• Title/Summary/Keyword: Digital radiation

Search Result 571, Processing Time 0.024 seconds

Analysis of Land Surface Temperature from MODIS and Landsat Satellites using by AWS Temperature in Capital Area (수도권 AWS 기온을 이용한 MODIS, Landsat 위성의 지표면 온도 분석)

  • Jee, Joon-Bum;Lee, Kyu-Tae;Choi, Young-Jean
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.2
    • /
    • pp.315-329
    • /
    • 2014
  • In order to analyze the Land Surface Temperature (LST) in metropolitan area including Seoul, Landsat and MODIS land surface temperature, Automatic Weather Station (AWS) temperature, digital elevation model and landuse are used. Analysis method among the Landsat and MODIS LST and AWS temperature is basic statistics using by correlation coefficient, root-mean-square error and linear regression etc. Statistics of Landsat and MODIS LST are a correlation coefficient of 0.32 and Root Mean Squared Error (RMSE) of 4.61 K, respectively. And statistics of Landsat and MODIS LST and AWS temperature have the correlations of 0.83 and 0.96 and the RMSE of 3.28 K and 2.25 K, respectively. Landsat and MODIS LST have relatively high correlation with AWS temperature, and the slope of the linear regression function have 0.45 (Landsat) and 1.02 (MODIS), respectively. Especially, Landsat 5 has lower correlation about 0.5 or less in entire station, but Landsat 8 have a higher correlation of 0.5 or more despite of lower match point than other satellites. Landsat 7 have highly correlation of more than 0.8 in the center of Seoul. Correlation between satellite LSTs and AWS temperature with landuse (urban and rural) have 0.8 or higher. Landsat LST have correlation of 0.84 and RMSE of more than 3.1 K, while MODIS LST have correlation of more than 0.96 and RMSE of 2.6 K. Consequently, the difference between the LSTs by two satellites have due to the difference in the optical observation and detection the radiation generated by the difference in the area resolution.

Evaluations of the Space Dose and Dose Reductions in Patients and Practitioners by Using the C-arm X-ray Tube Shielding Devices Developed in Our Laboratory

  • Kim, Jae Seok;Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Jung, Hai Jo;Hoe, Seong Wook;Son, Jin Hyun;Kang, Byeong Sam
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • The present study used a digital angiography x-ray device to measure the space dose and exposure dose of patients and practitioners using x-ray tube shielding devices developed in our laboratory. The intent of the study was to reduce the space dose within the test room, and to reduce the exposure dose of patients and practitioners. The patient and practitioner exposure doses were measured in five configurations in a human body model. The glass dosimeter was placed on the eye lenses, thyroid glands, left shoulder, right shoulder, and gonads. The beam was collimated at full size and at a 48% reduction for a comparative analysis of the measurements. The space dose was measured with an ion chamber at distances of 50 cm, 100 cm, and 150 cm from the x-ray tube under the following conditions: no shielding device; a shielding device made of 3-mm-thick lead (Pb) [Pb 3 mm shield], and a shielding device made of 3-mm-thick Pb (outside) and 3-mm-thick aluminum (Al) (inside) [Pb 3 mm+Al 3 mm shield]. The absorbed dose was the lowest when the 3-mm-thick Pb+3-mm-thick Al shield was used. For measurements made with collimated beams with a 48% reduction, the dose was the lowest at $154{\mu}Gy$ when the 3-mm-thick Pb+3-mm-thick Al shield was used, and was $9{\mu}Gy$ lower than the measurements made with no shielding device. If the space dose can be reduced by 20% in all situations where the C-arm is employed by using the x-ray tube shielding devices developed in our laboratory, this is expected to play an important role in reducing the annual exposure dose for patients, practitioners, and assistants.

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.

Efficient Data Acquisition Technique for Clinical Application of Multileaf Collimator (다엽콜리메이터의 임상적용을 위한 효율적인 정보 취득 기술)

  • Lee, Jae-Seung;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.182-188
    • /
    • 2008
  • The MLC(multi leaf collimator) in charge of important role in radiation therapy field recently have been exchanging from shielding block into it rapidly, owing to being convenient. However, MLC can be occurred the leakage dose of inter_leaves and the error of algorithm in imput and output from digital signal. We compared the difference of imput method to MLC made by Varian Cop. with the error and effective field induced by MLC shaper and film scanner based on XimaVision value as using MLC layer of various shapes. According to comparing standard value with them to basic MLC layer (test1-5), MLC shaper was $0{\sim}0.29cm$, $0.23{\sim}3.59cm^2$ and film scanner was $0{\sim}0.78cm$, $0.24{\sim}3.89cm^2$. At the MLC layer to be applied in clinic, MLC shaper was $0{\sim}0.54cm$, $0.04{\sim}1.68cm^2$ and film scanner was $0{\sim}0.78cm$, $0.24{\sim}3.89cm^2$. The more distance and field from axis of central line increase, the more bigger the error value increases. There is a few mm error from standard point at the process which imput various information to apply MLC in clinic. and effective field did not have variation of monitor unit and dose owing to being a few cm2 error against real field. But there are some problem to shield critical organs because some part of target volume induced by the movement of organs can be not included, therefore we have to pay attention on the process to imput MLC layer

Sensitivity Analysis of the High-Resolution WISE-WRF Model with the Use of Surface Roughness Length in Seoul Metropolitan Areas (서울지역의 고해상도 WISE-WRF 모델의 지표면 거칠기 길이 개선에 따른 민감도 분석)

  • Jee, Joon-Bum;Jang, Min;Yi, Chaeyeon;Zo, Il-Sung;Kim, Bu-Yo;Park, Moon-Soo;Choi, Young-Jean
    • Atmosphere
    • /
    • v.26 no.1
    • /
    • pp.111-126
    • /
    • 2016
  • In the numerical weather model, surface properties can be defined by various parameters such as terrain height, landuse, surface albedo, soil moisture, surface emissivity, roughness length and so on. And these parameters need to be improved in the Seoul metropolitan area that established high-rise and complex buildings by urbanization at a recent time. The surface roughness length map is developed from digital elevation model (DEM) and it is implemented to the high-resolution numerical weather (WISE-WRF) model. Simulated results from WISE-WRF model are analyzed the relationship between meteorological variables to changes in the surface roughness length. Friction speed and wind speed are improved with various surface roughness in urban, these variables affected to temperature and relative humidity and hence the surface roughness length will affect to the precipitation and Planetary Boundary Layer (PBL) height. When surface variables by the WISE-WRF model are validated with Automatic Weather System (AWS) observations, NEW experiment is able to simulate more accurate than ORG experiment in temperature and wind speed. Especially, wind speed is overestimated over $2.5m\;s^{-1}$ on some AWS stations in Seoul and surrounding area but it improved with positive correlation and Root Mean Square Error (RMSE) below $2.5m\;s^{-1}$ in whole area. There are close relationship between surface roughness length and wind speed, and the change of surface variables lead to the change of location and duration of precipitation. As a result, the accuracy of WISE-WRF model is improved with the new surface roughness length retrieved from DEM, and its surface roughness length is important role in the high-resolution WISE-WRF model. By the way, the result in this study need various validation from retrieved the surface roughness length to numerical weather model simulations with observation data.

A Study on Technique for Image Quality Enhancement to Maximize Container Inspection Efficiency (컨테이너 검사 효율 극대화를 위한 화질 향상 기법 연구)

  • Lee, Chang-Ho;Shin, Ji-Hye;Kim, Jang-Oh;Jung, Young-Jin;Min, Byung-In
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.639-646
    • /
    • 2017
  • The purpose of this study is to present the algorithm to minimize the image noise caused by deterioration of high X-ray container inspection equipment and the faulty detection sensors, and to improvement quality of the container inspection images using MATLAB Toolbox. The daily checking images for the container inspection were used with the subject images and the noise caused by the horizontal and vertical images was evaluated with Root Mean Square (RMS) method, which is the most basic evaluation method of digital radiation image. Also, quality of the improved images was evaluated compared to quality of the orignal images. As a result, all RMS value of the improved images was lower then the original images by a mean of 13.5% in the horizontal images and 18.2% in the vertical images respectively. Also so did RMS value of the improved container images, by a mean of 13.4% in the horizontal images and 19.1% in the vertical images respectively. These findings can be verified objectively and visually and they would help the reading process of the container images be effective in Korea Customs Service.

Characteristics of Remote Sensors on KOMPSAT-I (다목적 실용위성 1호 탑재 센서의 특성)

  • 조영민;백홍렬
    • Korean Journal of Remote Sensing
    • /
    • v.12 no.1
    • /
    • pp.1-16
    • /
    • 1996
  • Korea Aerospace Research Institute(KARI) is developing a Korea Multi-Purpose Satellite I(KOMPSAT-I) which accommodates Electro-Optical Camera(EOC), Ocean Color Imager(OCI), Space Physics Sensor(SPS) for cartography, ocean color monitoring, and space environment monitoring respectively. The satellite has the weight of about 500 kg and is operated on the sun synchronized orbit with the altitude of 685km, the orbit period of 98 minutes, and the orbit revisit time of 28days. The satellite will be launched in the third quarter of 1999 and its lifetime is more than 3 years. EOC has cartography mission to provide images for the production of scale maps, including digital elevation models, of Korea from a remote earth view in the KOMPSAT orbit. EOC collects panchromatic imagery with the ground sample distance(GSD) of 6.6m and the swath width of 15km at nadir through the visible spectral band of 510-730 nm. EOC scans the ground track of 800km per orbit by push-broom and body pointed method. OCI mission is worldwide ocean color monitoring for the study of biological oceanography. OCI is a multispectral imager generating 6 color ocean images with and <1km GSD by whisk-broom scanning method. OCI is designed to provide on-orbit spectral band selectability in the spectral range from 400nm to 900nm. The color images are collected through 6 primary spectral bands centered at 443, 490, 510, 555, 670, 865nm or 6 spectral bands selected in the spectral range via ground commands after launch. SPS consists of High Energy Particle Detector(HEPD) and Ionosphere Measurement Sensor(IMS). HEPD has mission to characterize the low altitude high energy particle environment and to study the effects of radiation environment on microelectronics. IMS measures densities and temperature of electrons in the ionosphere and monitors the ionospheric irregularities in KOMPSAT orbit.

The Study on the Reduction of Patient Surface Dose Through the use of Copper Filter in a Digital Chest Radiography (디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구)

  • Shin, Soo-In;Kim, Chong-Yeal;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.223-228
    • /
    • 2008
  • The most critical point in the medical use of radiation is to minimize the patient's entrance dose while maintaining the diagnostic function. Low-energy photons (long wave X-ray) among diagnostic X-rays are unnecessary because they are mostly absorbed and contribute the increase of patient's entrance dose. The most effective method to eliminate the low-energy photons is to use the filtering plate. The experiments were performed by observing the image quality. The skin entrance dose was 0.3 mmCu (copper) filter. A total of 80 images were prepared as two sets of 40 cuts. In the first set (of 40 cuts), 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of signal + noise image set. In the second set of 40 cuts, 20 cuts were prepared for the non-filter set and another 20 cuts for the Cu filter of non-signal image (noisy image) with random location of diameter 4 mm and 3 mm thickness of acryl disc for ROC signal at the chest phantom. P(S/s) and P(S/n) were calculated and the ROC curve was described in terms of sensitivity and specificity. Accuracy were evaluated after reading by five radiologists. The number of optically observable lesions was counted through ANSI chest phantom and contrast-detail phantom by recommendation of AAPM when non-filter or Cu filter was used, and the skin entrance dose was also measured for both conditions. As the result of the study, when the Cu filter was applied, favorable outcomes were observed on, the ROC Curve was located on the upper left area, sensitivity, accuracy and the number of CD phantom lesions were reasonable. Furthermore, if skin entrance dose was reduced, the use of additional filtration may be required to be considered in many other cases.

  • PDF

A Comparative Study on Image Quality of Breast Image Tests using ACR Phantom (ACR 팬텀을 이용한 시스템별 유방검사 영상의 비교 연구)

  • Hong, Dong-Hee;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.241-247
    • /
    • 2006
  • Recently, interests and utilization on Computed Radiography(CR) and Digital Radiography(DR) tends to increase owing to an introduction of Picture Archiving and Communication System(PACS) and an accuracy control of special medical equipment for a breast imaging examination. This study was intended to compare and analyze a detector's imaging quality by each system to be used for the breast imaging examination by using ACR Phantom used at the accuracy control. As an evaluation method, a significance and reliability of image's value using the ACR Phantom was analyzed by using SPSS program. The results are followed. 1. For the fiber, there was 3.9 score in Screen-Film, 4.2 score in CR($50{\mu}m$), 3.2 score in CR($100{\mu}m$), and 4.2 score in DR. There was the high score in the order of CR($50{\mu}m$), DR, Screen-Film, and CR($100{\mu}m$)(P<0.05). 2. For the calcification, there was 2.7 score in Screen-Film, 2.5 score in CR($50{\mu}m$), 2.0 score in CR($100{\mu}m$), and 2.9 score in DR. There was the high score in the order of DR, Screen-Film, CR($50{\mu}m$), and CR($100{\mu}m$).(0.025(P<0.05). 3. For Mass, there was 3.8 score in Screen-Film, 3.8 score in CR($50{\mu}m$), 3.6 score in CR($100{\mu}m$), and 4.5 score in DR. There was the high score in the order of DR, CR($50{\mu}m$), Screen-Film, and CR($100{\mu}m$) (P<0.1). 4. As the total score, there was 10.4 score in Screen-Film, 10.6 score in CR($50{\mu}m$), 8.7 score in CR($100{\mu}m$), and 11.3 score in DR. There was the high score in the order of DR, $CR(50{\mu}m$), Screen-Film, and $CR(100{\mu}m$). As shown in the above results, it can be known that DR and Screen-Film System has higher image quality than CR. But, DR has unstability caused by element, and Screen-Film has the low image quality caused by artifact as disadvantages. When Dual-Side CR($50{\mu}m$) was used among CR systems which had the problem of low image quality, it was indicated that there was no difference with Screen-Film System. Because the radiation imaging examination tends to become digitalized, each system for the breast imaging examination will need to be developed and supplemented.

  • PDF

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF