• Title/Summary/Keyword: Dimensional measurement accuracy

Search Result 352, Processing Time 0.025 seconds

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

Intraobserver and interobserver reproducibility in linear measurements on axial images obtained by cone-beam computed tomography

  • Silva, Nathalia Cristine da;Barriviera, Mauricio;Junqueira, Jose Luiz Cintra;Panzarella, Francine Kuhl;Raitz, Ricardo
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.11-15
    • /
    • 2017
  • Purpose: This study was performed to investigate the intra- and inter-observer variability in linear measurements with axial images obtained by PreXion (PreXion Inc., San Mateo, USA) and i-CAT(Imaging Sciences International, Xoran Technologies Inc., Hatfield, USA) CBCT scanners, with different voxel sizes. Materials and Methods: A cylindrical object made from nylon with radiopaque markers (phantom) was scanned by i-CAT and PreXion 3D devices. For each axial image, measurements were taken twice in the horizontal(distance A-B) and vertical (distance C-D) directions, randomly, with a one-week interval between measurements, by four oral radiologists with five years or more experience in the use of these measuring tools. Results: All of the obtained linear measurements had lower values than those of the phantom. The statistical analysis showed high intra- and inter-observer reliability (p=0.297). Compared to the real measurements, the measurements obtained using the i-CAT device and PreXion tomography, on average, revealed absolute errors ranging from 0.22 to 0.59 mm and from 0.23 to 0.63 mm, respectively. Conclusion: It can be concluded that both scanners are accurate, although the linear measurements are underestimations, with no significant differences between the evaluators.

Assessment of over / under-break of tunnel utilizing BIM and 3D laser scanner (3차원 레이저 스캐너 및 BIM을 활용한 터널 과대.과소 굴착 평가)

  • Park, Jeong-Jun;Shin, Jae-Chou;Hwang, Ju-Hwan;Lee, Kang-Hyun;Seo, Hyung-Joon;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.4
    • /
    • pp.437-451
    • /
    • 2012
  • Application of 3D laser scanner to civil engineering is widely studied in various fields such as tunnel, bridge, calculation of earth volume, construction measurement, observation of rock joint, etc. Some studies on utilization of the 3D laser scanner for calculating the over-break and/or under-break of tunnels have also been carried out. However, in the previous research, the scanning data were usually compared with the 2D CAD blueprint results; although the shape of tunnel structure is relatively simple, for precise calculation of the over-break and/or under-break of tunnels, three-dimensional analysis based on BIM is needed. Therefore, in this paper, a new program that calculates the over-break and/or under-break of tunnels using the 3D laser scanner and the BIM is developed; moreover the effective and rapid process of data treatment is proposed. The accuracy of the developed program was verified by applying the new system to a real tunnels construction field.

Usefulness of four commonly used neuropathic pain screening questionnaires in patients with chronic low back pain: a cross-sectional study

  • Gudala, Kapil;Ghai, Babita;Bansal, Dipika
    • The Korean Journal of Pain
    • /
    • v.30 no.1
    • /
    • pp.51-58
    • /
    • 2017
  • Background: Recently symptoms-based screening questionnaires have gained attention for screening for a neuropathic pain component (NePC) in various chronic pain conditions. The present study assessed the usefulness of four commonly used NePC screening questionnaires including the Self-completed douleur neuropathique 4 (S-DN4), the ID Pain, the painDETECT questionnaire (PDQ), and the Self-completed Leeds Assessment of neuropathic Symptoms and Signs (S-LANSS) questionnaire in patients with chronic low back pain (CLBP) to assess the presence of NePC. Methods: This is a single-center cross-sectional study where patients with CLBP, with or without leg pain, were included. Participants were initially screened for NePC presence by a physician according to the regular practice, and later assessed using screening questionnaires. The diagnostic accuracy of these questionnaires was compared assuming the physician-made diagnosis as the gold standard. Results: A total of 215 patients with CLBP of which 164 (76.3%, 95% CI, 70.2-81.5) had a NePC were included. S-DN4, ID Pain, and PDQ have an area under the curve (AUC) > 0.8 indicating excellent discrimination. However, S-LANSS has an AUC of 0.69 (0.62-0.75), indicating low discrimination. S-DN4 has a significantly higher AUC as compared to ID Pain (d(AUC) = 0.063, P < 0.01) and S-LANSS (d(AUC) = 0.197, P < 0.01). But the AUC of S-DN4 does not significantly differ from that of PDQ (d(AUC) = 0.013, P = 0.62). Conclusions: S-DN4, ID Pain, and PDQ, but not S-LANSS, have good discriminant validity to screen for NePCs in patients with CLBP. Despite using all the tests, 20-30% of patients with an NePC were missed. Thus, these questionnaires can only be used as an initial clue in screening for NePCs, but do not replace clinical judgment.

Comparison of the 3D Digital Photogrammetry and Direct Anthropometry in Unilateral Cleft Lip Patients (일측성 구순열 환자에서 3차원 수치사진측량 스캔과 직접계측 방법의 비교)

  • Seok, Hyo Hyun;Kwon, Geun-Yong;Baek, Seung-Hak;Choi, Tae Hyun;Kim, Sukwha
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.11-15
    • /
    • 2013
  • Background: In cleft lip patients, the necessity of a thorough preoperative analysis of facial deformities before reconstruction is unquestioned. The surgical plan of cleft lip patient is based on the information gained from our preoperative anthropometric evaluation. A variety of commercially available three-dimensional (3D) surface imaging systems are currently introduced to us in plastic surgery for these use. However, few studies have been published on the soft tissue morphology of unrepaired cleft infants described by these 3D surface imaging systems. Methods: The purpose of this study is to determine the accuracy of facial anthropometric measurements obtained through digital 3D photogrammetry and to compare with direct anthropometry for measurement in unilateral cleft lip patients. We compared our patients with three measurements of dimension made on both sides: heminasal width, labial height, and transverse lip length. Results: The preoperative measurements were not significantly different in both side of labial height and left side of heminasal width. Statistically significant differences were found on both side of transverse lip length and right side of heminasal width. Although the half of preoperative measurements were significantly different, trends of results showed average results were comparable. Conclusion: This is the first study in Korea to simultaneously compare digital 3D photogrammetry with traditional direct anthropometry in unilateral cleft lip patients. We desire this study could contribute the methodological choice of the many researchers for proper surgical planning in cleft lip reconstruction field.

The Stereo Camera Measurement of Point Cloud on 3D Object and the Calculation of Volume Based on Irregular Triangular Mesh (스테레오 카메라와 측정에 의한 3D 대상체 포인트 클라우드의 불규칙 삼각 매싱 기반 체적 계산)

  • Lee, Young-Dae;Cho, Sung-Youn;Kim, Kyung;Lee, Dong-Gyu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.4
    • /
    • pp.153-159
    • /
    • 2012
  • For the construction of safe and clear urban environment, it is necessary that we identify the rubbish waste volume and we know the accuracy volume. In this paper, we proposed the algorithm computes the waste volume periodically for the way of waste repository standard. After stereo camera calibration, we obtained the point cloud on the surface of the object and took this as the input of the calculation algorithm of the object volume. We proposed the volume calculation algorithms based on the non-uniform triangular meshing methods and verified the validity of the algorithm through simulation and real experiments. The proposed algorithm can be used not only as the volume calculation of the waste repository but also as the general volume calculation of a three dimensional object.

Validity of a Portable APDM Inertial Sensor System for Stride Time and Stride Length during Treadmill Walking

  • Tack, Gye Rae;Choi, Jin Seung
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.1
    • /
    • pp.53-58
    • /
    • 2017
  • Objective: The purpose of this study was to compare the accuracy of stride time and stride length provided by a commercial APDM inertial sensor system (APDM) with the results of three dimensional motion capture system (3D motion) during treadmill walking. Method: Five healthy men participated in this experiment. All subjects walked on the treadmill for 3 minutes at their preferred walking speed. The 3D motion and the APDM were simultaneously used for extracting gait variables such as stride time and stride length. Mean difference and root mean squared (RMS) difference were used to compare the measured gait variables from the two measurement devices. The regression equation derived from the range of motion of the lower limb was also applied to correct the error of stride length. Results: The stride time extracted from the APDM was almost the same as that from the 3D motion (the mean difference and RMS difference were less than 0.0001 sec and 0.0085 sec, respectively). For stride length, mean difference and RMS difference were less than 0.1141 m and 0.1254 m, respectively. However, after correction of the stride length error using the derived regression equation, the mean difference and the RMS difference decreased to 0.0134 m and 0.0556 m or less, respectively. Conclusion: In this study, we confirmed the possibility of using the temporal variables provided from the APDM during treadmill walking. By applying the regression equation derived only from the range of motion provided by the APDM, the error of the spatial variable could be reduced. Although further studies are needed with additional subjects and various walking speeds, these results may provide the basic data necessary for using APDM in treadmill walking.

Performance Comparison of Various Extended Kalman Filter and Cost-Reference Particle Filter for Target Tracking with Unknown Noise (노이즈 불확실성하에서의 확장칼만필터의 변종들과 코스트 레퍼런스 파티클필터를 이용한 표적추적 성능비교)

  • Shin, Myoungin;Hong, Wooyoung
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.3
    • /
    • pp.99-107
    • /
    • 2018
  • In this paper, we study target tracking in two dimensional space using a Extended Kalman filter(EKF), various Extended Kalman Filter and Cost-Reference Particle Filter(CRPF), which can effectively estimate the state values of nonlinear measurement equation. We introduce various Extended Kalman Filter which the Unscented Kalman Filter(UKF), the Central Difference Kalman Filter(CDKF), the Square Root Unscented Kalman Filter(SR-UKF), and the Central Difference Kalman Filter(SR-CDKF). In this study, we calculate Mean Square Error(MSE) of each filters using Monte-Carlo simulation with unknown noise statistics. Simulation results show that among the various of Extended Kalman filter, Square Root Central Difference Kalman Filter has the best results in terms of speed and performance. And, the Cost-Reference Particle Filter has an advantageous feature that it does not need to know the noise distribution differently from Extended Kalman Filter, and the simulation result shows that the excellent in term of processing speed and accuracy.

Free Surface Flow in a Trench Channel Using 3-D Finite Volume Method

  • Lee, Kil-Seong;Park, Ki-Doo;Oh, Jin-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.6
    • /
    • pp.429-438
    • /
    • 2011
  • In order to simulate a free surface flow in a trench channel, a three-dimensional incompressible unsteady Reynolds-averaged Navier-Stokes (RANS) equations are closed with the ${\kappa}-{\epsilon}$ model. The artificial compressibility (AC) method is used. Because the pressure fields can be coupled directly with the velocity fields, the incompressible Navier-Stokes (INS) equations can be solved for the unknown variables such as velocity components and pressure. The governing equations are discretized in a conservation form using a second order accurate finite volume method on non-staggered grids. In order to prevent the oscillatory behavior of computed solutions known as odd-even decoupling, an artificial dissipation using the flux-difference splitting upwind scheme is applied. To enhance the efficiency and robustness of the numerical algorithm, the implicit method of the Beam and Warming method is employed. The treatment of the free surface, so-called interface-tracking method, is proposed using the free surface evolution equation and the kinematic free surface boundary conditions at the free surface instead of the dynamic free surface boundary condition. AC method in this paper can be applied only to the hydrodynamic pressure using the decomposition into hydrostatic pressure and hydrodynamic pressure components. In this study, the boundary-fitted grids are used and advanced each time the free surface moved. The accuracy of our RANS solver is compared with the laboratory experimental and numerical data for a fully turbulent shallow-water trench flow. The algorithm yields practically identical velocity profiles that are in good overall agreement with the laboratory experimental measurement for the turbulent flow.

Optical System Design and Experimental Demonstration of Long-range Reflective-type Precision Displacement Sensors (반사형 장거리 정밀 변위 감지기용 광학계 설계 및 측정)

  • Lim, Jae-In;Kim, Seung-Hwan;Lee, Seoung-Hun;Jeong, Hae-Won;Lee, Min-Hee;Kim, Shung-Whan;Kim, Kyong-Hon
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.3
    • /
    • pp.151-158
    • /
    • 2011
  • This paper reports design and demonstration of optical systems for reflective-type remote optical displacement sensors. Optical systems for light illumination sources and a position sensitive detector (PSD) for the displacement sensor were developed to sense displacement of bridges and instability of skyscrapers in a distance range from 10 m to 250 m to an accuracy better than a few mm. Performance of the optical systems was verified by composing a displacement sensor and by using it in measurement of displacement of a remote target with proper reflective optics depending on distance. The displacement sensor was composed of two LED light sources, each with collimating optics, and a two-dimensional PSD with telescope-type optics. Its displacement resolutions was measured to be 0.1 mm at a distance of 10 m and less than 3 mm at a distance of 250 m.