• 제목/요약/키워드: Dimensional change

검색결과 2,004건 처리시간 0.028초

침적 소독이 고무 인상재의 크기 안정성에 미치는 영향 (THE EFFECT OF IMMERSION DISINFECTION ON THE DIMENSIONAL STABILITY OF RUBBER IMPRESSION MATERIALS)

  • 민권남;방몽숙
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.496-505
    • /
    • 1998
  • The purpose of this study was to evalute the effect of immersion disinfection on the dimensional stability of rubber impression materials. The metallic master model was made in order to simulate the intraoral arch form. Impressions were made from four impression materials (Exaflex, Extrude, Reprosil, Impregum-F) and immersed in three disinfectant solutions (Wydex, Vi-Pon, Potadine). Casts from the impressions were measured according to the interpreparation distance. The A-B and The B-D abutment distance were compared with the control group and disinfected groups. The results were as follows; 1. The measurements of the stone cast increased relative to the master model and there was a significant difference (P<0.05). 2. The relative dimensional change of the stone cast as compared with master model ranged from 0.10% to 0.56% in the A-B distance and ranged from 0.04% to 0.27% in the B-D distance. 3. The dimensional change of the disinfected groups as compared with the control group was significantly different in the three impression materials except for Impregum-F (P<0.05). 4. The relative dimensional change of the disinfected groups compared with the control group ranged from 0% to 0.20% in the A-B distance and ranged from -0.09% to 0.11% in the B-D distance. These results suggest that immersion disinfection of rubber impression materials by chemical disinfectants causes very small dimensional change and the change is clinically acceptable for prothesis fabrication

  • PDF

전악인상채득시 인상용 트레이가 경석고 모형의 정확도에 미치는 영향 (THE INFLUENCE OF IMPRESSION TRAYS ON THE ACCURACY OF THE STONE CASTS POURED FROM COMPLETE-ARCH IMPRESSIONS)

  • 류수인;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제30권1호
    • /
    • pp.1-14
    • /
    • 1992
  • The purpose of this study was to evaluate the accuracy of reproduction of stone casts made from complete-arch impressions using different trays. The trays used were : 1) nonperforated custom tray, 2) perforated custom tray, 3) nonperforated Rim-Lock tray, 4) perforated stock tray. Impressions were made from an dentulous acrylic resin model with metal inserts in first premolars and second molars. Transverse distance, sagittal distance and diagonal distance were measured using 4 landmarks. Measurements were made by using 3 dimensional measuring machine. The impression material used was an addition silicone. Impressions were poured at once with a Type IV dental stone. Data were analyzed using ANOVA and student t-test with a sample size of five. The results were as follows : 1. There were statistical differences in amount of dimensional change in according to the tray types. In amount of mean dimensional change, perforated custom tray was the first smallest, nonperforated custom tray was the second, nonperforated Rim-Lock tray and perforated stock tray were the largest. 2. There were statistical differences in amount of dimensional change between nonperforated custom tray and nonperforated Rim-Lock tray, and between perforated custom tray perforated stock tray. 3. There were satistical differences in amount of dimensional change between nonperforated custom tray and perforated custom tray, but there was not a statistical difference between nonperforated Rim-Lock tray and perforated stock tray. 4. There was not a statistical difference in amount of dimensional change between upper and lower arch in all tray types.

  • PDF

터널 3차원 내공변위의 해석을 통한 막장전방 지반상태변화 예측 (Prediction of Change in Ground Condition Ahead of Tunnel Face Using Three-dimensional Convergence Analysis)

  • 김기선;김영섭;유광호;박연준;이대혁
    • 터널과지하공간
    • /
    • 제13권6호
    • /
    • pp.476-485
    • /
    • 2003
  • 본 연구의 목적은 막장전방에 파쇄대가 존재할 때 터널 3차원 내공변위를 여러 가지 방법으로 해석하여 변위의 변화 경향을 밝히고 지질변화를 예측하는 계측해석기법을 제시하는 것이다. 안정된 지하 암반에 터널을 굴착하게 되면, 터널 막장면을 포함한 무지보 굴착면 주위에 3차원적인 하중전이 현상이 나타나는데 막장 전방의 지반 상태가 변화하거나 연약 파쇠대층이 존재하면 특정한 변위 경향을 보이는 것으로 기존 연구결과 알려져 있다. 터널 천단부 축방향 변위/수직변위 비 등으로부터 터널 막장 전방에서 지반의 강성이 변화하는 불연속면의 존재를 예측할 수 있다. 그러므로, 시공중인 터널 내에서 3차원 절대 내공 변위를 측정하여 본 연구에서 제시된 계측해석 기법을 적용하면 터널 막장 전방의 지층변화나 파쇄대층의 존재를 사전에 예측할 수 있을 것으로 판단된다.

준설토의 체적변화 및 2차원 퇴적특성에 관한 연구 (A Study on the Sediment Volume Change and Two-dimensional Deposited Characteristics of Pumping-dredged Soil)

  • 김형주;이민선;이용주;김대우
    • 한국지반공학회논문집
    • /
    • 제19권4호
    • /
    • pp.155-165
    • /
    • 2003
  • 본 연구는 고함수비의 액상준설토의 체적변화 및 퇴적특성을 파악하기 위해 일련의 실린더침강시험, 침투압밀시험과 2차원퇴적모형실험이 실시되었다. 그리고 실험결과는 실제 준설매립현장의 퇴적상태와 비교됨으로써 설계시에 필요한 침강에 의한 체적변화량을 구할 수 있도록 하였으며, 퇴적후의 세립토의 분포와 함수비 변화 등이 함에 조사되었다. 따라서 1차원 침강시는 실질토량이 증가 할 수록 퇴적고는 선형적으로 증가하며, 자중압밀개시시 및 완료시의 계면고도 또한 실질토량에 비례하여 증가되고 있다. 한편 2차원 퇴적모형실험에 의해 함수비의 분포와 세립토의 퇴적상태를 제시하였으며, 퇴적층의 함수비는 #200체의 통과량에 따라 다르며 최소 30%에서 최대 180%까지 폭넓게 분포되고 있다.

딜라토미터를 이용한 STD11 공구강의 오스테나이징 및 템퍼링 열처리에 따른 치수 변화 이방성 연구 (Study on the Anisotropic Size Change by Austenitizing and Tempering Heat Treatment of STD11 Tool Steel Using Dilatometry)

  • 홍기정;강원국;송진화;정인상;이기안
    • 대한금속재료학회지
    • /
    • 제46권12호
    • /
    • pp.800-808
    • /
    • 2008
  • Heat treatment is an important step for tool manufacture, but unavoidably generates dimensional distortion. This study investigated the continuous dimensional change and the anisotropic behavior of STD11 tool steel during austenitizing and tempering heat treatment especially using quenching dilatometer. Dilatometric results represented that the dimensional change along longitudinal direction was larger than that along transverse direction. Anisotropic phase transformation strain was produced in forged STD11 tool steel during heat treatment. Anisotropic dimensional change increased with increasing austenitizing temperature. After tempering, anisotropic distortion was partially reduced. FactSage thermodynamic equilibrium phase simulation and microstructural observation (FE-SEM, TEM) showed that large ($7{\sim}80{\mu}m$) elongated $M_7C_3$ carbides could be formed along rolling direction. The resolution of elongated carbides during austenitizing was found to be related with the change of martensite transformation temperature after heat treatment. Anisotropic size change of STD11 tool steel was mainly attributed to large elongated carbides produced during rolling process. Using dilatometric and metallographic examination, the possible mechanism of the anisotropic size change was also discussed.

상변화 축열계의 비정상 해석 (A Study on Two Dimensional Phase Change Problem)

  • 원성필;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.12-21
    • /
    • 1981
  • The Enthalpy Model was verified in order to analyze two- dimensional phase change problems. By using the Enthalpy Model, interface locations, frozen fraction rates, heat flux distribution rut cooled surfaces, and surface-integrated heat flux were purely numerically calculated in rectangular thermal storage units, whose initial condition was saturated liquid and phase change material was cooled on its boundaries by convective heat transfer. The calculations were performed for various Stefan numbers and Biot numbers. The effect on those dimensionless numbers were explained.

  • PDF

2롤 교정공정에서 인발선재의 선경변화 (Dimensional Change in Drawn Wire Product in the Two Cross-Roll Straightening Process)

  • 문창선;김낙수
    • 대한기계학회논문집A
    • /
    • 제37권3호
    • /
    • pp.295-302
    • /
    • 2013
  • 상온에서의 2롤 교정공정은 인발선재의 진직도를 향상시키기 위한 가공방법이다. 인발과정에서 생긴 인발선재의 내부 및 외부에 남아 있는 잔류응력은 2롤 교정을 거치면서 변하게 된다. 그에 따라서 인발선재의 선경에도 변화가 생긴다. 인발후 잔류응력이 남아 있는 소재에 대하여 롤사이의 거리(h)와 롤의 교차각도(${\alpha}_u$, ${\alpha}_d$)에 따른 선경변화를 분석하고 최종제품의 잔류응력과 선경변화를 예측하였다. 2롤 교정을 통한 최종제품의 선경변화를 예측해 실험값과 비교 및 검증한 결과 타당한 계산결과를 얻을 수 있었다. 상부롤과 하부롤의 교차각도는 잔류응력과 선경변화에 미치는 영향이 미미하였다. 반면에, 롤사이의 거리(h)는 잔류응력과 선경변화에 영향을 미치는 것을 확인하였다.

미세성형품의 정밀 냉간단조시 치수변화 분석 (Dimensional change of micro forged part on precision cold forging)

  • 이명원;이영선;이정환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 추계학술대회 논문집
    • /
    • pp.254-258
    • /
    • 2008
  • Dimensional accuracy is very important quality in micro forged part, especially on forged part. Dimension of forged part is changed continuously during forging process. Loading, unloading and ejecting stage affects dimensional of the forged tool. The elasto-plastic material model for billet and elastic model for die were used to analyze these changes. At same time, the calculated results were compared and analyzed by the experiment on same conditions. From the experimental and analytical studies, we can calculated the amount of difference between die and forged part, that is 0.49% based on the die dimension. The dimensional change is smaller than that of general sized-forged part,0.6%.

  • PDF

A Study on Development of the Three-Dimensional Numerical Model to Analyze the Casting Process: Mold Filling and Solidification

  • Mok Jinho
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1488-1502
    • /
    • 2005
  • A three dimensional model was developed to analyze the mold filling and solidification in the casting processes. The model uses the VOF method for the calculation of the free surface and the modified Equivalent Specific Heat method for the treatment of the latent heat evolution. The solution procedure is based on the SIMPLER algorithm. The complete model has been validated using the exact solutions for phase change heat transfer and the experimental results of broken water column. The three-dimensional model has been applied to the benchmark test and the results were compared to those from experiment, a two-dimensional analysis, and another three dimensional numerical model.

아기-알지네이트 연합 인상체의 보관방법 및 idophor 침적소독에 의한 체적 변화에 관한 연구 (AGAR-ALGINATE COMBINED IMPRESSION TECHNIQUE AND DIMENSIONAL CHANGE RESULTING FROM IDOPHOR DISINFECTION)

  • 오남식;서정민;김선희;윤영아;심준성
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.21-29
    • /
    • 2004
  • Statement of problem : Because dental impression can be a cross-infection source, disinfection, such as immersion disinfection is nessecary. However, the disinfection process may change the volume of the impression cast. Purpose : The purpose of this study is to find out the effects on dimensional change of different storage times and methods, of agar-alginate impression when immersed in a 5% idophor disinfectant. Material and Methods : An agar-alginate impression was made from a mandible model and then was disinfected and stored according the experimental conditions and a stone model was produced. Measurements were taken between reference points on the original mandible model and they were compared to measurements taken between reference points on the stone model. The study was divided into 4 groups. In group 1, the impression was stored in a 100% humidor for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours and 24 hours and stone models were made at each time. In group 2, the impression was immersed in 5% idophor disinfectant and then stored in a 100% humidor for the same length of times as group 1, and stone models were made at each time. In group 3, the impression was stored in extend-A-pourR, a special storage solution for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours, 24 hours 3 days, and 7 days and stone models were made at each time. In group 4, the impression was immersed in 5% idophor disinfectant and then stored in stored in extend-A-pourR, a special storage solution for the same length of times as group 3, and stone models were made at each time. 5 impressions and stone models were made at each time to make a total of 180. The Student-t test (P < .05) was used to do a statistical analysis of the measurements of the mandible model and stone models. The repeated-measure 2-way analysis of variance (P < .05) was used to do a statistical analysis of the difference in the 4 groups. Results : The percent liner dimensional change was from $0.25{\pm}0.03%$ (group 1, 30 minutes) to $0.34{\pm}0.06%$ (group 4, 7 days). No significant change was noticed between the 4 groups. Conclusion : According to the above study, in both methods, least dimensional change was recorded when the storage times were short and in both methods, immersion in 5% idophor disinfectant did not effect dimensional change in the agar-alginate impression.