• Title/Summary/Keyword: Dimming level

Search Result 47, Processing Time 0.025 seconds

Prediction of Contrast and Lighting Energy Saivings in a Small Office Space according to Daylight Conditions (소규모 사무실공간에서 주광조건에 따른 대비효과 및 조명에너지 절약예측)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.4
    • /
    • pp.35-43
    • /
    • 2004
  • Illuminance and luminous levels in a small office space due to daylight were calculated to analyze the impact of daylight on contrast and lighting energy savings. Computer simulations were performed for four blind conditions under a clear sky condition. The blind conditions significantly impacted the illuminance an4 luminance level. Visual performance scores were calculated according to the transfer function that uses absolute contrast between target and background surface. The blind condition that had 45 tilted angle toward ground provided good contrast and performance scores. Using a control algorithm of an automated daylight dimming control system lighting energy sayings were predicted. For all blind conditions minimum lighting energy was consumed.

Multi-coded Variable PPM for High Data Rate Visible Light Communications

  • Moon, Hyun-Dong;Jung, Sung-Yoon
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • In this paper, we propose a new modulation scheme called multi-coded variable pulse position modulation (MC-VPPM) for visible light communication systems. Two groups of signals (Pulse Width Modulation (PWM) and Pulse Position Modulation (PPM) groups) are multi-coded by orthogonal codes for transmitting data simultaneously. Then, each multi-level value of the multi-coded signal is converted to pulse width and position which results in not only an improved data rate, but also a processing gain in reception. In addition, we introduce average duty ratio and cyclic shift concepts in PWM through which dimming control for light illumination can be supported without any degradation in communication performance. Through simulation, we confirm that the proposed MC-VPPM shows a comparable BER curve and much greater achievable data rate than the conventional VPPM scheme using a visible light optical channel environment.

IPS-Mode Dynamic LCD-TV Realization with Low Black Luminance and High Contrast by Adaptive Dynamic Image Control Technology

  • Oh, E.Y.;Baik, S.H.;Sohn, M.H.;Kim, K.D.;Hong, H.J.;Bang, J.Y.;Kwon, K.J.;Kim, M.H.;Jang, H.;Yoon, J.K.;Chung, I.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.799-802
    • /
    • 2004
  • In this paper, the active backlight control technology with data processing algorithm was developed in order to improve image quality for IPS-mode LCD-TV applications. The image blinking problem caused by repeatedly abrupt change of the backlight luminance was solved by algorithms-Fba(Flexible Boundary algorithm) and Cfa(Cumulative Feedback algorithm)-and the optimized number and space of backlight dimming steps based on perception. In the IPS-mode 42" TFT-LCD panel, the dynamic contrast ratio can be more than twice the typical level by means of lower block luminance and higher white luminance. Additionally, Power consumption and LCD temperature was decreased.

  • PDF

Effectiveness of Road Lighting on Driver' Vision (도로조명 방식이 운전자 시지각에 미치는 영향)

  • Jeong, Jun-Hwa;Lee, Suk-Ki;Kim, Won-Sik;Lee, Mi-Ae
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.125-131
    • /
    • 2012
  • PURPOSES : Road lighting facilities increase the visibility of road at night in order to improve traffic driver safety and comfort. Generally speaking, current pole lighting has a tendency to create problems of glare and flicker. The phenomenon of glare gives discomfort due to increase of scattered light, when high luminance is in driver's field of view. The phenomenon of flicker occurs due to the driver passing through discontinuous pockets of pole lighting areas. These phenomenon increase eye strain and decrease driver safety. METHODS : Low height line lighting that distributes light lower than driver's eye level has been developed and evaluated to reduce the problems linked to current pole lighting. A test was undertaken with 4 conditions(turn on the general pole lighting, turn off alternate pole lighting, turn on the line lighting and line lighting with 50% dimming). A driver written survey was conducted in order to gain driver feedback. RESULTS : Pupil size and brow frequency compared with degree in pole lighting are reduced. CONCLUSIONS : Low height line lighting environment makes drivers more comfortable than pole lighting environment and is positive lighting method in the energy saving and landscape aspect.

Using High Brightness LED Light Source Controller for Machine Vision (고휘도 LED를 이용한 머신비전용 조명광원 제어기 개발)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.311-318
    • /
    • 2014
  • This paper is to introduce a lighting source controller using high brightness LED to create a clear and reliable condition for an accurate measurement and testing, which is a core technology in clinical image system and mechanical automation system. This controller is designed to supply a stable power in a constant-current system by installing a high brightness LED driver, and to improve the reproducibility of brightness by using 32-bit ARM processor core, dividing brightness quantity into 256 levels, making the remote control and the external interface possible, and preventing and digitizing the brightness inaccuracy caused by errors of resistance values. This controller enables the lighting range to be wide and possible in a low lighting level compared to analog, adds the RS-485 communication function, and makes it for the users to control the on-off function and the dimming level by receiving date from an external device.

Design of Lighting Control Algorithm for Intelligent LED Lighting System (지능형 LED 점등시스템을 위한 점등제어 알고리즘 설계)

  • Hong, Sung-Il;Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.16 no.3
    • /
    • pp.274-282
    • /
    • 2012
  • In this paper, we propose the design of lighting control algorithm for intelligent LED lighting system. The proposed lighting control algorithm transmitted to MCU through a data bus the environmental information detected from respectively sensor node. The MCU control software was designed to determine the level maintained to depending on the set control method by comparing the results that calculated the dimming level using a signal value. Also, it was designed to be lighting by cross-performed periodically the rotation and reverse method by created fully symmetrical pattern using the control algorithm to LED lighting device. In this paper, the proposed lighting control algorithm improved the reliability of the data sent by designed the system that can be controlled lighting to stable, and it was maintained the event delivery ratio of 91%. Also, the lighting device was decreased the luminous intensity of 32%, the power consumption of 49%, and heat generation of 32%. As a result, it were could be improved the energy efficiency that the life-cycle of LED has been increased 50%.

Delta Sigma Modulation of Controller Input Signal for the LED Light Driver (시그마 델타 변조에 의한 LED 드라이버의 입력 콘트롤러 설계)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.151-155
    • /
    • 2016
  • In this paper, we present the LED dimming control system by using ADPCM (Adaptive Differential Pulse Code Modulation). This ADPCM apparatus accurately controls the LED current with high resolution reducing the RFI (radio frequency interference) due to the spreading out of the harmonics of current of pulses. Additionally, this makes it easier to increase the accuracy of control operation. This study introduces to make a digitally controlled circuit for controlling LED with high-energy efficient by adopting pulse current to LED. The LED current drive system we designed are two systems, the digitally-controlled unit and analog switching mode power supply unit, can be developed separately. The simulation shows the sigma delta modulation of digital to analog converter's output when the input level is 0.7. From this simulation, the output is approached to accurately 0.15% to target value with 510 pulses.