• Title/Summary/Keyword: Dimensional measurement accuracy

Search Result 351, Processing Time 0.03 seconds

Two-dimensional Velocity Measurements of Uvêrsbreen Glacier in Svalbard Using TerraSAR-X Offset Tracking Approach (TerraSAR-X 위성레이더 오프셋 트래킹 기법을 활용한 스발바르 Uvêrsbreen 빙하의 2차원 속도)

  • Baek, Won-Kyung;Jung, Hyung-Sup;Chae, Sung-Ho;Lee, Won-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.495-506
    • /
    • 2018
  • Global interest in climate change and sea level rise has led to active research on the velocities of glaciers. In studies about the velocity of glaciers, in-situ measurements can obtain the most accurate data but have limitations to acquire periodical or long-term data. Offset tracking using SAR is actively being used as an alternative of in-situ measurements. Offset tracking has a limitation in that the accuracy of observation is lower than that of other observational techniques, but it has been improved by recent studies. Recent studies in the $Uv{\hat{e}}rsbreen$ glacier area have shown that glacier altitudes decrease at a rate of 1.5 m/year. The glacier displacement velocities in this region are heavily influenced by climate change and can be important in monitoring and forecasting long-term climate change. However, there are few concrete examples of research in this area. In this study, we applied the improved offset tracking method to observe the two-dimensional velocity in the $Uv{\hat{e}}rsbreen$ glacier. As a result, it was confirmed that the glacier moved at a maximum rate of 133.7 m/year. The measruement precisions for azimuth and line-of-sight directions were 5.4 and 3.3 m/year respectively. These results will be utilized to study long-term changes in elevation of glaciers and to study environmental impacts due to climate change.

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.

Measurement Accuracy for 3D Structure Shape Change using UAV Images Matching (UAV 영상정합을 통한 구조물 형상변화 측정 정확도 연구)

  • Kim, Min Chul;Yoon, Hyuk Jin;Chang, Hwi Jeong;Yoo, Jong Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.25 no.1
    • /
    • pp.47-54
    • /
    • 2017
  • Recently, there are many studies related aerial mapping project and 3 dimensional shape and model reconstruction using UAV(unmanned aerial vehicle) system and images. In this study, we create 3D reconstruction point data using image matching technology of the UAV overlap images, detect shape change of structure and perform accuracy assessment of area($m^2$) and volume($m^3$) value. First, we build the test structure model data and capturing its images of shape change Before and After. Second, for post-processing the Before dataset is convert the form of raster format image to ensure the compare with all 3D point clouds of the After dataset. The result shows high accuracy in the shape change of more than 30 centimeters, but less is still it becomes difficult to apply because of image matching technology has its own limits. But proposed methodology seems very useful to detect illegal any structures and the quantitative analysis of the structure's a certain amount of damage and management.

Software Implementation of Welding Bead Defect Detection using Sensor and Image Data (센서 및 영상데이터를 이용한 용접 비드 불량검사 소프트웨어 구현)

  • Lee, Jae Eun;Kim, Young-Bong;Kim, Jong-Nam
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.185-192
    • /
    • 2021
  • Various methods have been proposed to determine the defect detection of welding bead, and recently sensor data and image data inspection have been steadily announced. There are advantages that sensor data inspection is highly accurate, and two-dimensional-based image data inspection is able to determine the position of the welding bead. However, when analyzing only with sensor data, it is difficult to determine whether the welding has been performed at the correct position. On the other hand, the image data inspection does not have high accuracy due to noise and measurement errors. In this paper, we propose a method that can complement the shortcomings of each inspection method and increase its advantages to improve accuracy and speed up inspection by fusing sensor data inspection which are average current, average volt, and mixed gas data, and image data inspection methods and is implemented as software. In addition, it is intended to allow users to conveniently and intuitively analyze and grasp the results by performing analysis using a graphical user interface(GUI) and checking the data and inspection results used for the inspection. Sensor inspection is performed using the characteristics of each sensor data, and image data is inspected by applying a morphology geodesic active contour algorithm. The experimental results showed 98% accuracy, and when performing the inspection on the four image data, and sensor data the inspection time was about 1.9 seconds, indicating the performance of software that can be used as a real-time inspector in the welding process.

The Study on Accuracy Improvement of Estuary Riverbed Monitoring (하구하상 모니터링 정밀도 향상에 관한 연구)

  • Park, Un-Yong;Kim, Yong-Bo;Back, Ki-Suk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.11 no.3 s.26
    • /
    • pp.23-34
    • /
    • 2003
  • Currently, the efficiency of GPS has been increased in the various precise survey like as the control survey and the navigation etc. Also, it is widely used in the deformation analysis of the structure, the measurement of the marine tides, the measurement of the river level and the topographic monitoring of seabed or riverbed by combined the measurement equipment for depth. In this study, we intend to increase in efficiency of the topographic monitoring of seabed or riverbed by combined with DGPS, RTK GPS and echo sounder. For this study, we defined the error correction of the echo sounder with the experiment of water tank which is considered the characteristic of estuary riverbed and then we developed the s/w for 3-dimensional monitoring of estuary riverbed and applied the s/w to field test and improved the various problems. On analyzing topography of estuary riverbed by combined GPS with echo sounder, the draught error which is yielded to change of length from the water surface by the movement of survey vessel to the end of the transducer was eliminated by geometrical rearrangement and we defined the correction formula $z=BM+SAH-DBR_{(i)}-DRT-ED$. The sounding error about the echo sounder and characteristic of estuary riverbed was found by understanding the relation of average diameter ind residual error and we defined correction formula, $Y=0.00474{\ast}ln(X)-0.0045$ by the regression analysis. and then we verified applicability of correction formula.

  • PDF

Measuring Similarity of Android Applications Using Method Reference Frequency and Manifest Information (메소드 참조 빈도와 매니페스트 정보를 이용한 안드로이드 애플리케이션들의 유사도 측정)

  • Kim, Gyoosik;Hamedani, Masoud Reyhani;Cho, Seong-je;Kim, Seong Baeg
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.13 no.3
    • /
    • pp.15-25
    • /
    • 2017
  • As the value and importance of softwares are growing up, software theft and piracy become a much larger problem. To tackle this problem, it is highly required to provide an accurate method for detecting software theft and piracy. Especially, while software theft is relatively easy in the case of Android applications (apps), screening illegal apps has not been properly performed in Android markets. In this paper, we propose a method to effectively measure the similarity between Android apps for detecting software theft at the executable file level. Our proposed method extracts method reference frequency and manifest information through static analysis of executable Android apps as the main features for similarity measurement. Each app is represented as an n-dimensional vectors with the features, and then cosine similarity is utilized as the similarity measure. We demonstrate the effectiveness of our proposed method by evaluating its accuracy in comparison with typical source code-based similarity measurement methods. As a result of the experiments for the Android apps whose source file and executable file are available side by side, we found that our similarity degree measured at the executable file level is almost equivalent to the existing well-known similarity degree measured at the source file level.

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

Effects of real-time feedback training on weight shifting during golf swinging on golf performance in amateur golfers

  • Hwang, Ji-Hyun;Choi, Ho-Suk;Shin, Won-Seob
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.4
    • /
    • pp.189-195
    • /
    • 2017
  • Objective: The purpose of this study was to examine the effects of real-time visual feedback weight shift training during golf swinging on golf performance. Design: Repeated-measures crossover design. Methods: Twenty-sixth amateur golfers were enrolled and randomly divided into two groups: The golf swing training with real-time feedback on weight shift (experimental group) swing training on the Wii balance board (WBB) by viewing the center of pressure (COP) trajectory on the WBB. All participants were assigned to the experimental group and the control group. The general golf swing training group (control group) performed on the ground. The golf performance was measured using a high-speed 3-dimensional camera sensor which analyses the shot distance, ball velocity, vertical launch angle, horizontal launch angle, back spin velocity and side spin velocity. The COP trajectory was assessed during 10 practice sessions and the mean was used. The golf performance measurement was repeated three times and its mean value was used. The assessment and training were performed at 24-hour intervals. Results: After training sessions, the change in shot distance, ball velocity, and horizontal launch angle pre- and post-training were significantly different when using the driver and iron clubs in the experimental group (p<0.05). The interaction time${\times}$group and time${\times}$club were not significant for all variables. Conclusions: In this study, real-time feedback training using real-time feedback on weight shifting improves golf shot distance and accuracy, which will be effective in increasing golf performance. In addition, it can be used as an index for golf player ability.

A Numerical Simulation on the Process of Diaphragm Opening in Shock Tube Flows (충격파관 유동의 파막과정에 관한 수치 시뮬레이션)

  • Shin, Choon-Sik;Jeong, June-Chang;Suryan, Abhilash;Kim, Heuy-Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • Shock tube flow measurement has been often hampered a finite opening time of diaphragm, but there is no systematic work to investigate its effect on the shock tube flow. In the present study, both the experimental and computational works have been performed on the shock tube flows at low pressure ratios. The computational analysis has been performed using the two-dimensional, unsteady, compressible Navier-Stokes equations, based upon a TVD MUSCL finite difference scheme. It is known that the present computational results reproduce the experimental data with good accuracy and simulate successfully the process of diaphragm opening as a function of time. The concept of an imaginary center is introduced to quantify the non-centered expansion wave due to a finite opening time of diaphragm. The results obtained show that the diaphragm opening time is reduced as the initial pressure ratio of shock tube increases, leading to the effect of a finite opening time of diaphragm to be more remarkable at low pressure ratios.

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.