• Title/Summary/Keyword: Digital radiograph

Search Result 65, Processing Time 0.028 seconds

A study on Equalization of X-Ray Chest Radiograph using Artificial Neural Networks (인공신경망을 이용한 X-선 흥부영상 등화)

  • 이주원;이한욱;이종회;신태민;김영일;이건기
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.1059-1062
    • /
    • 1999
  • Recently, X-ray chest radiograph is showing a tendency to take an image of digital radiograph so as to diagnose the pathological pattern of chest in a usual. When the radiologist observes the chest image derived from digital radiograph system on the monitor. he feels difficult to find out because of the sensitivity of chest radiograph. It takes amount of time to adjust the proper image for diagnosis. Therefore, we provided the result and the method of the optimal image equalization for image enhancement.

  • PDF

Digital contrast subtraction radiography for proximal caries diagnosis (인접면 치아우식 진단을 위한 디지털 방사선 조영 공제술)

  • Kang Byung-Cheol;Yoon Suk-Ja
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.123-127
    • /
    • 2002
  • Purpose : To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Materials and Methods: Thirty-six teeth with 57 proximal surfaces were radiographied using a size #2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. Results: The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. Conclusion: The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  • PDF

Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position (디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과)

  • Kim, Mi-Ja;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-SUk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

A STUDY ON THE READABILITY OF PERIAPICAL RADIOGRAPH WITH THE DIGITAL RADIOGRAPHY (Digital radiography를 이용한 치근단 X선 사진의 판독능에 관한 실험적 연구)

  • Lee Kon;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.117-127
    • /
    • 1992
  • This investigation was performed to test the readability of the video based digital radiography, that can be applied clinically, compared with the periapical radiograph. The experiments were performed with IBM-PC/AT compatible, video camera and ADC (analog-digital converter). And spatial resolution was 512 X 480 with 256 (8 bit) gray levels. The radiographs obtained by using variable steps of exposure time were digitized. and then the digital images were analyzed. The obtained results were as follows: 1. There was no remarkable difference in readability between the radiographs and their digital images. However, under over exposure the digital images were superior to the radiographs in readability and vice versa. 2. As the exposure time was increased, the gray level of the digital image was decreased proportionally. 3. The correlation beween the regions of interest and the aluminum step wedges were relatively close; R=0.9965 (p <0.001).

  • PDF

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

Convergence and integration study related to development of digital contents for radiography training using dental radiograph and augmented reality (치과방사선사진과 증강현실을 활용한 방사선촬영법 숙련용 디지털 콘텐츠 개발에 대한 융복합 연구)

  • Gu, Ja-Young;Lee, Jae-Gi
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.441-447
    • /
    • 2018
  • This study aims to develop digital techniques that enable repeated practice of dental radiography using augmented reality technology. A three-dimensional object was fabricated by superimposing a photograph of an adult model and a computed tomography image of a manikin phantom. The system was structured using 106 radiographs such that one of these saved radiographs is opened when the user attempts to take a radiograph on a mobile device. This system enabled users to repeatedly practice at the pre-clinical stage without exposure to radiation. We attempt to contribute to enhancing dental hygienists' competency in dental radiography using these techniques. However, a system that enables the user to actually take a radiograph based on face recognition would be more useful in terms of practice, so additional studies are needed on the topic.

QUANTITATIVE ANALYSIS OF THE ALVEOLAR BONE CHANGE BY THE DIGITAL SUBTRACTION RADIOGRAPHY (Digital subtraction radiography를 이용한 치조골 변화의 정략적 분석)

  • Ryue, Myung-Girl;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.1
    • /
    • pp.67-75
    • /
    • 1995
  • The progress of periodontal disease and the wound healing process after treatment result in alveolar bone bone change. So, detection of it is very important in the diagnosis and the radiograph of periodontal disease. Various effects have been made to assess the subtle alveolar bone change and digital subtraction radiography (DSR) has been reported to be the best method in evaluating it qualitatively and quantitatively. The present study was performed to estimate the detectable alveolar bone change qualitatively with digital subtraction radiography. For the in vitro study, 10 intraoral standard radiographs were taken from porcine dry mandible which a rectangular cortical bone chip of 0.1mm to 1.0mm thickness with 0.1mm increment was attached on the buccal surface. The radiographs without and with bone plates were reviewed at the same time by 10 observers and requested to detect the presence of cortical bone plates. Digital Subtraction radiograph was reviewed subsequently by using the DSR system(digital converter-256 grey-levels,DT 2851,Data Translation Co., U.S.A;IBM 386 ; CCD camera, FOTOVIX, Tamrom Co., Japan). The detectable thickness of cortical bone plate was O.4mm on the intraoral radiograph and 0.2mm on the subtaction images. For the human study, radiographs were taken from patients by using intraoral film holding device and aluminum reference wedge before and 3 month after bone graft and 1 week after osteoplasty. The grey level change was estimated in the subtraction images and calculated to aluminum equivalent thickness. The grey level of the grafted site was higher that that of healthy controls. Average grey levels of change on healthy controls were O.48mm aluminum equivalent. However, the amount of changes in grafted sites were 1.87mm aluminum thickness equivalent and in the site of osteoplasty were -1.49mm aluminum thickness equivalent. In conclusion, digital subtraction radiography was more effective in detecting as subtle change of alveolar bone than intraoral standard radiography. With the aid of quantitative analysis of digital subtraction radiography, alveolar bone resorption of apposition can be estimated during diagnosis and treatment of periodontally diseased patients.

  • PDF

A study on the geometric correction for the digital subtraction radiograph (디지털 공제방사선영상의 기하학적 보정에 관한 연구)

  • Lim Suk-Young;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.23-34
    • /
    • 2001
  • Purpose : To develop a new subtraction program for registering digital periapical images based on the correspondence of anatomic structures. Materials and Methods: The digital periapical images were obtained by Digora system with Rinn XCP equipment after translation of 1-16 mm, and rotation of 2-20° at the premolar and molar areas of the human dried mandible. The new subtraction program, NIH Image program and Emago/Advanced program were compared by the peak-signal-to noise ratio (PSNR). Results : The new subtraction program was superior to NIH Images program and Emagol Advanced program up to 16 mm translation and horizontal angulation up to 4°. Conclusion: The new subtraction program can be used for subtracting digital periapical images.

  • PDF

Radiograph-based Diagnostic Methods for Thoracic and Lumbar Spine Malposition in Chuna Manual Therapy Using Biomarkers (단순 방사선 영상기반 바이오마커를 활용한 흉·요추의 추나의학적 변위 진단 방법)

  • Jin-Hyun Lee;Minho Choi;Joong Il Kim;Jun-Su Jang;Tae-Yong Park
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2023
  • Objectives This study aimed to propose biomarkers for diagnosing Chuna manual therapy (CMT) based on X-ray images in the thoracic and lumbar spines. Methods Through a literature review and expert consensus process, diagnostic biomarkers for CMT were selected based on the listing system in thoracic and lumbar radiograph anterior-posterior (AP) and lateral views. Results 1. Diagnostic biomarkers were derived from four points on the outer contour of the vertebral body in the thoracic and lumbar spine radiograph lateral view, enabling the diagnosis of flexion and extension malposition. 2. Additional diagnostic biomarkers were identified in the thoracic and lumbar radiographAP view, utilizing points on the outer contour of the vertebral body. These biomarkers facilitate the diagnosis of lateral bending. Moreover, biomarkers derived from the innermost point of the pedicle contour allow for the diagnosis of rotation malposition. 3. Furthermore, through the biomarkers proposed in this study, all malpositions of the thoracolumbar spines and complex Type I and II malpositions can be diagnosed in CMT. Conclusions The biomarkers reported in this study consist of minimal points to determine the position of the vertebral body, providing the advantage of simplicity while minimizing potential errors during the CMT diagnostic process. Further clinical research and the development of related programs should be pursued to expand the evidence for CMT.

A Study on the Diagnostic Detection Ability of the Artificial Proximal Caries by Digora$\textregistered$ (Digora$\textregistered$ 영상시스템을 이용한 인접면 인공 치아우식병소의 진단능에 관한 연구)

  • Oh Kyung-Ran;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.415-433
    • /
    • 1998
  • Digora system is an intraoral indirect digital radiography system utilizing storage phosphor image plate. It has wide dynamic range which allows it to decrease the patient s exposure time and may increase diagnostic ability through image processing (such as edge enhancement, grey scale conversion, brightness change, and contrast enhancement). And also, it can transmit and storage image information. The purpose of this study was to evaluate the diagnostic ability of artificial proximal caries between Conventional radiograph and Digora images(unenhanced image, brightness & contrast controlled image, and edge enhanced image). ROC(Receiver Operating Characteristic) analysis, paired t-tests, and F-tests were done for the statistical evaluation of detectability. The following results were acquired: 1. In Grade I lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.953, 0.933, 0.965, 0.978 (p>0.05). 2. In Grade II lesions, the mean ROC areas of Conventional radiograph, Digora unenhanced image, Digora controlled image, and Digora edge enhanced image were 0.969, 0.964, 0.988, 0.994. Among theses areas, there was just statistical significance between Diagnostic abilities of Digora edge enhanced image and Conventional radiograph (p<0.05). 3. In the Interobserver variability, the ROC curve areas of Digora edge enhanced image was lowermost in these areas, regardless of the Carious lesion depths. In conclusion, intraoral indirect digital system, Digora system, has the potential possibility as an alternative of Conventional radiograph in the diagnosis of proximal caries.

  • PDF