Evluation of the DINAMAP 8100 Automated Blood Pressure monitor ; comparison with the Mercury Sphygmomanometer (수은 혈압계와 DINAMAP 8100 자동 혈압계의 혈압측정치 비교연구)

  • Kim Mee-Yeon;Choi Hee-Kang;Kim Nam-Jin
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.3 no.1
    • /
    • pp.96-107
    • /
    • 1996
  • Automated blood pressure monitors have gained acceptance in many clinical settings with the increasing demand, the accurate BP measuring devices reguire the need for validation. We have evaluated the Dinamap 8100, an oscillometric automated blood pressure monitor, using the Mercury sphygmomanometer as a reference. Comparison of sphygmomanometers was conducted 60 patients (30-Normotensive group, 30-Hypertensive group at Seoul National University Hospital. Two trained observers took measure blood pressure(systolic/diastolic) at the same time using the Dinamap 8100 on one arm and the Mercury on the other. For each measurement, the device was randomly selected from a group of devices repetively used for the experiment. Mean readings for systolic pressure with the Dinamap 8100 in normotensive group were lower(mean difference ; 4.26mmHg) than the Mercury type. Mean readings for systolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.05mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in normotensive group were lower (mean difference ; 7.46mmHg) than the Mercury type. Mean readings for diastolic pressure with the Dinamap 8100 in hypertensive group were lower(mean difference ; 9.03mmHg) than the Mercury type. We have found that blood pressure readings with the Dinamap 8100 were lower than those with the Mercury type. we are using the Mercury type in clinics, although it has observer bias and terminal digit preference. But the Dinamap 8100 is readily portable, simple to use, and capable of preventing observer bias and terminal digit preference. The Dinamap 8100 is acceptable for blood pressure determination in subjects who are normotensive or hypertensive ones.

  • PDF

Validation study of the Dinamap ProCare 200 upper arm blood pressure monitor in children and adolescents

  • Lee, Chong-Guk;Park, Hyang-Mi;Shin, Hye-Jung;Moon, Jin-Soo;Hong, Young-Mi;Kim, Nam-Soo;Ha, Il-Soo;Chang, Myeong-Jin;Oh, Kyeong-Won
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.11
    • /
    • pp.463-469
    • /
    • 2011
  • Purpose: To validate the Dinamap ProCare 200 blood pressure (BP) monitor against a mercury sphygmomanometer in children 7 to 18 years old in accordance with the 2010 International Protocol of European Society of Hypertension (ESH-IP2) and the British Hypertension Society (BHS) protocol. Methods: Forty-five children were recruited for the study. A validation procedure was performed following the protocol based on the ESH-IP2 and BHS protocols for children and adolescents. Each subject underwent 7 sequential BP measurements alternatively with a mercury sphygmomanometer and the test device by trained nurses. The results were analyzed according to the validation criteria of ESH-IP2. Results: The mean (${\pm}SD$) difference in the absolute BP values between test device and mercury sphygmomanometer readings was $1.85{\pm}1.65$ mmHg for systolic BP (SBP) and $4.41{\pm}3.53$ mmHg for diastolic BP (DBP). These results fulfilled the Association for the Advancement of Medical Instrumentation criterion of a mean${\pm}$SD below $5{\pm}8$ mmHg for both SBP and DBP. The percentages of test device-observer mercury sphygmomanometer BP differences within 5, 10, and 15 mmHg were 96%, 100%, and 100% for SBP, and 69%, 92%, and 100% for DBP, respectively, in the part 1 analysis; both SBP and DBP passed the part 1 criteria. In the part 2 analysis, SBP passed the criteria but DBP failed. Conclusion: Although the Dinamap ProCare 200 BP monitor failed an adapted ESH-IP2, SBP passed. When comparing BP readings measured by oscillometers and mercury sphygmomanometers, one has to consider the differences between them, particularly in DBP, because DBP can be underestimated.

Normative blood pressure references for Korean children and adolescents (한국 소아 청소년 정상 혈압 참고치)

  • Lee, Chong Guk;Moon, Jin Soo;Choi, Joong-Myung;Nam, Chung Mo;Lee, Soon Young;Oh, Kyungwon;Kim, Young Taek
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.1
    • /
    • pp.33-41
    • /
    • 2008
  • Purpose : It is now understood that blood pressure (BP) measurement in the routine pediatric examination is very important because of the relevance of childhood BP to pediatric health care and the development of adult essential hypertension. There hasn't been a reference table of BP for Korean children and adolescents up to now. This study was to make normative BP references and to provide criteria of hypertension for Korean children and adolescents. Methods : BP measurements were done on 57,433 Koean children and adolescents (male: 29,443, female: 27,990), aged 7 to 20 years, in 2005. Heights and weights were measured simultaneously. Oscillometric devices, Dinamap Procare 200 (GE Inc., Milwaukee, Wi, USA), were used for the measurements. BPs were measured 2 times and mean levels were gathered for the analysis. Outliers of 2,373 subjects with overweight per height, over +3SD, were excluded for the analysis. For the BP centiles adjusted by sex, age and height, fixed modified LMS method which was adopted from the mixed effect model of 2004 Task Force in NHLBI (USA) was used. Results : Normative BP tables for Korean children and adolescents adjusted for height percentiles (5th, 10th, 25th, 50th, 75th, 90th, 95th), gender (male, female) and age(7 to 18 years) were completed. Height centiles of Korean children and adolescents are available from Korean Center for Disease Control and Prevention homepage, http://www.cdc.go.kr/webcdc/. Criteria of hypertension (95th, 99th percentile) and normal range of BP (50th, 90th) adjusted for height percentiles, age and gender were made. Conclusion : This is the first study to make normative BP tables and define hypertension for the Korean children and adolescents. Reliability and accuracy of Dinamap Procare 200 oscillometer for BP measurements remains debatable.

Normal blood pressure values and percentile curves measured by oscillometric method in children under 6 years of age (진동식 자동 혈압계로 측정한 6세 이하 아동의 정상 혈압치와 백분위수 곡선)

  • Sohn, Jin A;Lee, Hee Sook;Lim, Kyoung Aha;Yoon, So Young;Jung, Jo Won;Kim, Nam Su;Noh, Chung Il;Lee, Soon Young;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.51 no.9
    • /
    • pp.998-1006
    • /
    • 2008
  • Purpose : Hypertension is defined as average systolic blood pressure and/or diastolic blood pressure that is ${\geq}95^{th}$ percentile for gender, age, and height on ${\geq}three$ occasions. Knowing that blood pressure values increase in children as they grow older, the purposes of this study were to measure blood pressure by an oscillometric device and to determine normal values and percentile curves for children. Methods : Systolic and diastolic blood pressures were measured twice with an oscillometric device in 3,545 boys and 3,145 girls under six years of age, in Seoul. Using this data, we determined average blood pressure values and percentile curves based on gender and age; we subdivided these values into blood pressures of $50^{th}$, $90^{th}$, $95^{th}$, and $99^{th}$ percentiles, by percentile of height. The regression coefficients and standard deviations of the systolic and diastolic blood pressure values were obtained from linear regression models. Results : Older boys and girls had higher systolic and diastolic blood pressure values. Older boys and girls in the same percentile of height for age had higher systolic and diastolic blood pressure values. Taller boys and girls within the same age group had higher systolic and diastolic blood pressure values. Conclusion : Blood pressure standards based on gender, age, and height were obtained via an oscillometric method. Llimitation of this study is that the study population was not from the whole country, but exclusively from Seoul. Nonetheless, the data from this study will be helpful in diagnosing and managing hypertension in Korean children.

Psychophysiologic Responses to Event Imagery in Traffic Accident Related Patients (교통사고관련 환자에서 사건상상에 대한 정신생리반응)

  • Chung, Sang-Keun;Choi, Myong-Su;Hwang, Ik-Keun
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.1
    • /
    • pp.45-51
    • /
    • 2001
  • Objectives: The experience of traffic accident is a kind of the psychosocial stressors to person. The traffic accident-related patients may show the psychophysiologic hyperarousal. So we examined the differences of psychophysiologic response between patients with and without the memory of experienceing a traffic accident. Methods: Twenty-four traffic accident-related patients were divided into two groups according to ther memory of a traffic accident. In psychological assessment, levels of anxiety and depression were evaluated by State-Trait Anxiety Inventory, Beck's Depression Inventory, and Hamilton Rating Scales For Anxiety and Depression. Heart rate, electrodermal response (EDR), and electromyographic activity (EMG) were measured by biofeedback system, and systolic and diastolic blood pressure by automated vital sign monitor during baseline, task, and rest periods. We utilized script-driven imagery technique as a stressful task. The patients listened to the script describing their own traffic accident experience and were instructed to imagine the event during the task period. Statistically analytic data were obtained from the differences of psychological and psychophysiologic data between two groups. Results: The memory group did not show significantly higher EDR than the none memory group, but showed higher tendency during baseline, imagery, and rest periods. The memory group showed significantly lower EMG than the none memory group during rest period. However, there were no differences in other psychophysiologic reponses between the two groups. Conclusion: Our results showed that the memory group had higher tendency in autonomic arousal level such as electrodermal response than the none memory group. We suggest that physicians need to minimize repetitive imagery of traffic accident (reexperience), and decrease the autonomic hyperarousal in the treatment of traffic accident-related patients.

  • PDF