• Title/Summary/Keyword: Dimensional Error Rate

Search Result 212, Processing Time 0.031 seconds

An Positioning Error Analysis of 3D Face Recognition Apparatus (3차원 안면자동인식기의 Positioning 오차분석)

  • Kwak, Chang-Kyu;Cho, Yong-Beum;Sohn, Eun-Hae;Yoo, Jung-Hee;Kho, Byung-Hee;Kim, Jong-Won;Kim, Kyu-Kon;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.2
    • /
    • pp.34-40
    • /
    • 2006
  • 1. Objectives We are going to develope 3D Face Recognition Apparatus to analyse the facial characteristics of the Sasangin. In the process, we should identify the recognition rate of the three dimensional position using this Apparatus. 2. Methods We took a photograph of calibrator($280{\times}400mm$) with interval of 20mm longitudinal direction of 10 times using 3D Face Recognition Apparatus. In the practice, we obtained 967 point to the exclusion of points deviating from the visual field of dual camera. And we made a comparison between measurement values and three dimensional standard values to calculate the errors. 3. Results and Conclusions In this test, the average error rate of X axis values was 0.019% and the maximum error rate of X axis values was 0.033%, the average error rate of Y axis values was 0.025% and the maximum error rate of Y axis values was 0.044%, the average error rate of Z axis values was 0.158% and the maximum error rate of Z axis values was 0.269%. This results exhibit much improvement upon the average error rate 1% and the maximum error rate 2.242% of the existing 3D Recognition Apparatus. In conclusion, we assessed that this apparatus was adaptable to abstract the facial characteristic point from three dimensional face shape in the mechanical aspects.

  • PDF

Parallel Writing and Detection for Two Dimensional Magnetic Recording Channel

  • Zhang, Yong;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37A no.10
    • /
    • pp.821-826
    • /
    • 2012
  • Two-dimensional magnetic recording (TDMR) is treated as the next generation magnetic recording method, but because of its high channel bit error rate, it is difficult to use in practices. In this paper, we introduce a new writing method that can decrease the nonlinear media error effectively, and it can also achieve 10 Tb/$in^2$ of user bit density on a magnetic recording medium with 20 Teragrains/$in^2$.

A study on 1 & 2 dimensional minimum mean-squared-error equalization for digital holographic data storage system (디지털 홀로그래픽 데이터 저장 시스템을 위한 1차원 및 2차원 최소 평균-제곱-에러 등화에 관한 연구)

  • 최안식;전영식;정종래;백운식
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.6
    • /
    • pp.486-492
    • /
    • 2002
  • In this paper. we presented 1 & 2 dimensional minimum mean-squared-error (MMSE) equalization scheme in a digital holographic data storage system to improve bit-error-rate (BER) and to mitigate inter-symbol interference (ISI) which were generated during the data storage and retrieval processes. We showed experimentally for ten data pages retrieved from the holographic storage system that BER and signal-to-noise ratio (SNR) were improved by adopting MMSE equalization.

A lower bound of bit error rate of chip asynchronous Pattern codes in 2-dimensional optical CDMA system (2차원 광부호분할 다중접속 시스템에서 칩 비동기 패턴부호의 비트오류율 하한값 유도)

  • Lee, Tae-Hoon;Park, Young-Jae;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3239-3241
    • /
    • 1999
  • Two-dimensional optical code-division multiple access is a system to transmit a two- dimensional data via parallel transmission line. The probability density function (pdf) of interference noise from other users is calculated and the pdf of asynchronous interference noise is newly calculated to present lower bounds of probability of error. The corresponding bit error rate is evaluated from this results.

  • PDF

Error-Correcting 7/9 Modulation Codes For Holographic Data Storage

  • Lee, Kyoungoh;Kim, Byungsun;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.2
    • /
    • pp.86-91
    • /
    • 2014
  • Holographic data storage (HDS) has a number of advantages, including a high transmission rate through the use of a charge coupled device array for reading two-dimensional (2D) pixel image data, and a high density capacity. HDS also has disadvantages, including 2d intersymbol interference by neighboring pixels and interpage interference by multiple pages stored in the same holographic volume. These problems can be eliminated by modulation codes. We propose a 7/9 error-correcting modulation code that exploits a Viterbi-trellis algorithm and has a code rate larger (about 0.778) than that of the conventional 6/8 balanced modulation code. We show improved performance of the bit error rate with the proposed scheme compared to that of the simple 7/9 code without the trellis scheme and the 6/8 balanced modulation code.

Numerical modeling of underwater explosion phenomena (수중 폭발현상에 대한 전산해석)

  • Lee Jaimin;Kuk Jeong-Hyun;Choi Kyung Young;Cho Yong Soo;Song So-young
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1998.05a
    • /
    • pp.1-14
    • /
    • 1998
  • Underwater explosion properties for TNT, an ideal explosive, and DXD-04, a nonideal explosive, were numerically modeled with a one-dimensional Lagrangian hydrodynamic code. The equation of state parameters for detonation products for TNT and DXD-04 were obtained from the BKW code, assuming complete reaction. Burn of TNT was modeled by using the Chapman-Jouguet(CJ) volume burn technique, a programmed-burn technique, assuming instantaneous detonation reaction. Burn of DXD-04 was modeled by using the same technique and by using the reaction rate calibrated from two-dimensional steady-state detonation experiments. The calculations for TNT reproduced the experimental peak pressure of the shock wave propagating through water with an error of $3.0\%$ and the experimental oscillation period of the bubble formed of detonation products with an error of $2.3\%$. For DXD-04, the CJ volume burn technique could not reproduce the experimental observations. When the reaction rate calibrated from two-dimensional steady-state detonation experimental data, the calculated peak pressure was slightly higher by $7.3\%$ than the experimental data, but the calculated shock profile was in good agreement. The bubble period was reproduced with an error of $1.8\%$. These results demonstrated that underwater explosion properties for an ideal explosive can be predicted by using a programmed burn technique, and that, however, those for a nonideal explosive can be predicted only when a well-calibrated reaction rate is used.

  • PDF

Two-Dimensional 8/9 Error Correcting Modulation Code

  • Lee, Kyoungoh;Kim, Byungsun;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.5
    • /
    • pp.215-219
    • /
    • 2014
  • In holographic data storage (HDS), a high transmission rate is accomplished through the use of a charge coupled device array for reading two-dimensional (2D) pixel image data. Although HDS has many advantages in terms of storage capacity and data transmission rates, it also features problems, such as 2D intersymbol interference (ISI) by neighboring pixels and interpage interference (IPI) by multiple images stored in the same holographic volume. Modulation codes can be used to remove these problems. We introduce a 2D 8/9 error-correcting modulation code. The proposed modulation code exploits the trellis-coded modulation scheme, and the code rate is larger (about 0.889) than that of the conventional 6/8 balanced modulation code (an increase of approximately 13.9%). The performance of the bit error rate (BER) with the proposed scheme was improved compared with that of the 6/8 balanced modulation code and the simple 8/9 code without the trellis scheme.

Discrete Wavelet Transform for Watermarking Three-Dimensional Triangular Meshes from a Kinect Sensor

  • Wibowo, Suryo Adhi;Kim, Eun Kyeong;Kim, Sungshin
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.14 no.4
    • /
    • pp.249-255
    • /
    • 2014
  • We present a simple method to watermark three-dimensional (3D) triangular meshes that have been generated from the depth data of the Kinect sensor. In contrast to previous methods, which maintain the shape of 3D triangular meshes and decide the embedding place, requiring calculations of vertices and their neighbors, our method is based on selecting one of the coordinate axes. To maintain shape, we use discrete wavelet transform and constant regularization. We know that the watermarking system needs the information to be embedded; we used a text to provide that information. We used geometry attacks such as rotation, scales, and translation, to test the performance of this watermarking system. Performance parameters in this paper include the vertices error rate (VER) and bit error rate (BER). The results from the VER and BER indicate that using a correction term before the extraction process makes our system robust to geometry attacks.

A Two-Dimensional Pseudo-balanced Code for Holographic Data Storage Systems (홀로그래픽 데이터 저장 시스템을 위한 2차원 코드)

  • Kim, Na-Young;Lee, Jae-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.11C
    • /
    • pp.1037-1043
    • /
    • 2006
  • In this paper, we introduce a two-dimensional modulation code for holographic data storage systems(HDSS), which is a candidate for the next generation data storage system. The two-dimensional(2D) intersymbol interference(ISI) induces higher bit error rate(BER). The balanced number of zeros(dark) and ones(light) in each page reduces inter-page interference(IPI). The code rate is 519. Although the proposed code has higher code rate than other 2D code with rate 4/9, the BER performances of two codes are similar.

Asymptotic Expressions for One Dimensional Model of Hemodiafiltration

  • Chang, Ho-Nam;Park, Joong-Kon
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 1984
  • The asymptotic solution using the Tailor series has been given explicit form for the solute concentration and overall solute removal in hemodiafilter using one dimensional model. The numerical solutions have been calculated within 0.001% error by the Romberg integration method. Compared with the numerical solutions, the oneterm asymptotic solutions were found to be within 3% error for the condition > 3.0 and three-terms asymtotic solutions were required for the condition >0.7 where denotes measure of convection over diffusional transport and a the ratio of blood flow rate over dialysate flow rate.

  • PDF