• 제목/요약/키워드: Dimension stability

검색결과 242건 처리시간 0.027초

수종 인상재의 침지 소독이 경석고 모형의 크기 안정성에 미치는 영향에 관한 연구 (A STUDY ON DIMENSIONAL STABILITY OF IMPRESSION MATERIALS FOLLOWING IMMERSION DISINFECTION)

  • 송기용;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.506-515
    • /
    • 1999
  • Dental practice can produce and spread some infectious diseases from patients to dentist, dental assistant, and dental labors. One possible method for preventing these cross-contamination is to immerse dental impression in chemical disinfectants. So for many investigators studied on the dimensional changes of dental impressions and on the surface qualities of stone casts made from impression following immersion in disinfectants. This study was proposed to evaluate some popular impression disinfectant combination from the point of dimensional stability. Impression was taken from dental arch-shaped metal model. Irreversible hydrocolloid and 3 elastomers(polyvinyl siloxane, polysulfide, polyether) were immersed in 3 disinfectants (2% glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite) for 10 minutes and measured both cross-arch and anterior-posterior distance under stereo microscope to evaluate dimensional change. The results obtained were as follows: 1. Dimensional changes of irreversible hydrocolloid impression was statistically different in cross-arch and anterior-posterior distance when immersed in 2% glutaraldehyde solution and in anterior-posterior distance when immersed in 0.5% sodium hypochlorite solution from control group (p<0.05). 2. Dimensional changes of polyvinyl siloxane and polysulfide impression were not statistically different from control group (p>0.05). 3. Dimensional changes of polyether impression was statistically different in cross-arch distance when immersed in 0.5% sodium hypochlorite solution and in anterior-posterior distance when immersed in 1% povidone-iodine solution from control group (p<0.05). 4. In all cases, dimensional changes were less than 0.1% from the original dimension and concluded clinically acceptable.

  • PDF

Experimental Studies on Swirling Flow in a Vertical Circular Tube

  • Chang, Tae-Hyun;Lee, Chang-Hoan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.907-913
    • /
    • 2011
  • Swirling flows are related to the spiral motion in the tangential direction in addition to the axial and radial direction using several swirl generators. These type of flows are used in combustion chambers to improve flame stability, heat exchanger to enhance heat transfer coefficients, agricultural spraying machines and some vertical pipes to move slurries or transport of materials. However, only a few studies three dimensional velocity profiles in a vertical pipe have been reported. In this present paper, 3 dimension particle image velocimetry(PIV) technique was employed to measure the velocity profiles in water along a vertical circular pipe with Reynolds number from 6000 to 13,000. A tangential inlet condition was used as the swirl generator to produce the required flow. The velocities were measured with swirling flow in the water along the test section using the PIV technique.

메움벽에 의한 R/C 골조의 내진성능 평가에 관한 연구 (Experimental Study of Infilled Wall in Reinforced Concrete Structure)

  • 김석균;김정한;김영문
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.403-406
    • /
    • 1999
  • Although infilled wall considered as a non-structural element, the infilled applied in reinforced concrete frame structural systems represents an important element influencing the behaviour and the stability of a structure under seismic effect. This research is performed an experimental investigation of gravity-load designed single-stroy, single-bay, low-rise nonseismic moment-resisting reinforced concrete frame 2 dimension specimens to evaluate the effect of seismic capacity. For pseudo static test, it was manufactured one half scale specimens of two types (Bare Frame, Infilled Frame) based on typical building. The results of these experiments provided regarding the global as well as the local responses of 1) Crack pattern and failure modes, 2) Stiffness, strength.

  • PDF

특성함수를 이용한 제한조건이 있는 천장크레인의 강건최적설계 (Robust Optimization Design of Overhead Crane with Constraint using the Characteristic Functions)

  • 홍도관;최석창;안찬우
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.160-167
    • /
    • 2004
  • The correlation between the object function and the design parameter is shown on this paper by using the characteristic function for the mixed result of the structural analysis, the buckling analysis and the table of orthogonal array according to the original overhead crane's dimensional change. About the above two functions, the effectiveness of design change according to the change of design parameters could be estimated. Also, the overhead crane's weight is reduced up to 10.55 percent maintaining the structural stability according to the thickness of plate.

고분자 전해질 연료전지용 복합수지 분리판 개발 (Development of Composite Bipolar Plate for PEMFC)

  • 강현민;한인수;임찬
    • 신재생에너지
    • /
    • 제3권4호
    • /
    • pp.3-7
    • /
    • 2007
  • Graphite/polymer composite bipolar plates for PEMFC are successfully developed, and their typical properties are superior to commercially available ones. Thermal property of the developed bipolar plate was evaluated by dynamic mechanical analyzer, and the results were compared to commercial ones. The specimens were immersed into the deionized water bath at $80^{\circ}$... for 1500hrs to evaluate dimensional stability and durability. Dimension, weight of the specimens as well as extraction conductivity was measured as each 500hrs. Fully molded bipolar plates without any machining or milling were also prepared using a specially developed mold, and they were applied to the fuel cell performance test. Results were compared to the machined commercial bipolar plate.

  • PDF

TFT LCD 제조용 대면적 Magnetron Sputtering 장치 설계와 Al 성장막 특성 조사 (Design of a Large Magnetron Sputtering System for TFT LCD and Investigation of Sputtered AI Film Properties)

  • 유운종
    • 한국진공학회지
    • /
    • 제2권4호
    • /
    • pp.480-485
    • /
    • 1993
  • Factros considered building the magnetron sputtering system for TFT LCD (thin film transistor liquid crystal display0 metallization were thin film thichnes uniformity, temperature uniformity and the pressure gradient of sputtering gas flow in vacuum chamber, base pressure, and the stability fo the carrier moving . The system was consisted of a deposition chamber, a pre-heating chamber, a RF-precleaning chamber and a load/unload lock chamber. The system was designed to handle a substrate with dimension of 400$\times$400mm. The temperautre uniformity of a heater table developed showed $250 ^{\circ}C\pm$5% accuracyon the substrate glass. A base pressure of 1.8 $\times$10-7 torr was obtained after 24 hours pumping with a cryo pump. After an aluminum target was installed in a sputtering source and the film wa sdeposited on the glass, the uniformity, reflectivity and sheet resistance of the deposited film were measured.

  • PDF

권상용량 증가에 따른 컨테이너 크레인의 내풍특성 비교 (A Comparison of the Wind Resistance Characteristic of a Container Crane According to the Increase to the Lifting Capacity)

  • 이성욱;김형훈;한동섭;한근조;김태형
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.204-209
    • /
    • 2007
  • This study was carried out to analyze the effect of wind load on the structural stability of a container crane according to the increase of the lifting capacity using wind tunnel test and provided a container crane designer with data which can be used in a wind resistance design of a container crane assuming that a wind load at 75m/s wind velocity is applied on a container crane. Data acquisition conditions for this experiment were established in accordance with the similarity. The scale of a container crane dimension, wind velocity and time were chosen as 1/200, 1/13.3 and 1/15. And this experiment was implemented in an Eiffel type atmospheric boundary-layer wind tunnel with $11.52m^{2}$ cross-section area. Each directional drag and overturning moment coefficients were investigated.

  • PDF

강우로 인한 사면 불안정 (Slope Instability Due to Rainfall)

  • 김상규;김영묵
    • 한국지반공학회지:지반
    • /
    • 제7권1호
    • /
    • pp.53-68
    • /
    • 1991
  • 이 논문은 강우가 시작된 후 시간의 경과에 따른 불구화 지반에서의 여러가지 침투거동을 밝혀서, 서면 불안정의 구체적인 머케니즘을 이해하려는데 목적이 있다. 이를 위해 강우장치를 만들어 권쬐요면에 대해 여러가지 강도의 강우를 재현하고 침투거동을 측정하는 한편, 실험에서 사용한 동일한 수치권을 가지고 수치 해석을 하였다. 두가지 모델시 험 의 결과로부터 만윤전선이 진행되는 과정,지반으로 침투되는 한계강우량의 존재,지표류출의 영향,시간의 경과에 따른 간극수압의 변화 등을 밝혀서 이들 인자들이 사면 불안정에 어떻게 영향을 끼치는가를 자세히 언급하였다.

  • PDF

직교배열표와 유한요소해석을 이용한 크레인의 치수최적설계 (The Size Optimization Design of Crane using the Table of Orthogonal Array and Finite Element Analysis)

  • 홍도관;최석창;안찬우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1471-1474
    • /
    • 2003
  • The correlation between the object function and the design parameter is shown on this paper by using the characteristic function for tile mixed result of the structure analysis. tile buckling analysis and the table of orthogonal array according to the original crane's dimensional change. About the above two object functions, the effective of design change according to the change of design parameters could be estimated. Also, the crane's weight is reduced up to 20.58 percent maintaining the structural stability according to the thickness of plate.

  • PDF

고분자 전해질 연료전지용 복합수지 분리판 개발 (Development of Composite Bipolar Plate for PEMFC)

  • 강현민;한인수;임찬
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.5-7
    • /
    • 2007
  • Graphite/polymer composite bipolar plates for PEMFC are successfully developed, and their typical properties are superior to commercially available ones. Thermal property of the developed bipolar plate was evaluated by dynamic mechanical analyzer, and the results were compared to commercial ones. The specimens were immersed into the deionized water bath at $80^{\circ}C$ for 1500hrs to evaluate dimensional stability and durability. Dimension, weight of the specimens as well as extraction conductivity was measured as each 500hrs. Fully molded bipolar plates without any machining or milling were also prepared using a specially developed mold, and they were applied to the fuel cell performance test. Results were compared to the machined commercial bipolar plate.

  • PDF