• Title/Summary/Keyword: Dimmer

Search Result 66, Processing Time 0.024 seconds

Development of the Digital Dimmer System (디지털 디머 시스템 개발 연구)

  • Jung, Seung-Hwan;Choy, Ick;Choi, Ju-Yeop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.108-115
    • /
    • 2008
  • Recently, a demand of the digital dimmer system is increasing steadily, but domestic research is not sufficient to the expectation. In this paper, a digital dimmer equipment is developed and resented to compose a system. Digital dimmer system compose console and dimmer rack. Console controls of user interface and a total system, and dimmer rack controls brightness of lighting equipment by a way of phase angle control with each illumination level to get from console.

A Study on the Efficiency when replacing SSR Dimmer with IGBT SINEWAVE Dimmer in Concert Halls (공연장에서 사용하고 있는 SSR조광기를 새로운 IGBT 싸인웨이브 조광기로 교체시 효율성에 관한 연구)

  • Lee, Jang-Weon;Kwon, Hyeok-Hwan
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.219-224
    • /
    • 2015
  • Today, High Social demand for Energy Saving. This have been Studied for the purpose, Having an Efficiency of much it, in IGBT DIMMER SYSTEM compared to the existing SSR,SCR Dimmer System. The Method Two, The First is Dimming in Dimmer System How much Power loss Appears of A Comparison Experiment According to the output a SINEWAVE Strain, Comparative Measurements Experimental were Conducted with Oscilloscope. Second, When Dimming the sound has equipment by measuring the relative Size Decibel Experiment was conducted in Decibel Meter about the Equipment Noise. Results Thus Confirm SSR, SCR Dimmer IGBT SINEWAVE Dimmer more Efficiently.

Simulation of IGBT Dimmer Using EMTDC (EMTDC를 이용한 IGBT Dimmer 시뮬레이션)

  • Kim, Bo-Kyong;Park, Min-Won;Seong, Ki-Chul;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.194-196
    • /
    • 2001
  • Light dimming is based on adjusting the voltage which gets to the lamp. Light dimming has been possible for many decades by using adjustable power resistors and adjustable transformers. The power electronics have proceeded quietly since 1960. Between 1960-1970 thyristors and triacs came to market. Using those components it was quite easy to make small and inexpensive light dimmers which have goof efficiency. This type of electronic light dimmers became available after 1970 and are nowadays used in very many locations like homes, restaurants, conference rooms and in stage lighting. But the problem of thyristor dimmer have been that it has poor efficiency and voltage drop. Recently IGBT(Insulated Gate Bipolar Transistor) control is a new way to do light dimming for improving this problems. IGBT dimmer has many other advantages over traditional thyristor dimmer there are no huge current spikes and EMI caused by turn on Using IGBT it is possible to make the turn-off rate relatively slot to achieve quite operations in terms of EMI and acoustical or incandescent lamp filament noise. For the development of IGBT dimmer. This paper shows the effects of IGBT dimmer compared with thyristor dimmer through a simulation using EMTDC.

  • PDF

A Study on LED Driver Compatible with Triac-dimmer Employing Active Bleeder (능동 블리더 회로를 적용한 조광기 호환용 LED 구동회로에 관한 연구)

  • Yeom, Bong-Ho;Hong, Sung-Soo;Kim, Taek-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.4
    • /
    • pp.297-302
    • /
    • 2014
  • In this paper, a LED driver compatible with TRIAC-dimmer applying active bleeder is proposed. If TRIAC-dimmer is connected with LED driver, flicker phenomenon occurs by TRIAC malfunction. In order to prevent this problem, a current over holding current must flow into TRIAC. Therefore, additional circuit compatible with TRIAC-dimmer is required to provide enough current. Passive bleeder has power loss in whole operation period. The proposed circuit apply a valley-fill circuit for power-factor-correction and a novel active bleeder detecting malfunction point of TRIAC. Therefore, it prevent malfunction of TRIAC-dimmer and have advantage of higher efficiency than passive bleeder. To verify the validity of proposed circuit, 13W-lighting LED driver prototype has been proposed.

A Study on harmonics generation and reduction in Dimmer circuits (Dimmer 회로에서의 고조파 발생과 저감에 관한 연구)

  • Park, Seok-Hoon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.252-254
    • /
    • 2000
  • For many years, electric utility has used sustained interruption rates as a reliability index. Today, however, many electricity consumers are adversely affected by more subtle voltage disturbances such as harmonic distortion. This paper deals with observations of events that occur in the Dimmer circuits and phase control which could affect harmonics problem to the commercial power system. In order to reduce the effect of harmonics and design filters, Solid State Relay Dimmer(SCRs or TRIACs) and Noise Filter are described, and the effects of harmonics is also analyzed. IGBT Dimmer which is appropriate method to reduce harmonics and improve efficiency is introduced.

  • PDF

Study on Novel Dimming Method using IGBT (IGBT를 이용한 새로운 Dimming 기법에 관한 연구)

  • Kim, Bo-Kyong;Lim, Chae-Hyung;Park, Min-Won;Seong, Ki-Chul;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1126-1128
    • /
    • 2002
  • In proportion to the development of various cultural contents industry, although the lighting tools with advanced control system are needed, the fields of the lighting tools are not competitive in techniques because they are limited in small businesses and have been lost their markets to foreign companies in the high value added industry. Accordingly, the technique that is better than current lighting tools is needed urgently. So, for the new lighting tools, this paper presents a new dimming method using IGBT(Insulated Gate Bipolar Transistor) devices. There are three procedures in this study. For the first, the authors verify superiority of IGBT Dimmer with simulation using EMTDC in former step for development of IGBT dimmer. Secondly, the authors made IGBT dimmer directly with the basis of simulation results. For the last, the efficiency, the Total Harmonic Distortion(THD) current, temperature characteristic, noise characteristic, voltage drop, heat losses between the IGBT dimmer and the Thyristor dimmer that is being used popularly in the industries the stages, and the theaters were tested and compared..

  • PDF

Digital Dimmer for AC LED (AC LED 용 Digital Dimmer)

  • Kim, Sang-Il;Park, In-Gi;Ha, Seok-Jin;Kim, Jong-Hyun;Yoo, Dong-Wook;Kim, In-Dong
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.280-282
    • /
    • 2009
  • 본 논문은 AC LED에 적합한 Digital Dimmer에 관한 연구이다. PWM 방식을 이용하여 조광 범위를 0~100% 되게 하였을 뿐만 아니라 AC LED를 상용 전원에 연결하여 사용 시 발생하는 플리커 문제를 플리커 개선 알고리즘을 추가하여 해결하였다.

  • PDF

The LED Lighting Control Method Base on DALI Protocol by the Phase Angle Control (위상각 제어에 의한 DALI 프로토콜 기반의 LED조명 제어방법)

  • Choi, Young-Min;Park, Jun-Seok;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.73-80
    • /
    • 2012
  • Generally, the phase control dimmer has been widely used due to simple interface and easy handling. However, the electrical characteristics are not good for the method in which the phase control dimmer cuts the input voltage. This paper has researched about DALI(Digital Addressable Lighting Interface) controller, that is the digital lighting control method, and implemented DALI protocol satisfied with the IEC-62386 standard. In addition, the existing phase control dimmer was used as the controller of DALI and not only individual control but also group control was possible. And the performance was proved to be good by applying our theory to 30[W] LED lighting control system.

A Basic Study on Performance Evaluation of Permanent Supplementary Artificial Lighting of Interior(PSALI) using a LED Light Source (LED광원을 이용한 실내상시보조인공조명(PSALI)의 성능평가에 관한 기초적 연구)

  • Lee, Jin-Sook;Kim, Byoung-Soo;Kim, So-Yeon;Jung, Young-Gyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.16-23
    • /
    • 2011
  • Since the first lighting light source was invented, lighting has turned into superior-quality lighting considering the amenity of occupants, and the characteristics of a light source has developed rapidly. So this research confirmed the lighting performance of a dimmer control system and an ON-OFF control system via the existing light source, and analyzed the basic lighting environment of Permanent Supplementary Artificial Lighting of Interiors(PSALI) through the physical comparison and evaluation of a LED lamp substituted for a fluorescent lamp used in a dimmer control system, showing that the lighting physical quantity characteristics of an ON-OFF control system and a dimmer control system are similar to each other and that they are effective in terms of energy saving. Besides, it was shown that introducing a LED light source to a dimmer control system improves lighting environments and largely reduces energy consumption.

Design of the 140W level-small sized LED Power Control Circuit (140W 급-저면적 LED 전원 제어 회로 설계)

  • An, Ho-Myoung;Lee, Juseong;Kim, Byungcheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.586-592
    • /
    • 2018
  • In this paper, HIC with various functions is proposed for the design 140W LED power control circuit. The proposed HIC integrates constant voltage/constant current circuit, short circuit protection circuit, internal constant voltage circuit, and dimmer circuit, thereby reducing the horizontal length of the PCB by 16% comparing with the conventional system. Through various experiments, we verified the performance of each block implemented inside of HIC with numerical results. (Constant voltage variation ratio: 2.9%, dimmer circuit duty variation within 5%, stable short protection at 720 mA) Since the PCB area can be significantly reduced by applying the proposed HIC. It is possible to reduce the PCB manufacturing time which takes up most of the manufacturing time, however, It is expected that the faulted power module can be replaced without replacing the whole PCB, so that maintenance / repair can be made easier.