• Title/Summary/Keyword: Diode array detector

Search Result 111, Processing Time 0.026 seconds

Pharmacokinetic Analysis of Levofloxacin in Healthy Korean Volunteers

  • Kim, Seung-Yong;Chung, Youn-Bok;Pyo, Hee-Soo;Kwon, Oh-Seung
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.4
    • /
    • pp.235-240
    • /
    • 2008
  • A sensitive and simple method of determining the plasma levofloxacin (LFX, CAS 100986-85-4) concentrations in human volunteers by liquid-liquid extraction were developed and validated by using a high-performance liquid chromatography/diode array detector. The method was also applied to pharmacokinetic study of LFX. LFX was orally administered to 8 healthy male Korean volunteers at single lowest dose of 200 mg, compared to the published reports in which more than 500 mg of LFX was orally administered. LFX in human plasma was determined. The detection limit of LFX was $0.05\;{\mu}g/mL$. $C_{max}$ value was $2.48{\pm}0.67\;{\mu}g/mL$. $AUC_{0{\to}24\;hr$} and $AUC_{0{\to}{\infty}}$ were $14.52{\pm}3.35\;{\mu}g/mL$ and $16.00{\pm}3.66\;{\mu}g{\cdot}hr/mL$, respectively. The terminal half-life was $6.87{\pm}0.46\;hr$. Our pharmacokinetic parameters were very consistent with that previously reported, showing good correlation between LFX doses and AUC ($r^2=0.995$). This method can be useful for the pharmacokinetics and bioequivalence study with relatively low dose for reducing the main side effects of LFX.

A Study on the Amendment Scheme of Ginsenoside Content Standard Regulation for Red Ginseng Products in Korea (홍삼가공품의 Ginsenoside 함량 규격기준 개선방안 연구)

  • Kim, Ho Jin;Kwak, In Ae;Kim, Hyun Jung;Ahn, Jong Sung;Son, Young Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.24-30
    • /
    • 2013
  • Red ginseng is a widely used dietary supplement and medicinal herb, and there are so many forms of ginseng products including tea, extract, capsule and jelly. The purpose of the present study was to propose some amendments on ginsenoside content of red ginseng products in Korea. For this purpose, we analyzed red ginseng products for simultaneous determination of 26 ginsenosides by ultra performance liquid chromatography with diode array detector. Some developmental aspects of Korea's ginsenoside content standard regulations for red ginseng products are needed to be examined as follows : Firstly, we proposed that four ginsenosides ($Rb_1$, $Rg_1$, Rf and $Rg_3$) would be detected in red ginseng products. Secondly, in case of red ginseng extracts, the sum of $Rb_1$, $Rg_1$ and $Rg_3$ would be 4.0 mg/g. The two proposals are helpful to comprehensive evaluation of quality of red ginseng products. In conclusion, the scientific studies on amendment scheme of ginsenoside content standard regulation of red ginseng product are very important to fortify quality control.

Simultaneous Determination of Dictamine, Obacunone and Fraxinellone in Dictamnus dasycarpus cortex by HPLC-DAD (HPLC-DAD를 이용한 백선피의 Dictamine, Obacunone, Fraxinellone의 동시분석법 확립)

  • Song, Ji-Yeon;Lee, Min-A;Yoon, Jeong-Seon;Kim, Dea-Hyun;Kim, Seung-Hyun;Kim, Young-Choong;Sung, Sang-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.323-327
    • /
    • 2010
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of dictamine, obacunone and fraxinellone was established for the quality control of traditional herb Dictamnus dasycarpus cortex. Separation and quantification were successfully achieved with a Shiseido C18 column ($5\;{\mu}m$, 4.6 mm I.D. ${\times}$ 250 mm) by gradient elution of a mixture of methanol and water at a flow rate of 1.0 ml/min. The diode-array UV/Vis detector (DAD) was used for the detection and the wavelength for quantification was set at 236 nm. The presence of dictamine, obacunone and fraxinellone in this extract was ascertained by retention time, spiking with each authentic standard and UV spectrum. All three compounds showed good linearity ($r^2$ > 0.999) in relatively wide concentration ranges. The R.S.D. recovery of each compound was 101.0~103.7% with R.S.D. values less than 1.0%. This method was successfully applied to the determination of contents of dictamine, obacunone and fraxitnellone in three commercial products of D. dasycarpus cortex. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial products.

Simultaneous Determination of Six Bioactive Components in Guibi-tang by HPLC-DAD (HPLC-DAD를 이용한 귀비탕 중 6종 생리활성 물질의 동시분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2010
  • Guibi-tang, a traditional herbal medicine, is used for anti-oxidant, anti-osteoporosis, hemostasis and gastroprotection. To develop an analysis method of simultaneous determination of six compounds, swertisin, decursinol, glycyrrhizin, 6-gingerol, costunolide and decursin in Guibi-tang, a high performance liquid chromatography was used with diode array detector. Six bioactive components were separated on a SHISEIDO $C_{18}$ column ($5\;{\mu}m$, 4.6 mm I.D.${\times}$250 mm) with column temperature $30^{\circ}C$. The gradient elution was composed of water with 0.1% trifluoroacetic acid (TFA) and acetonitrile. UV wavelength was set at 230 nm, 254 nm and 330 nm, respectively. Calibration curve showed good linear regression ($R^2$ > 0.9999). The limits of detection (LOD) and the limits of quantification (LOQ) ranged in 0.03 - 0.23 ${\mu}g/ml$ and 0.08 - $0.70\;{\mu}g/ml$, respectively. The RSD values of intra- and inter-day test were in the range of 0.03 ~ 0.96% and 0.01 ~ 1.46%, respectively. The evaluated results of accuracy test were varied from 92.28% ~ 105.14% with RSD < 1.60%. In conclusion, this developed simultaneous determination method was accuracy and sensitive to the quality evaluation of Guibi-tang.

Simultaneous Determination of Baicalin and Glycyrrhizin in Eul-Ja-Tang by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Park, Jung-Hyun;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-JIn;Kim, Young-Choong;Sung, Sang-Hyun
    • Natural Product Sciences
    • /
    • v.14 no.3
    • /
    • pp.147-151
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, baicalin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Eul-Ja-Tang (EJT). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/VIS detector (DAD) was used for the detection and the wavelength for quantification was set at 250 nm. The presence of baicalin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. Both baicalin and glycyrrhizin showed good linearity ($r^2$ > 0.999) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 5% and the limits of detection (LOD) were about 30 ng. The mean recovery of each compound was 99.5 - 101.2% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of baicalin and glycyrrhizin in three commercial products of EJT, which resulted in the difference in the contents of these compounds. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial EJT products.

Development of an UPLC-DAD Method for Simultaneous Analysis of Eight Marker Compounds of Bulhwangeumjeonggi-san (UPLC-DAD를 이용한 불환금정기산의 다성분 동시분석법 개발)

  • Lee, Kyung-hee;Lamichhane, Ramakanta;Kumar, Sharma Dipak;Raj, Pandeya Prakash;Kim, Se-Gun;Jung, Hyun-Ju
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.4
    • /
    • pp.366-373
    • /
    • 2016
  • Bulhwangeumjeonggisan (BHGJGS) is a traditional herbal formulation generally used in the treatment of cold and gastritis. BHGJGS consists of eight herbal plants; Atractylodis Rhizoma, Magnoliae Cortex, Citri Pericarpium, Glycyrrhizae Radix, Agastachis Herba, Pinelliae Rhizoma, Zingiberis Rhizoma and Zizyphi Fructus. Complete standardization of this formulation has not been done yet. So, a simple and accurate method was developed and validated using Ultra Performance Liquid Chromatography (UPLC) with Diode Array Detector (DAD) for the standardization of BHGJGS. UPLC conditions were optimized using a c18 RP-Amide column with mobile phase; 0.1% phosphate buffer and acetonitrile, detection wavelength; 210 and 325 nm. The linearities of calibration curves were acceptable ($R^2$>0.9994), and the limit of detection and quantification were within the ranges of 0.011-0.091 and $0.034-0.277{\mu}g/ml$ respectively. The relative standard deviation (RSD) of intra- and inter-day precisions were under 3.61%. The RSD of repeatability was under 0.68 %. The results of recovery test were 94.4-107.9%, and the RSD were under 4.6%. The developed method was used to find the contents of standard constituents in BHGJGS mix extract powder, and two commercial formulation (A and B). The data show that the developed method was specific, sensitive, accurate, and precise for analysis of BHGJGS components.

Comparative Analyses of Bioactive Constituents from Forsythia suspensa and Forsythia viridissima by HPLC-DAD

  • Won, Tae-Hyung;Liao, Lijuan;Lee, Seung-Ho;Son, Jong-Keun;Shin, Jong-Heon
    • Natural Product Sciences
    • /
    • v.17 no.4
    • /
    • pp.328-336
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) method was established for the discrimination of a folk medicine Forsythia suspensa and Forsythia viridissima. Five and three representative metabolites of the lignan and phenolic glycoside classes were selected for the analysis from F. suspensa and F. viridissima, respectively. The optimal chromatographic conditions were obtained on an ODS column (5 ${\mu}m$, $4.6{\times}250$ mm) with the column temperature at $40^{\circ}C$. The mobile phase was composed of methanol and 0.3% acetic acid using an isocratic elution with the flow rate 1 mL/min. Detection wavelength was set at 280 nm. All calibration curves showed good linear regression ($r^2$ > 0.996) within test ranges. Limits of detection (LOD) and limits of quantitation (LOQ) values were lower than 0.096 and 0.291 ${\mu}g/mL$, respectively. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.07-0.63% and 0.14-0.62%, respectively, and the overall recoveries of 97.79-102.46% for all of the compounds analyzed. In addition, effectiveness of diverse extraction methods was compared to each other for the development of standard analytical method. The verified method was successfully applied to the quantitative determination of representative metabolites in fifty-three commercial F. suspensa samples and fifteen commercial F. viridissima samples from diverse sources. The overall analytical results showed the unequivocal differences in bioactive constituents between F. suspensa and F. viridissima.

Identification and toxigenic potential of a Nostoc sp.

  • Nowruzi, Bahareh;Khavari-Nejad, Ramezan-Ali;Sivonen, Karina;Kazemi, Bahram;Najafi, Farzaneh;Nejadsattari, Taher
    • ALGAE
    • /
    • v.27 no.4
    • /
    • pp.303-313
    • /
    • 2012
  • Cyanobacteria are well known for their production of a multitude of highly toxic and / or allelopathic compounds. Among the photosynthetic microorganisms, cyanobacteria, belonging to the genus Nostoc are regarded as good candidate for producing biologically active secondary metabolites which are highly toxic to humans and other animals. Since so many reports have been published on the poisoning of different animals from drinking water contaminated with cyanobacteria toxins, it might be assumed that bioactive compounds are found only in aquatic species causes toxicity. However, the discovery of several dead dogs, mice, ducks, and fish around paddy fields, prompted us to study the toxic compounds in a strain of Nostoc which is most abundant in the paddy fields of Iran, using polymerase chain reaction and liquid chromatography coupled with a diode array detector and mass spectrophotometer. Results of molecular analysis demonstrated that the ASN_M strain contains the nosF gene. Also, the result of ion chromatograms and $MS^2$ fragmentation patterns showed that while there were three different peptidic compound classes (anabaenopeptin, cryptophycin, and nostocyclopeptides), there were no signs of the presence of anatoxin-a, homoanatoxin-a, hassallidin or microcystins. Moreover, a remarkable antifungal activity was identified in the methanolic extracts. Based on the results, this study suggests that three diverse groups of potentially bioactive compounds might account for the death of these animals. This case is the first documented incident of toxicity from aquatic cyanobacteria related intoxication in dogs, mice, and aquatic organisms in Iran.

Simultaneous Determination of Paeoniflorin and Glycyrrhizin in Sayuk-san by HPLC/DAD

  • Lee, Mi-Kyeong;Lee, Ki-Yong;Kim, Seung-Hyun;Jeon, Min-Ji;Cho, Jung-Hee;Oh, Mi-Hyun;Baek, Ju-Hyun;Kim, Hyo-Jin;Sung, Sang-Hyun
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.23-27
    • /
    • 2009
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of marker constituents, paeoniflorin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Sayuk-san (SYS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}150mm$) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 mL/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of paeoniflorin and glycyrrhizin in this decoction was ascertained by retention time, spiking with each authentic standard and UV spectrum. All two compounds showed good linearity ($r^2$>0.996) in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.3% and the limits of detection (LOD) were less than 55.7 ng. The mean recovery of each compound was $102.3{\sim}111.1%$ with R.S.D. values less than 4.6%. This method was successfully applied to the determination of contents of paeoniflorin and glycyrrhizin in three commercial products of SYS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial SYS products.

Bioequivalence of Cyclosporine A 100 mg Soft Capsules (Cipol-N® vs. Sandimmun Neoral®) in Healthy Korean Volunteers

  • Huh, Yong-Ho;Park, Eun-A;Chung, Youn-Bok;Pyo, Hee-Soo;Kwon, Oh-Seung
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.5
    • /
    • pp.343-348
    • /
    • 2008
  • The bioequivalence of two cyclosporine A (CyA) 100 mg soft capsules (Chong Kun Dang's $Cipol-N^{(R)}$ as the test drug; Korea Novartis' Sandimmun $Neoral^{(R)}$ as the reference drug) was assessed in healthy male Korean volunteers after oral administration of 200 mg CyA according to a randomized crossover design. The whole blood samples were analyzed for the determination of parent CyA in the blood by using a validated HPLC/diode array detector method. The mean $AUC_t$ values for reference and test products were $4095.3{\pm}1397.2$ and $3958.3{\pm}1138.2\;ng{\cdot}hr/mL$, respectively. The mean $C_{max}$ values were $1135.9{\pm}293.2\;ng/mL$ for the reference product, and $985.0{\pm}207.9\;ng/mL$ for the test product. $T_{max}$ was $1.6{\pm}0.4\;hr$ for the reference and $1.8{\pm}0.5\;hr$ for the test product. The differences of $AUC_t$, $C_{max}$ and $T_{max}$ were -3.35, -13.28 and +10.63%, respectively. The point estimates and 90% confidence intervals for $AUC_t$ and $C_{max}$ were 0.981 (0.9171 to 1.0514) and 0.876 (0.8229 to 0.9336), respectively. Based on the pharmacokinetic and statistical data, we conclude that these two products are bioequivalent and can be considered interchangeable in the medical practice.