• Title/Summary/Keyword: Dilution

Search Result 2,382, Processing Time 0.035 seconds

A Study on the River Discharge Measurement Techniques (하천유량 측정기법에 관한 연구)

  • 김성원;지홍기
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.793-801
    • /
    • 1998
  • In this study, the Dilution Method is used to measure river discharge through the hydraulic model test. the dilution method is divided into Constant-Rate-Infection Method and Slug-Injection Method in the river discharge measurement techniques. When the dilution method is applied in the hydraulic model flume, it is analyzed that the estimated error of constant-rate-injection method is less than that of the slug-in-jection method, and the result shows that floodflow analysis is more efficient than lowflow analysis as compared observed discharge with calculated discharge. The result of statistical error analysis shows that the constant-rate-injection method is appropriate technique for the measurement of the river discharge. Therefore, the dilution method among the river discharge measurement techniques can be applied for the river basin which can't be measured with current meter or unsteady-flow regime in the urban-small drainage or hydraulic structure equipment area and can be obtained more exact results than any other discharge measurement techniques.

  • PDF

Estimation in Group Testing when a Dilution Effect exists

  • Kwon, Se-Hyug
    • Communications for Statistical Applications and Methods
    • /
    • v.13 no.3
    • /
    • pp.787-794
    • /
    • 2006
  • In group testing, the test unit consists of a group of individuals and each group is tested to classify units from a population as infected or non-infected or estimate the infection rate. If the test group is infected, one or more individuals in the group are presumed to be infected. It is assumed in group testing that classification of group as positive or negative is without error. But, the possibility of false negatives as a result of dilution effects happens often in practice, specially in many clinical researches. In this paper, dilution effect models in group testing are discussed and estimation methods of infection rate are proposed when a dilution effect exists.

EVALUATION OF TECHNIQUES FOR ESTIMATING MILK PRODUCTION BY SOWS 1. DEUTERIUM OXIDE DILUTION METHOD FOR ESTIMATING MILK INTAKE BY PIGLETS

  • Prawirodigdo, S.;King, R.H.;Dunkin, A.C.;Dove, H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.3 no.2
    • /
    • pp.135-141
    • /
    • 1990
  • Two experiments were conducted to determine the validity of the deuterium oxide ($D_2O$) dilution method to estimate milk intake by pigs. A total of 39 piglets weaned from their dams 24 - 36 hours after birth and trained to drink from artificial nipples, were used for two experiments. Estimates of milk replacer consumption of individual piglets over 1, 3, 5 and 7 days were made by the $D_2O$ dilution method and by dissappearance. Milk intakes estimated by this $D_2O$ dilution method were significantly correlated ($R^2$ = 0.98-0.99) with milk intake measured by disappearance. The average difference between estimates by disappearance and estimates by the $D_2O$ dilution method were -1%, +0.5%, +0.5% and -2.1% for measurement period of 1, 3, 5 and 7 days respectively.

Combustion characteristics of coaxial diffusion flame with preheated air temperature and dilution level (예열공기온도와 희석비율에 따른 동축 확산 화염의 연소 특성)

  • Kim, Jin-Sik;Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • 한국연소학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.51-56
    • /
    • 2001
  • An experiment using preheated air in the coaxial diffusion flame burner was carried out in order to decrease NOx emission and improve the thermal efficiency. Preheated air combustion generally produces high NOx emissions but it was known very well to reduce NOx emission by diluting the combustion air with inert gas in preheated air combustion. In our study, $N_2$ gas was used for diluent and propane was utilized for fuel. We set the combustion air temperature on 300K, 500K, 700K, 900K and dilution level from 21% to 10% in terms of oxygen concentration. NOx emission increased along increment of combustion air temperature and decreased along increment of dilution level(lowering of oxygen concentration in combustion air). Flame-off limit with dilution level enhanced, flame length became longer and the location of maximum flame temperature became lower with increasing of combustion air temperature.

  • PDF

Effect of dilution on micro hardness of Ni-Cr-B-Si alloy hardfaced on austenitic stainless steel plate for sodium-cooled fast reactor applications

  • Balaguru, S.;Murali, Vela;Chellapandi, P.;Gupta, Manoj
    • Nuclear Engineering and Technology
    • /
    • v.52 no.3
    • /
    • pp.589-596
    • /
    • 2020
  • Many components in the assembly section of Sodium-cooled Fast Reactor are made of good corrosionresistant 316 LN Stainless Steel material. To avoid self-welding of the components with the coolant sodium at elevated temperature, hardfacing is inevitable. Ni-based colmonoy-5 is used for hardfacing due to its lower dose rate by Plasma Transferred Arc process due to its low dilution. Since Ni-Cr-B-Si alloy becomes very fluidic while depositing, the major height of the weld overlay rests inside the groove. Hardfacing is also done over the plain surface where grooving is not possible. Therefore, grooved and ungrooved hardfaced specimens were prepared at different travel speeds. Fe content at every 100 ㎛ of the weld overlay was studied by Energy Dispersive Spectroscopy and also the micro hardness was determined at those locations. A correlation between iron dilution from the base metal and the micro hardness was established. Therefore, if the Fe content of the weld overlay is known, the hardness at that location can be obtained using the correlation and vice-versa. A new correlation between micro hardness and dilution coefficient is obtained at different locations. A comparative study between those specimens is carried out to recommend the optimum travel speed for lower dilution.

Determination of Li by Isotope Dilution Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.;Chung, Bag S.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.427-434
    • /
    • 1995
  • Inductively coupled plasma mass spectrometry combined with the isotope dilution method is used for the determination of lithium. The isotope dilution method is based on the addition of a known amount of enriched isotope (spike) to a sample. The analyte concentration is obtained by measuring the altered isotope ratio. The spike solution is calibrated through so called reverse isotope dilution with a primary standard. The spike calibration is an important step to minimize error in the determined concentration. It has been found essential to add spike to a sample and the primary standard so that the two isotope ratios should be as dose as possible. Since lithium is neither corrosive nor toxic, lithium is used as a chemical tracer in the nuclear power plants to measure feedwater flow rate. 99.9% $^7Li$ was injected into a feedwater line of an experimental system and sample were taken downstream to be spiked with 95% $^6Li$ for the isotope dilution measurements. Effects of uncertainties in the spike enrichment and isotope ratio measurement error at various spike-to-sample ratios are presented together with the flow rate measurement results in comparison with a vortex flow meter.

  • PDF

EVALUATION OF SODIUM DICHLOROISOCYANURATE AS A ROOT CANAL IRRIGATION SOLUTION;Cl- CONCENTRATION, pH, CYTOTOXICITY AND ANTIMICROBIAL EFFECT IN VITRO (이염화이소시아뉼산나트륨 제재의 근관세척액 사용 가능성 평가;염소이온농도, 세포독성, 항균성 및 pH)

  • Lee, Woo-Cheol;Kang, Bong-Sun;Kim, Cheol-Ho;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.425-430
    • /
    • 2003
  • The purpose of this study was to evaluate the clinical applications of the Sodium Dichloroisocyanurate effervescent tablet as a routine root canal irrigant by performing several in vitro tests such as $Cl^{-}$ content. cytotoxicity. antimicrobial effect as well as its pH level compared to the equivalent concentration of sodium hypochlorite solution. 1. Sodium Dichloroisocyanurate demonstrated lower level of $Cl^{-}$ concentration than each dilution of sodium hypochlorite solution. Both solution has increased level of $Cl^{-}$ as the concentration of each solution increased. There was no significant change of $Cl^{-}$ concentration in sodium hypochlorite as time goes by. However. $Cl^{-}$ concentration in Sodium Dichloroisocyanurate was increased. 2. The antimicrobial effects of both solutions were increased when their concentrations were increased. One day after dilution. antimicrobial effect of Sodium Dichloroisocyanurate was slightly higher than sodium hypochlorite. however. there was no difference in 1 week dilution solution. One month dilution solution of sodium hypochlorite still retain its activity. but antimicrobial effect of Sodium Dichloroisocyanurate was drastically decreased 1 month after dilution. 3. The cytotoxicity of Sodium Dichloroisocyanurate was rather higher than same concentration of sodium hypochlorite solution until 1 week after dilution. Then in 1 month. cytotoxicity of Sodium Dichloroisocyanurate was decreased than that of 1 week dilution solution. especially 4% Sodium Dichloroisocyanurate solution has almost no toxicity. However. 1% and 2% sodium hypochlorite solution has unchanged moderate degree of cytotoxicity after the dilution. Furthermore. 4% sodium hypochlorite solution showed high level of toxicity. 4. The pH level of Sodium Dichloroisocyanurate showed that the solution was weak acid (pH5). On the other hand. sodium hypochlorite was revealed as a strong alkaline solution (pH12). There was no change in pH following the dilution of each solution. As results. Sodium Dichloroisocyanurate solution fully satisfy the basic requirements as a root canal irrigation solution. However. we strongly recommend to use this solution clinically in low concentration and try to apply into the root canal within 1 week after dilution.

The Study on the Production Method of Stepwise Dilution Gas for Odor Analysis with Orifice Tubes (오리피스 튜브에 의한 단계별 냄새 분석용 희석가스의 제조방법에 관한 연구)

  • Kim, Han-Soo;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • This study is to develop the production method of stepwise dilution gas for the evaluation of complex odor concentration by orifice tube. The basic orifice tube for 10 and 30 times of dilution sample was made at first, and with the combination of the basic orifice tubes we can continuously manufacture the stepwise dilution sample gas for air dilution sensory test ; 10, 30, 100, 300, 1,000, 3,000 times etc. The hole size of orifice tube was 0.84 mm for 10 times of dilution sample, and was 0.34 mm for 30 times. Dilution sample gas made with the basic orifice tube have an excellent reproducibility, 2%RSD. In addition, over 90% of correlation was shown between the sample made by the orifice tube and the sample by the syringe dilution method. Because there was no concentration drift of dilution gas with changes of connected pump flow, the basic orifice tube could be mounted directly with a vacuum suction box, and could be used simply as a tool for the evaluation of odor, especially on site.

Prediction of Near-Field Dilution Changes Due to Treatment Capacity Expansion of Masan-Changwon Municipal Wastewater Treatment Plant (마산.창원 하수종말처리장 증설에 따른 근역희석률변화 예측)

  • 유승협
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.12 no.2
    • /
    • pp.53-69
    • /
    • 2000
  • For the case of the capacity increase of Masan-Changwon wastewater treatment plant, the changes of near-field dilution rates due to the increased discharges into Masan Bay from the submerged multipart-diffuser were predicted by using CORMIX model. As the increase of wastewater discharges from currently 280,000 m3f day to 720,000 m3fday by 2011, the dilution rates become much lower than the present rates. To enhance the reduced dilution rates, the engineering design changes of diffuser length and alignment were considered as an optimal engineering option. According to the results of the model simulations for these changes, the dilution rates were increased in the strong ambient current of spring tide, but they were not affected by these changes in the weak current of neap tide in Masan Bay. From the analysis of oceanographic survey data, new outfalls sites have been searched. A promising outfalls site is selected and proposed on the basis of maximum obtainable dilution rates predicted by the model simulations.

  • PDF

Minimum Dilution of Vertical Multijet Discharging into Stagnant Water (정지수체로 방류된 연직다중\ulcorner㈏\ulcorner최소희석률)

  • Kim, Hong-Sik;Seo, Il-Won;Yu, Dae-Yeong;Seo, Yong-Won
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.2
    • /
    • pp.153-162
    • /
    • 1999
  • In this study, mixing and dilution characteristics of vertical multijet discharged by multiport diffuser into stagnant water are investigated. The results obtained from the experiment of multiport diffuser performed in the three dimensional flume are as follows. As far as merging process of multiport diffuser is concerned, merging starts at about z/l = 3 although merging length is dependent upon stability condition and thereafter lateral temperature distribution becomes gradually uniform which is typical distribution of plane jet. Analyses of experimental data for minimum dilution show that characteristics of minimum dilution are described based on three regions which are jet region where momentum is dominated, intermediate region, and plume region where buoyancy is dominated. Minimum dilution coefficient in plume region of multiport diffuser obtained in this study is 15% higher than that of plane diffuser. This is because individual jet of multiport diffuser entrains more ambient water before merging is occurred, and therefore dilution increases.

  • PDF