• Title/Summary/Keyword: Digital subtraction image method

Search Result 39, Processing Time 0.034 seconds

Role of Multislice Computerized Tomographic Angiography after Clip Placement in Aneurysm Patients Based on Comparison with Three Dimensional Digital Subtraction Angiography

  • Han, Myung-Hwan;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.103-111
    • /
    • 2007
  • Objective : We evaluated the accuracy of multislice computerized tomographic angiography (MCTA) in the postoperative evaluation of clipped aneurysms by comparising it with three dimensional digital subtraction angiography (3D-DSA). Methods : Between May 2004 and September 2006, we included patients with ruptured cerebral aneurysm of the anterior circulation that was surgically clipped and evaluated by both postoperative MCTA and postoperative 3D-DSA. We measured the diagnostic performance and calculated the sensitivity and specificity of postoperative MCTA compared to 3D-DSA in the detection of aneurysm remnants. Results : A total of 11 neck remnants among the 92 clipped aneurysms (11.9%) were confirmed by 3D-DSA. According to Sindou's classification of aneurysm remnants, 8.7% of clipped aneurysms (8/92) had only neck remnant on 3D-DSA and 3.2% (3/92 aneurysms) had residuum of the neck and sac on 3D-DSA. There were 12 (13.04%) equivocal cases that were difficult to interpret based on the postoperative MCTA. The reasons for the equivocal cases included multiple clips (6 cases, 50.0%). beam-hardening effect (4 cases, 33.3%), motion artifact (1 case, 8.3%), fenestrated clip (1 case, 8.3%) and other combined causes. The sensitivity and specificity of the postoperative MCTA was 81.8% and 88.9%, respectively by ROC curve (p=0.000). Conclusion : MCTA is an accurate noninvasive imaging method used for the assessment of clipped aneurysms in the anterior circulation. If the image quality of postoperative MCTA is good quality and the patient has been treated with a single titanium clip, except a fenestrated clip, the absence of an aneurysm remnant can be diagnosed by MCTA alone and the need for postoperative DSA can be reduced in a large percentage of cases.

An Assessment on effect of Bioabsorbable membrane, allogenic bone and Platelet Rich Plasma in Class II furcation involvement by digital subtraction radiography (2급 치근이개부 치료 시 흡수성 차폐막, 동종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석)

  • Kim, Sang-Hoon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.1
    • /
    • pp.173-186
    • /
    • 2002
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)) in humans by digital subtraction radiography. 12 teeth(control group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)) and bioabsorable membrane(BioMesh(R)), and 12 teeth(test group) were treated with Demineralized Freeze-Dried Bone(Dembone(R)), bioabsorable membrane(BioMesh(R)) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program (5% significance level). The results were as follows: 1. In test group, the radiopacity in 3 months after surgery were significantly increased than 1 month after surgery(p<0.05). However. there were no significant difference between 1 month after surgery and 3 months after surgery in control group(p>0.05). 2. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 1 month after surgery(p<0.05) 3. In test and control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

The Quantitative Analysis by Digital Subtraction Radiography on the Effect of Platelet Rich Plasma Combined with Synthetic Bone Graft on Grade II Furcation Involvement (2급 치근 이개부 치료 시 합성골 이식 및 혈소판 농축 혈장의 골재생 효과에 대한 디지털 공제술의 정량적 분석)

  • Oh, Ji-Soo;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.2
    • /
    • pp.465-475
    • /
    • 2001
  • The purpose of this study was to evaluate effect of platelet rich plasma on the treatment of Grade II furcation involvement, with and without porous resorbable calcium carbonate($Biocoral^{(R)}$)in humans by digital subtraction radiography. 15 teeth(control group) were treated with porous resorbable calcium carbonate($Biocoral^{\(R)}$), and 15 teeth(test group) were treated with porous resorbable calcium carbonate($Biocoral^{(R)}$) and Platelet Rich Plasma. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content by as much as 5%(vol) could be perceived in the subtracted images. The change of mineral content was assessed in the method that two radiographs are put into computer program to be overlapped and the previous image is subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program(5% significance level). The results were as follows: 1. In test group, the radiolucency in 3 months after surgry were significantly increased than 1 month after surgery(p<0.05). 2. In test group, there were no significant difference between 1 month after surgery and 6 months after surgery(p>0.05). 3. In test group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 4. In control group, the radiolucency in 3 months and 6 months after surgery were significantly increased than 1 month after surgery(p<0.05). 5. In control group, the radiopacity in 6 months after surgery were significantly increased than 3 months after surgery(p<0.05). 6. There were no significant difference between test group and control group at 1 month, 3 months after surgery, but radiopacity in test group were significantly increased than control group at 6 months after surgery(p<0.05). In conclusion, Platelet Rich Plasma can enhance bone density.

  • PDF

Automated assessment of cracks on concrete surfaces using adaptive digital image processing

  • Liu, Yufei;Cho, Soojin;Spencer, Billie F. Jr;Fan, Jiansheng
    • Smart Structures and Systems
    • /
    • v.14 no.4
    • /
    • pp.719-741
    • /
    • 2014
  • Monitoring surface cracks is important to ensure the health of concrete structures. However, traditional visual inspection to monitor the concrete cracks has disadvantages such as subjective inspection nature, associated time and cost, and possible danger to inspectors. To alter the visual inspection, a complete procedure for automated crack assessment based on adaptive digital image processing has been proposed in this study. Crack objects are extracted from the images using the subtraction with median filter and the local binarization using the Niblack's method. To adaptively. determine the optimal window sizes for the median filter and the Niblack's method without distortion of crack object an optimal filter size index (OFSI) is proposed. From the extracted crack objects using the optimal size of window, the crack objects are decomposed to the crack skeletons and edges, and the crack width is calculated using 4-connected normal line according to the orientation of the local skeleton line. For an image, a crack width nephogram is obtained to have an intuitive view of the crack distribution. The proposed procedure is verified from a test on a concrete reaction wall with various types of cracks. From the crack images with different crack widths and patterns, the widths of cracks in the order of submillimeters are calculated with high accuracy.

The Application of Unmanned Aerial Photograpy for Effective Monitoring of Marine Debris (해안표착물의 효율적인 모니터링을 위한 무선 조정 항공기 촬영기법의 적용)

  • Jang, Seon-Woong;Lee, Seong-Kyu;Oh, Seung-Yeol;Kim, Dae-Hyun;Yoon, Hong-Joo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.17 no.4
    • /
    • pp.307-314
    • /
    • 2011
  • This study proposed detection method of Marine debris using unmanned aerial photography. For unmanned aerial photography, a RC(Radio Control) helicopter which has good movability and economics was used. To a camera mounting, a gimbal equipment was attached to the bottom of the RC helicopter. The gimbal equipment is very useful because it is not seriously affected by vibration and rolling. In addition, we invented that digital image processing algorithm using Matlab program for detection of marine debris from photographs. Particularly, background subtraction in invented algorithm was applied. As a result, marine debris of a variety of forms from different sand states of coast were reliably detected. In the future, monitoring using proposed method was expected to contribute that the solution to representative problem of monitoring area selecting and estimate the total litter mass over the beach. Moreover, It is considered a greater application possibility to marine environmental observations.

The quantitative analysis by digital subtraction radiography on the effect of Enamel Matrix Protein and Platelet-Rich Plasma, combined with Xenograft in the treatment of intrabony defect in humans (골 내 결손 치료 시 법랑 기질 단백질과 이종골 이식 및 혈소판 농축 혈장의 골 재생 효과에 대한 디지털 공제술의 정량적 분석)

  • Han, Keum-Ah;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.4
    • /
    • pp.961-974
    • /
    • 2005
  • Various biological approaches to the promotion of periodontal regeneration have been used. These can be divided into the use of growth and differentiation factors, application of extracellular matrix proteins and attachment factors and use of mediators of bone metabolism. The purpose of this study was to evaluate the effect of enamel matrix protein and platelet-rich plasma on the treatment of intrabony defect, with bovine-derived bone powder in humans by digital subtraction radiography. 12 teeth(experimental I group) were treated with enamel matrix protein combined with bovine-derived bone powder and 12 teeth(experimental II group) were treated with platelet-rich plasma combined with bovine-derived bone powder. The change of bone density was assessed by digital subtraction radiography in this study. The change of mineral content was assessed in the method that two radiography were put into computer program to be overlapped and the previous image was subtracted by the later one. Both groups were statistically analyzed by Wilcoxon signed Ranks Test and Mann-whitney Test using SPSS program for windows(5% significance level). The results were as follows: 1. The radiolucency in 3 months after surgery was significantly increased than 1 month after surgery in both groups(experimental I and II groups)(p<0.05). 2. The radiopacity in 6 months after surgery was significantly increased than 3 months after surgery in both groups(experimental I and II groups) (p<0.05). 3. In experimental I group, there was no significant difference between 1 month and 6 months after surgery. 4. In experimental II group. the radiopacity in 6 months after surgery was significantly increased than 1 month after surgery(p<0.05). 5. There was no significant difference between experimental I and II group at 1 month and 3 months after surgery, but the radiopacity in experimental II group was significantly increased at 6 months after surgery(p<0.05). In conclusion, platelet-rich plasma can enhance bone density than enamel matrix protein until 6 months after surgery.

Optimal Localization through DSA Distortion Correction for SRS

  • Shin, Dong-Hoon;Suh, Tae-Suk;Huh, Soon-Nyung;Son, Byung-Chul;Lee, Hyung-Koo;Choe, Bo-Young;Shinn, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.39-47
    • /
    • 2000
  • In Stereotactic Radiosurgery (SRS), there are three imaging methods of target localization, such as digital subtraction Angiography (DSA), computed tomography (CT), magnetic resonance imaging (MRI). Especially, DSA and MR images have a distortion effect generated by each modality. In this research, image properties of DSA were studied. A first essential condition in SRS is an accurate information of target locations, since high dose used to treat a patient may give a complication on critical organ and normal tissue. Hut previous localization program did not consider distortion effect which was caused by image intensifier (II) of DSA. A neurosurgeon could not have an accurate information of target locations to operate a patient. In this research, through distortion correction, we tried to calculate accurate target locations. We made a grid phantom to correct distortion, and a target phantom to evaluate localization algorithm. The grid phantom was set on the front of II, and DSA images were obtained. Distortion correction methods consist of two parts: 1. Bilinear transform for geometrical correction and bilinear interpolation for gray level correction. 2. Automatic detection method for calculating locations of grid crosses, fiducial markers, and target balls. Distortion was corrected by applying bilinear transform and bilinear interpolation to anterior-posterior and left-right image, and locations of target and fiducial markers were calculated by the program developed in this study. Localization errors were estimated by comparing target locations calculated in DSA images with absolute locations of target phantom. In the result, the error in average with and without distortion correction is $\pm$0.34 mm and $\pm$0.41 mm respectively. In conclusion, it could be verified that our localization algorithm has an improved accuracy and acceptability to patient treatment.

  • PDF

Feature Extraction System for Land Cover Changes Based on Segmentation

  • Jung, Myung-Hee;Yun, Eui-Jung
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.3
    • /
    • pp.207-214
    • /
    • 2004
  • This study focused on providing a methodology to utilize temporal information obtained from remotely sensed data for monitoring a wide variety of targets on the earth's surface. Generally, a methodology in understanding of global changes is composed of mapping, quantifying, and monitoring changes in the physical characteristics of land cover. The selected processing and analysis technique affects the quality of the obtained information. In this research, feature extraction methodology is proposed based on segmentation. It requires a series of processing of multitempotal images: preprocessing of geometric and radiometric correction, image subtraction/thresholding technique, and segmentation/thresholding. It results in the mapping of the change-detected areas. Here, the appropriate methods are studied for each step and especially, in segmentation process, a method to delineate the exact boundaries of features is investigated in multiresolution framework to reduce computational complexity for multitemporal images of large size.

COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM (직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구)

  • Do Jung-Joo;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

New Carotid Artery Stenosis Measurement Method Using MRA Images (경동맥 MRA 영상을 이용한 새로운 내경 측정 방법)

  • 김도연;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.30 no.12
    • /
    • pp.1247-1254
    • /
    • 2003
  • Currently. the north american symptomatic carotid endarterectomy trial, european carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidate for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiography. rotational angiography, computed tomography angiography and magnetic resonance angiography. A new computerized carotid stenosis measuring system was developed using MR angiography axial image to overcome the drawbacks of conventional carotid stenosis measuring methods, to reduce the variability of inter-observer and intra-observer. The gray-level thresholding is one of the most popular and efficient method for image segmentation. We segmented the carotid artery and lumen from three-dimensional time-of-flight MRA axial image using gray-level thresholding technique. Using the measured intima-media thickness value of common carotid artery for each cases, we separated carotid artery wall from the segmented carotid artery region. After that, the regions of segmented carotid without artery wall were divided into region of blood flow and plaque. The calculation of carotid stenosis degree was performed as the following; carotid stenosis grading is(area measure of plaque/area measure of blood flow region and plaque) * 100%.