• Title/Summary/Keyword: Digitizer

Search Result 92, Processing Time 0.032 seconds

The simulation for error analysis of a large scale laser digitizer system

  • Fujimoto, Ikumatsu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10b
    • /
    • pp.440-445
    • /
    • 1993
  • A two dimensional large scale laser digitizer with a cordless cursor was developed. The coordinate detecting scheme of this digitizer is fundamentally based on the triangulation method, in which two laser-rays are scanned by the rotating plane mirros, reflected backward by the cursor, reflected again by the rotating mirrors, and detected by optical sensors. From angles in which the cursor reflections are detected, we can determine the position of the cursor. But this method involves several problems about optical alignment and its calibration especially when it is applied to a large scale digitizer. In this paper, especially we propose simulation for error analysis with connection to angles measured at five control points which are needed to decide an appropriate model for calculating coordinates and optimal simulation for deciding the position of five control points to give the better coordinate accuracy. In this way, we realized the on-site calibration and on-site insurance of measurement accuracy with our appropriate model for calculating coordinates. The time required for on-site calibration is within 5 minutes and the average accuracy of 4m * 3m digitizer is about .+-.0.12mm.

Development of super large size laser digitizer system

  • Saito, Norio;Hirose, Toshiyuki;Abe, Makoto;Suvama, Masahiro;Fujimoto, Ikunatu;Koizumi, Shinichi;Yaname, Ryuichi;Murakami, Azuma
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1200-1203
    • /
    • 1990
  • Recently, the CAD/CAM system to automatically design and process are used in almost every industry world. We designed an original digitizer system to digitize a real size car drawing. We succeeded in the development of super large size Laser Digitizer System (LDS) which has input area of 2m by 6m, resolution of 0.1mm and accuracy of .+-.0.5mm. This Laser Digitizer System can use in design of cars, ships, planes and big maps. Also can use in sensing the position of nozzle head of laser processing system, and so on.

  • PDF

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.

On a new laser digitizer system

  • Fujimoto, Ikumatsu;Takahashi, Daisuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1646-1648
    • /
    • 1991
  • new system of a two dimensional large scale laser digitizer with a cordless cursor is proposed-it provides an easiness of setting devices and a high accuracy of measurement.

  • PDF

Development of a Simple Computer Vision System (컴퓨터 시각 장치의 개발)

  • 박동철;석민수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.20 no.1
    • /
    • pp.1-6
    • /
    • 1983
  • To give the recognition capability of task objects by computer vision to a sensor-based robot system, an image digitizer and some basic software techniques were developed and repofted here. The image digitizer was developed with the CROMEMCO SYSTEM III microcomputer anti C.C.T.V. camera to convert the analog valued scene into digitized image which could be pro-cessed by a digital computer. Basic software techniques for the computer vision system were aimed at the recognition of 3-dimensional objects. Experiments with these techniques were carried out using the image of a cubicle which could be considered as typical simple 3-dimensional object.

  • PDF

A Study on the Three Dimensional Coordinates Analysis by Direct Linear Transformation (직접선형변환을 이용한 3차원 좌표해석에 관한 연구)

  • 김감래;이호남
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.5 no.2
    • /
    • pp.47-55
    • /
    • 1987
  • In this paper, the direct linear transformation is described in which a inner and exterior orientation parameters are treated as unknown for non-iterative direct space resection, and the computer program was developed to obtain object space coordinates. Image coordinates measurements are conducted with analogue stereo-plotter and digitizer. To prove the appropriateness of the two image coordinate measurement devices and the DLT method, the standard errors of object space coordinates are compared with semi-analytical method.

  • PDF

Measurement and Scale Effects of Digitized Virtual Human Head

  • Takakazu, Ishimatsu;Chan, Tony
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.89.1-89
    • /
    • 2001
  • Measurement of complex surfaces without touching is desirable in several fields. This arises mainly for measurement of complex surfaces including those surfaces that deform during touch. Our research presented in this paper describes the use of a 3D digitizer for scanning 3D objects. The use of such a device, in addition to proper calibration, requires proper scaling in all three dimensions. We propose measurement techniques to measure various aspects of the surface circumference, area and volume. We also present experiments from using a 3D Minolta digitizer for measuring 3D human heads.

  • PDF

Performance Evaluation of Digital Radiography Antiscatter Grids using Film Digitizers

  • Lee, Hyoung-Koo;Lee, Jung-Ae;Kim, Sung-Hyun;Ho, Dong-Su;Kim, Do-Il;Suh, Tae-Suk;Choe, Bo-Young;Kim, Jin-Soo;Kim, Jin-Won
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.393-395
    • /
    • 2002
  • We propose a method which can replace the DR when measuring performance evaluation parameters of antiscatter grids for DR. We used conventional x-ray films to produce grid images, which were scanned by a film digitizer. The digitizer could provide sampling interval of 87 micrometers and pixel depth of 12 bits. Grid line frequencies were measured using aliasing effect and non-uniformities of grids were measured by transforming scanned pixel values of film images into optical densities.

  • PDF

ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY (가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구)

  • Eom Sang-Ho;Oh Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.

A Study on Positive and Negative Visual Stimuli using the Real-Time Human Sensibility Assessment System (실시간 주관적 감성 평가시스템을 이용한 긍정 및 부정 시각자극에 대한 연구)

  • Min, Byeong-Chan;Jeong, Sun-Cheol;Min, Byeong-Un;Sin, Mi-Gyeong;Jeong, Hak-Gi;Kim, Cheol-Jung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.31-43
    • /
    • 2001
  • The present study the feasibility of the new subjective assessment devise; Real-Time Subjective Assessment Digitizer (RTSAD). The subjects were instructed to evaluate their sensibility during the presentation of the positive and the negative visual stimuli using RTSAD. After the presentation of each of the stimulus, a questionnaire was used for comparing the results with those from RTSAD. It was argued that the biggest utility of the RTSAD is the capability of measuring and figuring out the trends of the subjective assessment in real time. The results from the questionnaires unlike the results from RTSAD, reflects only the averaged human sensibility for the entire time of the presentation of the stimulus.

  • PDF