• Title/Summary/Keyword: Digital radiograph system

Search Result 24, Processing Time 0.02 seconds

A study on Equalization of X-Ray Chest Radiograph using Artificial Neural Networks (인공신경망을 이용한 X-선 흥부영상 등화)

  • 이주원;이한욱;이종회;신태민;김영일;이건기
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1059-1062
    • /
    • 1999
  • Recently, X-ray chest radiograph is showing a tendency to take an image of digital radiograph so as to diagnose the pathological pattern of chest in a usual. When the radiologist observes the chest image derived from digital radiograph system on the monitor. he feels difficult to find out because of the sensitivity of chest radiograph. It takes amount of time to adjust the proper image for diagnosis. Therefore, we provided the result and the method of the optimal image equalization for image enhancement.

  • PDF

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

A Study on the Diagnostic Detection Ability of the Artificial Proximal Caries by Digora$\textregistered$ (Digora$\textregistered$ 영상시스템을 이용한 인접면 인공 치아우식병소의 진단능에 관한 연구)

  • Oh Kyung-Ran;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.415-433
    • /
    • 1998
  • Digora system is an intraoral indirect digital radiography system utilizing storage phosphor image plate. It has wide dynamic range which allows it to decrease the patient s exposure time and may increase diagnostic ability through image processing (such as edge enhancement, grey scale conversion, brightness change, and contrast enhancement). And also, it can transmit and storage image information. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries between Conventional radiograph and Digora images(unenhanced image, brightness & contrast controlled image, and edge enhanced image). ROC(Receiver Operating Characteristic) analysis, paired t-tests, and F-tests were done for the statistical evaluation of detectability. The following results were acquired: 1. In Grade I lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.953, 0.933, 0.965, 0.978 (p>0.05). 2. In Grade II lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.969, 0.964, 0.988, 0.994. Among theses areas, there was just statistical significance between Diagnostic abilities of Digora edge enhanced image and Conventional radiograph (p<0.05). 3. In the Interobserver variability, the ROC curve areas of Digora edge enhanced image was lowermost in these areas, regardless of the Carious lesion depths. In conclusion, intraoral indirect digital system, Digora system, has the potential possibility as an alternative of Conventional radiograph in the diagnosis of proximal caries.

  • PDF

A study on the geometric correction for the digital subtraction radiograph (디지털 공제방사선영상의 기하학적 보정에 관한 연구)

  • Lim Suk-Young;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.23-34
    • /
    • 2001
  • Purpose : To develop a new subtraction program for registering digital periapical images based on the correspondence of anatomic structures. Materials and Methods: The digital periapical images were obtained by Digora system with Rinn XCP equipment after translation of 1-16 mm, and rotation of 2-20° at the premolar and molar areas of the human dried mandible. The new subtraction program, NIH Image program and Emago/Advanced program were compared by the peak-signal-to noise ratio (PSNR). Results : The new subtraction program was superior to NIH Images program and Emagol Advanced program up to 16 mm translation and horizontal angulation up to 4°. Conclusion: The new subtraction program can be used for subtracting digital periapical images.

  • PDF

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

QUANTITATIVE ANALYSIS OF THE ALVEOLAR BONE CHANGE BY THE DIGITAL SUBTRACTION RADIOGRAPHY (Digital subtraction radiography를 이용한 치조골 변화의 정략적 분석)

  • Ryue, Myung-Girl;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.67-75
    • /
    • 1995
  • The progress of periodontal disease and the wound healing process after treatment result in alveolar bone bone change. So, detection of it is very important in the diagnosis and the radiograph of periodontal disease. Various effects have been made to assess the subtle alveolar bone change and digital subtraction radiography (DSR) has been reported to be the best method in evaluating it qualitatively and quantitatively. The present study was performed to estimate the detectable alveolar bone change qualitatively with digital subtraction radiography. For the in vitro study, 10 intraoral standard radiographs were taken from porcine dry mandible which a rectangular cortical bone chip of 0.1mm to 1.0mm thickness with 0.1mm increment was attached on the buccal surface. The radiographs without and with bone plates were reviewed at the same time by 10 observers and requested to detect the presence of cortical bone plates. Digital Subtraction radiograph was reviewed subsequently by using the DSR system(digital converter-256 grey-levels,DT 2851,Data Translation Co., U.S.A;IBM 386 ; CCD camera, FOTOVIX, Tamrom Co., Japan). The detectable thickness of cortical bone plate was O.4mm on the intraoral radiograph and 0.2mm on the subtaction images. For the human study, radiographs were taken from patients by using intraoral film holding device and aluminum reference wedge before and 3 month after bone graft and 1 week after osteoplasty. The grey level change was estimated in the subtraction images and calculated to aluminum equivalent thickness. The grey level of the grafted site was higher that that of healthy controls. Average grey levels of change on healthy controls were O.48mm aluminum equivalent. However, the amount of changes in grafted sites were 1.87mm aluminum thickness equivalent and in the site of osteoplasty were -1.49mm aluminum thickness equivalent. In conclusion, digital subtraction radiography was more effective in detecting as subtle change of alveolar bone than intraoral standard radiography. With the aid of quantitative analysis of digital subtraction radiography, alveolar bone resorption of apposition can be estimated during diagnosis and treatment of periodontally diseased patients.

  • PDF

Radiograph-based Diagnostic Methods for Thoracic and Lumbar Spine Malposition in Chuna Manual Therapy Using Biomarkers (단순 방사선 영상기반 바이오마커를 활용한 흉·요추의 추나의학적 변위 진단 방법)

  • Jin-Hyun Lee;Minho Choi;Joong Il Kim;Jun-Su Jang;Tae-Yong Park
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2023
  • Objectives This study aimed to propose biomarkers for diagnosing Chuna manual therapy (CMT) based on X-ray images in the thoracic and lumbar spines. Methods Through a literature review and expert consensus process, diagnostic biomarkers for CMT were selected based on the listing system in thoracic and lumbar radiograph anterior-posterior (AP) and lateral views. Results 1. Diagnostic biomarkers were derived from four points on the outer contour of the vertebral body in the thoracic and lumbar spine radiograph lateral view, enabling the diagnosis of flexion and extension malposition. 2. Additional diagnostic biomarkers were identified in the thoracic and lumbar radiographAP view, utilizing points on the outer contour of the vertebral body. These biomarkers facilitate the diagnosis of lateral bending. Moreover, biomarkers derived from the innermost point of the pedicle contour allow for the diagnosis of rotation malposition. 3. Furthermore, through the biomarkers proposed in this study, all malpositions of the thoracolumbar spines and complex Type I and II malpositions can be diagnosed in CMT. Conclusions The biomarkers reported in this study consist of minimal points to determine the position of the vertebral body, providing the advantage of simplicity while minimizing potential errors during the CMT diagnostic process. Further clinical research and the development of related programs should be pursued to expand the evidence for CMT.

Digital X-ray Imaging in Dentistry (치과에서 디지털 x-선 영상의 이용)

  • Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF

Image Enhancement and Clinical Evaluation in Digital Chest Radiography (디지털 방사선 흉부영상의 영상개선과 임상평가)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.143-149
    • /
    • 2008
  • The aim of this study is to suggest the method for image enhancement of digital chest radiograph and evaluate clinically the quality of the resultant image. A nonlinear iterative filter was developed in order to reduce quantum noise preserving edge. Dynamic range was adjusted and adaptive image enhancement was performed based on the property of anatomic region and the degree of compatibility with neighboring pixels. The lung fields were enhanced appropriately to visualize effectively vascular tissue, bronchus and lung tissue with the desired mediastinum enhancement. Clinic evaluation was performed by three radiologists with at least 8 years experience. The anatomic regions of 11 in PA and 9 in Lateral were observed carefully in each 100 radiographs according to ITU (International Telecommunication Union) recommendation 500 protocol. The result showed the mean 3.4 between good and adequate. This means that the clinical utility of the image quality is enough. In this study, image enhancement was carried out considering image display device and human perceptual system to prevent the loss of useful anatomic information. In order to increase the diagnostic accuracy in digital radiograph, the continuous study on image enhancement is needed.

  • PDF