A Fundamental Study on the Comparison of As-Planned with As-Built of Free-form Building Skins Using Laser Scanning Technology (Laser Scanning 기술을 이용한 비정형 건축외피의 As-Planned와 As-Built 비교에 관한 기초적 연구)

  • Kwen, Soon-Ho;Shim, Hyoun-Woo;Jang, Hyoun-Seung;Ock, Jong-Ho
    • Korean Journal of Computational Design and Engineering
    • /
    • v.16 no.2
    • /
    • pp.126-136
    • /
    • 2011
  • The existing approaches to freeform building construction cause many problems. However, recent BIM technique development based on parametric modeling method and improvement of freeform materials manufacturing technology using IT technology encouraged many advanced countries to try experimental projects. Thus, laser scanning technique is in the limelight as a new alternative in the field of freeform building construction and inspection. This study selected a domestic small freeform building and practiced laser scanning and as-planned modeling by using Reverse Engineering. Then each deviation was comparatively analyzed through figures which extracted data by numerically analyzing the newly modeled as-built and Excel spread sheet. Through the process, limits and follow-up research subjects are discussed as well.

Current status and future perspectives of CAD/CAM fabricated complete denture (임상가를 위한 특집 2 - CAD/CAM 기술을 이용한 총의치 제작의 현재와 전망)

  • Park, Chan-Jin
    • The Journal of the Korean dental association
    • /
    • v.52 no.6
    • /
    • pp.346-353
    • /
    • 2014
  • Currently, computer-aided technology becomes one of main issues in clinical dentistry. About 25 years ago, the development of dental CAD/CAM systems for the fabrication of crowns and fixed partial dentures leads to be able to fabricate complete denture today. The fabrication of milled complete denture prostheses with digital scanning technology may decrease the number of patient appointments. However, the precise tooth arrangement and evaluation by patient is not promising relatively. The purpose of this review was to analyze the existing literature on computer aided technology for fabricating complete denture with historical background, current status, and future perspectives. In addition, two available commercial systems were introduced.

Optical Reconstruction of Full-color Optical Scanning Holography Images using an Iterative Direct Binary Search Algorithm

  • Lee, Eung Joon;Cho, Kwang Hun;Kim, Kyung Beom;Lim, Seung Ram;Kim, Taegeun;Kang, Ji-Hoon;Ju, Byeong-Kwon;Park, Sang-Ju;Park, Min-Chul;Kim, Dae-Yeon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1845-1848
    • /
    • 2018
  • We introduce a process for optically reconstructing full-color holographic images recorded by optical scanning holography. A complex RGB-color hologram was recorded and converted into a binary hologram using a direct binary search (DBS) algorithm. The generated binary hologram was then optically reconstructed using a spatial light modulator. The discrepancies between the reconstructed object sizes and colors due to chromatic aberration were corrected by adjusting the reconstruction parameters in the DBS algorithm. To the best of our knowledge, this represents the first optical reconstruction of a full-color hologram recorded by optical scanning holography.

Evaluation of validity of polyurethane model fabricated by intra-oral scanning method (구강 내 스캐닝 방법에 의해 제작된 폴리우레탄 모형의 정확도 평가)

  • Kim, Won-Tae;Lee, Byung-Ki;Hyun, Joung-Ku;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.91-96
    • /
    • 2014
  • Purpose: The purpose of this study was evaluate the validity of polyurethane model fabricated by intra oral scanning method. Methods: Ten sam cases of stone models were manufactured from master model, and polyurethane models were made with the intra oral scanning and CNC milling method. One examiner individually measured 6 distances(intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) on the stone models and the polyurethane models. The Mann-Whitney U test(${\alpha}$=0.05) were used for statistical analysis. Results: The mean difference between measurements made directly on the stone models and those made on the polyurethane models was 0.31-0.38mm. No statistically differences between the two groups were founded 4 distances(p>0.05), but 2 distances were statistically significant(p<0.05). Conclusion: Stone models showed larger than polyurethane models fabricated by intra oral scanning method.

A Study on the 3D Digital Restoration Technology Using a Shard of a Joseon Dynasty White Porcelain Water Dropper (조선시대 백자 연적 편(片)을 활용한 3차원 디지털 복원 기술 연구)

  • Shin, Woocheol;Kim, Kyungjoong;Wi, Koangchul
    • Conservation Science in Museum
    • /
    • v.22
    • /
    • pp.85-96
    • /
    • 2019
  • The restoration of ceramics excavated in fragments is limited by the difficulty of inferring the overall shape of the original object. However, recent innovations in digital technology can help to overcome the limits of conventional restoration using handwork. This study explored the potential of digital technology by digitally restoring a shard from a white porcelain water dropper excavated at a kiln site at Sindae-ri. In order to complete the digital restoration, 3D scanning was applied to obtain scan data, and 3D modeling and texture mapping were performed. In this way, three-dimensional data with patterns and color information was acquired and the original form of the water dropper could be ascertained based on the shard. The study found that the data acquired from digital restoration can be used for various purposes, including for obtaining data on cross-sections or missing portions of a relic.

Remote sensing and photogrammetry techniques in diagnostics of concrete structures

  • Janowski, Artur;Nagrodzka-Godycka, Krystyna;Szulwic, Jakub;Ziolkowski, Patryk
    • Computers and Concrete
    • /
    • v.18 no.3
    • /
    • pp.405-420
    • /
    • 2016
  • Recently laser scanning technologies become widely used in many areas of the modern economy. In the following paper authors show a potential spectrum of use Terrestrial Laser Scanning (TLS) in diagnostics of reinforced concrete elements. Based on modes of failure analysis of reinforcement concrete beam authors describe downsides and advantages of adaptation of terrestrial laser scanning to this purpose, moreover reveal under which condition this technology might be used. Research studies were conducted by Faculty of Civil and Environmental Engineering at Gdansk University of Technology. An experiment involved bending of reinforced concrete beam, the process was registered by the terrestrial laser scanner. Reinforced concrete beam was deliberately overloaded and eventually failed by shear. Whole failure process was tracing and recording by scanner Leica ScanStation C10 and verified by synchronous photographic registration supported by digital photogrammetry methods. Obtained data were post-processed in Leica Cyclone (dedicated software) and MeshLab (program on GPL license). The main goal of this paper is to prove the effectiveness of TLS in diagnostics of reinforced concrete elements. Authors propose few methods and procedures to virtually reconstruct failure process, measure geometry and assess a condition of structure.

Gas Typed Digital X-ray Image Sensor Using PDP Fabrication Process (PDP공정을 이용한 가스 방식의 디지털 X-ray 영상 센서)

  • Kim, Chang Man;Kim, Si Hyung;Nam, Ki Chang;Kim, Sang Hee;Song, Kwang Soup
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.322-327
    • /
    • 2012
  • Parallel-plate-type scanning sensors have been commercially used for X-ray imaging sensors. In this study, we manufactured the scan typed 1D X-ray image sensor that can be used to obtain scanning images, by using the plasma display panel (PDP) fabrication process. We fabricated drift and pixel electrodes in the glass chamber and injected Xe gas at atmospheric pressure. We evaluated the intensity of a pixel signal depending on the bias voltage on the drift electrode and investigated the characteristics of shielding effect on the single pixel using lead (Pb). The adsorption rate of X-ray photon is low (4%) on the soda lime glass (1.1mm) and the electrical signal detected on the X-ray sensor was increased in the high bias voltage. We acquired digital X-ray scanning image with our DAS (data acquisition system) and sensor scanning system.

A Study on the Extraction of Horizontal Alignment and Cross-Section of Roads using Mobile Laser Scanning Data (모바일 레이저 스캐닝 데이터를 이용한 도로선형 및 횡단면 추출에 관한 연구)

  • Kim, Se-Geun;Lee, Hyun-Yong;Joo, Young-Eun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.3
    • /
    • pp.207-218
    • /
    • 2006
  • The extraction of horizontal alignment and cross-section of roads is very important task in road safety diagnosis. Existing road safety diagnosis methods by investigators need much time and expense but don't provide various data. Therefor, we need road shape classification automatically and extraction method of horizontal alignment and cross-section of roads through digital photogrammetry system using GPS-VAN with laser scanner. In this paper, we propose a method of mobile laser scanning data acquisition, processing and developing extraction methods of horizontal alignment and cross-section of roads using mobile laser scanning data by GPS-VAN.

  • PDF

Development of Dark Field image Processing Technique for the Investigation of Nanostructures

  • Jeon, Jongchul;Kim, Kyou-Hyun
    • Journal of Powder Materials
    • /
    • v.24 no.4
    • /
    • pp.285-291
    • /
    • 2017
  • We propose a custom analysis technique for the dark field (DF) image based on transmission electron microscopy (TEM). The custom analysis technique is developed based on the $DigitalMicrograph^{(R)}$ (DM) script language embedded in the Gatan digital microscopy software, which is used as the operational software for most TEM instruments. The developed software automatically scans an electron beam across a TEM sample and records a series of electron diffraction patterns. The recorded electron diffraction patterns provide DF and ADF images based on digital image processing. An experimental electron diffraction pattern is recorded from a IrMn polycrystal consisting of fine nanograins in order to test the proposed software. We demonstrate that the developed image processing technique well resolves nanograins of ~ 5 nm in diameter.

A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction

  • Anh, Ji-won;Park, Ji-Man;Chun, Youn-Sic;Kim, Miae;Kim, Minji
    • The korean journal of orthodontics
    • /
    • v.46 no.1
    • /
    • pp.3-12
    • /
    • 2016
  • Objective: The purpose of this study was to compare the precision of three-dimensional (3D) images acquired using iTero$^{(R)}$(Align Technology Inc., San Jose, CA, USA) and Trios$^{(R)}$(3Shape Dental Systems, Copenhagen, Denmark) digital intraoral scanners, and to evaluate the effects of the severity of tooth irregularities and scanning sequence on precision. Methods: Dental arch models were fabricated with differing degrees of tooth irregularity and divided into 2 groups based on scanning sequence. To assess their precision, images were superimposed and an optimized superimposition algorithm was employed to measure any 3D deviation. The t-test, paired t-test, and one-way ANOVA were performed (p < 0.05) for statistical analysis. Results: The iTero$^{(R)}$ and Trios$^{(R)}$ systems showed no statistically significant difference in precision among models with differing degrees of tooth irregularity. However, there were statistically significant differences in the precision of the 2 scanners when the starting points of scanning were different. The iTero$^{(R)}$ scanner (mean deviation, $29.84{\pm}12.08{\mu}m$) proved to be less precise than the Trios$^{(R)}$ scanner ($22.17{\pm}4.47{\mu}m$). Conclusions: The precision of 3D images differed according to the degree of tooth irregularity, scanning sequence, and scanner type. However, from a clinical standpoint, both scanners were highly accurate regardless of the degree of tooth irregularity.