations using a radiative transfer model and observed spectra for each gas for a concentration. To understand the possibility of using a hyperspectral sensor, the differences between the simulated spectra and the observed spectra were analyzed, and the variation of simulated spectra were then analyzed according to the concentration. The results showed good agreement between observed spectra and simulated spectra. In addition, the absorption depth at specific wavelengths in the simulated spectra had a very strong correlation with the gas concentration. The gas concentration could be estimated using the hyperspectral sensor. In the future, validation would be needed to estimate the gas concentration through observations of various concentrations of gases using a hyperspectral sensor.

Comparative Study on the Efficiency Test Using Remodeled Bubble Generating Pump for Aquarium Fish and Established Air Sampling Pump (관상어용 기포발생기를 개조한 시료채취 장치와 기존의 시료채취기와의 성능 비교)

  • Jang, Bong-Ki;Chun, Jae-Young;Son, Bu-Soon;Lee, Jong-Wha;Park, Jong-An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.183-191
    • /
    • 2005
  • This study is designed to compare the performance of established samplers (personal air sampler and MiniVOL portable air sampler) commonly used in the air environment or work environment with that of the sampler made by remodeling the air bubble generator for aquarium fishes. Sampling method used in this study is the filter collection method for PM10 and total suspended particles (TSP), the liquid collection method for sulfur dioxide ($SO_2$) and nitrogen dioxide ($NO_2$), and the solid collection method for toluene, respectively. There is not a significant difference in the average concentration of TSP between the Gilian personal air sampler (1st, $0.316{\pm}0.095$; 2nd $0.191{\pm}0.090$; 3rd, $0.185{\pm}0.073mg/m^3$) and the remodeled sampler (1st, $0.317{\pm}0.106$, 2nd $0.201{\pm}0.050$; 3rd $0.189{\pm}0.081mg/m^3$). There are also not significant differences in the average concentration of PM10 among the Gilian personal air sampler ($0.058{\pm}0.006mg/m^3$), the remodeled sampler ($0.052{\pm}0.008mg/m^3$) and the MiniVOL portable air sampler ($0.054{\pm}0.007mg/m^3$). The average concentration of the SO2 by the established sampler and the remodeled one is $3.79{\pm}0.21ppb$ and $3.45{\pm}0.15ppb$, respectively. In addition, there are not sigmficant differences in the average concentration of the NO2 between the Gilian personal air sampler (1st, $0.325{\pm}0.068$; 2nd $0.341{\pm}0.206$; 3rd, $2.971{\pm}0.078{\mu}g/m^3$) and the remodeled sampler (1st, $0.300{\pm}0.062$; 2nd $0.332{\pm}0.144$, 3rd, $2.968{\pm}0.085{\mu}g/m^3$). There are not significant differences in the average concentration of toluene between the Gilian personal air sampler (1st, $0.499{\pm}0.072$; 2nd $0.598{\pm}0.112$; 3rd $2.284{\pm}0.077{\mu}g/m^3$) and the remodeled sampler (1st, $0.463{\pm}0.133$; 2nd $0.603{\pm}0.082$; 3rd $2.353{\pm}0.115{\mu}g/m^3$). From these results, we can conclude that the performance of the remodeled sampler is not different from that of established samplers. There is possibility that the remodeled sampler can be used as a alternative device for Gilian personal air sampler in area and personal air sampling.

Concentration of $NO_2$ and $SO_{2}$ of Bus Terminals in Seoul (서울시 버스터미널의 이산화질소 및 아황산가스 농도)

  • 손부순;장봉기;김영규
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.51-59
    • /
    • 1997
  • In this study, we researched the concentration of nitrogen dioxide($NO_{2}$) and sulfur dioxide($SO_{2}$) of indoor(waiting room) and outdoor(place of getting on the bus) at the bus terminals (Kang-Nam, Dong-Seoul and Nam-Bu) in Seoul to recognize the degree of pollution by exhaust gas of the diesel engine vehicles, and examine the factor that might affect air pollution of terminals. The concentration of $NO_{2}$ and $SO_{2}$ were measured in winter and summer, and the results of the analysis are as follows : The mean concentration of $NO_{2}$ was $57.49{\pm}21.86$ ppb and the concentration of outdoor with $64.10{\pm}27.69$ ppb was significantly higher than the indoor with $50.89{\pm}10.92$ ppb (p<0.05), and the highest with $73.54{\pm}25.54$ ppb at Kang-Nam terminal (p<0.01). The mean concentration of $NO_{2}$ was $62.80{\pm}24.74$ ppb in winter and $52.19{\pm}17.50$ ppb in summer, and had a not statistical difference. The mean concentration of $SO_{2}$ was $31.71{\pm}8.73$ ppb and the concentration of outdoor with $31.04{\pm}8.89$ ppb was similar to the indoor $32.29{\pm}8.70$ ppb, and the highest with $32.57{\pm}9.01$ ppb at Dong-Seoul terminal (p<0.05). The mean concentration of $SO_{2}$ in winter with $39.67{\pm}4.10$ ppb was significantly higher than in summer with $23.76{\pm}2.61$ ppb (p<0.01). The concentration of outdoor $NO_{2}$ at Kang-Nam terminal was 104, 84 ppb in winter and 81.20 ppb in summer, and had a statistical difference compared with the concentration of indoor $NO_{2}$ at Dong-Seoul and Nam-Bu terminals. The concentration of indoor $NO_{2}$ and $SO_{2}$ were higher than that of outdoor at Kang-Nam and Dong-Seoul terminals, but on the contrary, lower than that of outdoor at Nam-Bu terminal. The concentration of $NO_{2}$ and $SO_{2}$ at Nam-Bu terminal were lower than those at Kang-Nam and Dong-Seoul terminals. While the concentration of $SO_{2}$ show the large difference between winter and summer, that of $NO_{2}$ dose not.

  • PDF

Process Optimization of PECVD SiO2 Thin Film Using SiH4/O2 Gas Mixture

  • Ha, Tae-Min;Son, Seung-Nam;Lee, Jun-Yong;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.434-435
    • /
    • 2012
  • Plasma enhanced chemical vapor deposition (PECVD) silicon dioxide thin films have many applications in semiconductor manufacturing such as inter-level dielectric and gate dielectric metal oxide semiconductor field effect transistors (MOSFETs). Fundamental chemical reaction for the formation of SiO2 includes SiH4 and O2, but mixture of SiH4 and N2O is preferable because of lower hydrogen concentration in the deposited film [1]. It is also known that binding energy of N-N is higher than that of N-O, so the particle generation by molecular reaction can be reduced by reducing reactive nitrogen during the deposition process. However, nitrous oxide (N2O) gives rise to nitric oxide (NO) on reaction with oxygen atoms, which in turn reacts with ozone. NO became a greenhouse gas which is naturally occurred regulating of stratospheric ozone. In fact, it takes global warming effect about 300 times higher than carbon dioxide (CO2). Industries regard that N2O is inevitable for their device fabrication; however, it is worthwhile to develop a marginable nitrous oxide free process for university lab classes considering educational and environmental purpose. In this paper, we developed environmental friendly and material cost efficient SiO2 deposition process by substituting N2O with O2 targeting university hands-on laboratory course. Experiment was performed by two level statistical design of experiment (DOE) with three process parameters including RF power, susceptor temperature, and oxygen gas flow. Responses of interests to optimize the process were deposition rate, film uniformity, surface roughness, and electrical dielectric property. We observed some power like particle formation on wafer in some experiment, and we postulate that the thermal and electrical energy to dissociate gas molecule was relatively lower than other runs. However, we were able to find a marginable process region with less than 3% uniformity requirement in our process optimization goal. Surface roughness measured by atomic force microscopy (AFM) presented some evidence of the agglomeration of silane related particles, and the result was still satisfactory for the purpose of this research. This newly developed SiO2 deposition process is currently under verification with repeated experimental run on 4 inches wafer, and it will be adopted to Semiconductor Material and Process course offered in the Department of Electronic Engineering at Myongji University from spring semester in 2012.

  • PDF

Quality Changes of Chicken Breast Meat by Slow-Released ClO2 Gas Gel-Pack during Storage (서방형 이산화염소 가스 젤팩을 이용한 닭가슴육 저장 중 품질 변화)

  • Lee, Kyung-Haeng;Yoon, Ye-Ji;Kwon, Hye-Won;Lee, Bom;Kim, Hong-Gil
    • The Korean Journal of Food And Nutrition
    • /
    • v.31 no.1
    • /
    • pp.127-134
    • /
    • 2018
  • To prolong the shelf-life of chicken breast meat, samples were treated with gel packs containing slow-released chlorine dioxide ($ClO_2$) gas at 7~15 ppm for eight days at $4^{\circ}C$. The microbial, physicochemical properties and sensory evaluation of the treated samples were investigated. The total number of bacteria in the control increased during storage and showed 6.78 log CFU/g on the 8th day of storage, but $ClO_2$ gas treatments showed 6.24~6.58 log CFU/g at the same time. The initial pH of chicken breast meat was 6.00 and gradually increased during storage. And $ClO_2$ gas treatments did not show any significant difference from the control during storage period, but maintained a generally lower pH than that of the control. The lightness, redness, and yellowness during storage were not significantly different between the control and the 7~10 ppm $ClO_2$ gas treatments. However, as the storage period was increased, the redness of 15 ppm $ClO_2$ gas treatment was reduced. The cooking loss and shear force were not different between the control and $ClO_2$ gas treatments during the storage period. Volatile basic nitrogen (VBN) increased in the control from the 6th day of storage and 23.80 mg% in the 8th day of storage. However, VBN of $ClO_2$ treatments showed lower than that of the control. In the change of sensory evaluation during storage, 10 ppm $ClO_2$ treatment showed the highest preference in odor, appearance and overall acceptance during storage period.

Adverse Effects of the Megadose Perilla Oil on the Rats Metabolism (들깨기름을 다량 투여한 흰쥐에서 대사에 미치는 역작용에 관하여)

  • 서화중;서유승
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.2
    • /
    • pp.277-283
    • /
    • 2002
  • In the present study, adverse effects of megadose of dietary perilla oil were investigated in an experimental model consisted of 6 groups of Wistar rats. To compare the adverse effects of megadose perilla oil with different kind of dietary fat, rats were fed one of the following diets for one month: 10% beef tallow (B$_1$B), 10% corn oil (C$_1$B), 10% perilla oil (P$_1$B), 20% beef tallow (B$_2$B), 20% corn oil (C$_2$B), and 20% perilla oil (P$_2$B) diet. The body weight gain rate seemed to be more affected by the size of fat contents than the species of fat in the diet, so the body weight gain rate of 20% fat groups were significantly higher than those of 10% fat groups in spite of the larger amount of flood intake in 10% fat groups than in 20% fat groups. The levers of plasma triglyceride and total-cholesterol in 20% fat groups were significantly increased in dose dependent fashion when compared to 10% groups, the values of beef tallow (B$_2$B) group being the highest among all groups. Plasma glutainic pyruvic transferase activities and level of blood urea nitrogen had a tendency to increase along with increase of fat contents (%) in diets, the values of P$_2$B group, the highest among all groups, being beyond the normal levers. The plasma carbon dioxide concentration of P$_2$B group was the highest in all groups and exceeded the normal value, there being no significant difference among the plasma carbon dioxide concentration of others groups. The results showed that large dose and long term intake of dietary perilla oil had some adverse effects on hepatic and other organic functions in rats.

Characteristics of indoor air quality in the overground and underground railway stations (지상과 지하역사의 실내공기질 특성과 외기영향 평가)

  • Namgung, Hyeong-Kyu;Song, Ji-Han;Kim, Soo-Yeon;Kim, Hee-Man;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, the air quality of underground and overground railway stations was evaluated focusing on the degree of influence of the outside air quality. The measured components were particulate matter ($PM_{10}$), carbon dioxide ($CO_2$), carbon monoxide (CO), nitrogen dioxide ($NO_2$), formaldehyde (HCHO), ozone ($O_3$), total airborne bacteria (TAB), total volatile organic carbon (TVOC), and Radon (Rn), which are included in the maintenance standards and recommended standards of the Indoor Air Quality Management Act. Also, the indoor/outdoor concentration ratios of $PM_{10}$, $NO_2$, and $O_3$ were calculated to estimate the influence of the outdoor air quality. The concentrations of $PM_{10}$ HCHO, TVOC, $NO_2$, and Rn in the underground stations were found to be higher than those in the overground stations. These results indicate that the (present) generation of contaminants are caused by the indoor source of the underground station. The ozone concentration of the overground stations was higher than that of the underground stations, which indicates that the outdoor ozone concentration influenced that of the overground stations directly. Thus, methods of improving the IAQ should take into consideration the types of contamination.