• 제목/요약/키워드: Dimensional measurement accuracy

검색결과 352건 처리시간 0.034초

Design of 3D Laser Radar Based on Laser Triangulation

  • Yang, Yang;Zhang, Yuchen;Wang, Yuehai;Liu, Danian
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권5호
    • /
    • pp.2414-2433
    • /
    • 2019
  • The aim of this paper is to design a 3D laser radar prototype based on laser triangulation. The mathematical model of distance sensitivity is deduced; a pixel-distance conversion formula is discussed and used to complete 3D scanning. The center position extraction algorithm of the spot is proposed, and the error of the linear laser, camera distortion and installation are corrected by using the proposed weighted average algorithm. Finally, the three-dimensional analytic computational algorithm is given to transform the measured distance into point cloud data. The experimental results show that this 3D laser radar can accomplish the 3D object scanning and the environment 3D reconstruction task. In addition, the experiment result proves that the product of the camera focal length and the baseline length is the key factor to influence measurement accuracy.

광학현미경을 이용한 비접촉식 치수측정시스템의 교정 (Calibration of Optical Dimensional Measurement System Using Optical Microscope)

  • 박현구;박민철;김승우
    • 한국정밀공학회지
    • /
    • 제14권11호
    • /
    • pp.118-125
    • /
    • 1997
  • Non-contacting optical microscopes are increasingly used in recent industrial applications of probes for coordinate measuring machines. They have been found more efficient than conventional touch trigger porbes with ball tips especially in inspecting small-sized objects. There are two major factors affecting measuring accuracy: (1) geometric relations between coordinate systems, (2) magnification ratios of a microscope. In order to determine the magnification ratios exactly, optical imaging of edge was theroretically analyzed and practically adopted to image processing for edge detection. In addition, this paper proposes a geometric calibration method to obtain exact coordinates of measured points from the relations between the machine coordinate system and the image. In the method, the error according to the squareness between the machine axises was also removed. The method was practically adopted to a real coordinate measuring machine. An ultraprecision measurement of 0.2 um uncertainty can be practically achieved.

  • PDF

A Density Peak Clustering Algorithm Based on Information Bottleneck

  • Yongli Liu;Congcong Zhao;Hao Chao
    • Journal of Information Processing Systems
    • /
    • 제19권6호
    • /
    • pp.778-790
    • /
    • 2023
  • Although density peak clustering can often easily yield excellent results, there is still room for improvement when dealing with complex, high-dimensional datasets. One of the main limitations of this algorithm is its reliance on geometric distance as the sole similarity measurement. To address this limitation, we draw inspiration from the information bottleneck theory, and propose a novel density peak clustering algorithm that incorporates this theory as a similarity measure. Specifically, our algorithm utilizes the joint probability distribution between data objects and feature information, and employs the loss of mutual information as the measurement standard. This approach not only eliminates the potential for subjective error in selecting similarity method, but also enhances performance on datasets with multiple centers and high dimensionality. To evaluate the effectiveness of our algorithm, we conducted experiments using ten carefully selected datasets and compared the results with three other algorithms. The experimental results demonstrate that our information bottleneck-based density peaks clustering (IBDPC) algorithm consistently achieves high levels of accuracy, highlighting its potential as a valuable tool for data clustering tasks.

악교정 수술을 위한 석고모형 수술시의 계측오차 (THE ACCURACY OF MEASUREMENTS DURING MODEL SURGERY FOR ORTHOGNATHIC PLANNING)

  • 이상휘;이승훈;주현호;원동환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권1호
    • /
    • pp.37-45
    • /
    • 2001
  • The errors in orthognathic surgery can occur during the preoperative preparations including the model surgery, but till now there's been some lack of reserches about them. So we wanted to verify the accuracies in measurements used in model surgery. We compared the accuracy of measurements by vernier calipers, which has been the main measurement tool for conventional model surgery, and that by height gauge, which is recently claimed to be more accurate, with 3 dimensional coordinate analyzer. We could have following results and have a plan to use them for the invention of new model surgery techniques. 1. The measurement errors in Group 1, which mean the difference between "the measurements by 3-D analyzer"and "the measurements by height gauge", were small enough with the range of $0.1{\sim}0.2mm$ in all planes. 2. The mean error in Group 2, which is the differences between the measurements of 3-D analyzer and those of vernier calipers, was 1.1mm. 3. The measurement errors in Group 2 were variable according to the factors including the differences of individuality and expertness of each measurers. But in case of Group 1, they were small and not variable by the expertness. 4. The measurements were more accurate at the points in anterior teeth than in molar teeth in Group 1 and 2. 5. The errors after model surgery increased remarkably, compared with those before surgery in Group 2. And the situation was different in Group 1 in that errors decreased after surgery. According to these results, it assumed that the measurements with height gauge during the model surgery for orthognathic surgery are accurate enough and can be maintained, regardless of complexity of models, individuality, or expertness of measurers.

  • PDF

Photogrammetry 기법을 활용한 MSC 설치면의 정밀 측정

  • 우성현;김홍배;문상무;임종민
    • 항공우주기술
    • /
    • 제3권1호
    • /
    • pp.126-133
    • /
    • 2004
  • 사진측량법(Photogrammetry)는 서로 다른 촬영각을 가지는 다수의 2차원 이미지로부터 대상물의 정밀한 3차원 형상을 얻어내는 기법이다. 본 연구에서는 사진측량법을 활용하여 다목적 실용위성 2호 비행모델 하부 탑재체 플랫폼(Low Payload Platform)의 고해상도 카메라 접합면에 대한 편평도(Flatness) 측정 작업을 수행하였으며, 정밀하게 교정된 2개의 스케일바(Scale Bar)를 사용하여 절대적인 길이 값을 3차원 모델에 부과함과 동시에 측정정확도를 계산하여 내었다. 또한 측정된 편평도 결과는 고해상도 카메라 납품 업체에서 제시한 편평도 요구조건과 비교되었다.

  • PDF

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

수작업의 반복성 평가 방법 조사 (A Survey of Repetitiveness Assessment Methodologies for Hand-Intensive Tasks)

  • 권오채;유희천
    • 대한인간공학회지
    • /
    • 제22권3호
    • /
    • pp.75-91
    • /
    • 2003
  • Evaluation of repetitiveness for hand-intensive tasks is essential to determine the level of risk for upper-extremity musculoskeletal disorders at the workplace. Many measures and methods have been introduced for repetitiveness assessment: however, our understanding of the differences among these measures and methods is lacking. The present study compared the repetitiveness measures and measurement/analysis methods to help practitioners apply the proper repetitiveness assessment methodology in the workplace. By reviewing 51 studies of repetitiveness assessment, measures and corresponding measurement/analysis methods were surveyed. Of the repetitiveness measures, two types of dimensions (frequency and time) and corresponding types of analysis scopes were identified. According to the dimensional and analysis-scope types. the repetitiveness measures were categorized and then the surveyed studies were counted for each measure. It is identified that frequency measures have used 2.7 times higher than time measures and the frequency of wrist motions has been most frequently used in repetitiveness assessment. Furthermore, the measurement methods were categorized into objective and subjective methods, and the analysis methods into statistical and spectral methods. Lastly, eight factors (accuracy, reliability. sensitivity. efficiency. ease of use. applicability. interference. and robustness) were listed to be considered in selecting the appropriate assessment methodology.

막구조물의 막장력 측정장치 개발에 관한 연구 (DEVEOPMENT OF MEASURING SYSTEM OF MEMBRANE STRESS FOR MEMBRANE STRUCTURE)

  • 정한목;우재원;조병욱;이성연
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2008년도 춘계 학술발표회 논문집
    • /
    • pp.171-178
    • /
    • 2008
  • This paper is concerned with the development of a measurement system using field measuring device which will give the membrane stress of the membrane structures. Up to this point, several techniques on measurement of membrane stresses has been proposed and some have been used in the fields, but accuracy of the measured stresses to be far from reliable one. Such situation has not been changed until recent days, we do not have the measurement device on which we can depend. On top of that, due to the different properties in cross directions for material of the membrane, the stress in the warp direction is different from that in the fill one. A new method is proposed to measured membrane stresses in two different direction separately, where instead of membrane stresses directly, an external force perpendicular to the membrane to be applied. A portable device can measure the applied force and the displacement. A special testing bed to be fabricated to accommodate $50cm{\times}50$ manbrane specimen which can apply 5 ton load in two orthogonal direction. A special device using push-pull gage was developed. To measure the membrane stresses in warp and fill direction separately, a different length of the tips are used. The measuring device which can called tension meter, can be calibrated on the testing bed, and optimized the length and shape of tip.

  • PDF

스테레오 카메라와 2축 회전기구를 이용한 대형 이동물체의 치수측정 (Dimension Measurement for Large-scale Moving Objects Using Stereo Camera with 2-DOF Mechanism)

  • 응후쿠옹;이병룡
    • 한국정밀공학회지
    • /
    • 제32권6호
    • /
    • pp.543-551
    • /
    • 2015
  • In this study, a novel method for dimension measurement of large-scale moving objects using stereo camera with 2-degree of freedom (2-DOF) mechanism is presented. The proposed method utilizes both the advantages of stereo vision technique and the enlarged visibility range of camera due to 2-DOF rotary mechanism in measuring large-scale moving objects. The measurement system employs a stereo camera combined with a 2-DOF rotary mechanism that allows capturing separate corners of the measured object. The measuring algorithm consists of two main stages. First, three-dimensional (3-D) positions of the corners of the measured object are determined based on stereo vision algorithms. Then, using the rotary angles of the 2-DOF mechanism the dimensions of the measured object are calculated via coordinate transformation. The proposed system can measure the dimensions of moving objects with relatively slow and steady speed. We showed that the proposed system guarantees high measuring accuracy with some experiments.

MSBS-SPR Integrated System Allowing Wider Controllable Range for Effective Wind Tunnel Test

  • Sung, Yeol-Hun;Lee, Dong-Kyu;Han, Jong-Seob;Kim, Ho-Young;Han, Jae-Hung
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.414-424
    • /
    • 2017
  • This paper introduces an experimental device which can measure accurate aerodynamic forces without support interference in wide experimental region for wind tunnel test of micro aerial vehicles (MAVs). A stereo pattern recognition (SPR) method was introduced to a magnetic suspension and balance system (MSBS), which can eliminate support interference by levitating the experimental model, to establish wider experimental region; thereby MSBS-SPR integrated system was developed. The SPR method is non-contact, highly accurate three-dimensional position measurement method providing wide measurement range. To evaluate the system performance, a series of performance evaluations including SPR system measurement accuracy and 6 degrees of freedom (DOFs) position/attitude control of the MAV model were conducted. This newly developed system could control the MAV model rapidly and accurately within almost 60mm for translational DOFs and 40deg for rotational DOFs inside of $300{\times}300mm$ test section. In addition, a static wind tunnel test was conducted to verify the aerodynamic force measurement capability. It turned out that this system could accurately measure the aerodynamic forces in low Reynolds number, even for the weak forces which were hard to measure using typical balance system, without making any mechanical contact with the MAV model.