• Title/Summary/Keyword: Digital optical imaging

Search Result 119, Processing Time 0.037 seconds

3D Holographic Image Recognition by Using Graphic Processing Unit

  • Lee, Jeong-A;Moon, In-Kyu;Liu, Hailing;Yi, Faliu
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.264-271
    • /
    • 2011
  • In this paper we examine and compare the computational speeds of three-dimensional (3D) object recognition by use of digital holography based on central unit processing (CPU) and graphic processing unit (GPU) computing. The holographic fringe pattern of a 3D object is obtained using an in-line interferometry setup. The Fourier matched filters are applied to the complex image reconstructed from the holographic fringe pattern using a GPU chip for real-time 3D object recognition. It is shown that the computational speed of the 3D object recognition using GPU computing is significantly faster than that of the CPU computing. To the best of our knowledge, this is the first report on comparisons of the calculation time of the 3D object recognition based on the digital holography with CPU vs GPU computing.

기라리(Kilali)스튜디오의 성공전략

  • Kim, Gwang-Ho
    • The Optical Journal
    • /
    • s.97
    • /
    • pp.32-34
    • /
    • 2005
  • 한국의 드라마“겨울戀歌”한편으로 일본이 떠들썩하다. 그러나 이 드라마 주인공 배용준(욘사마) 열풍은 2년 전부터 시작됐지만, 우리의‘韓流’사진은 겨울 연가보다도 더 먼저인 수년전부터 유행을 하기 시작해서 일본의 많은 사진가들이 우리나라를 찾고 있다. 변화하는 한국의 사진과 인터넷이나 디지털 사진, 세계속에 한국을 꽃피우는 훌륭한 사진들을 보기 위해 한국으로 모여들고 있고 한국의 사진은 이렇듯 일본에 있어 관심거리이다. 금년에도 코엑스에서 열리는 'Photo&Digital Imaging 2005’에 많은 일본의 사진인들이 방문할 예정이다. 한·일 사진 교류의 장이 되는 것도 중요하지만 우리의 사진이 세계의 중심이 될 수 있도록 세계의 사진을 우리가 주도해 갈 수 있도록 사진의‘韓流’를 만들자.

  • PDF

Development of monocular video deflectometer based on inclination sensors

  • Wang, Shuo;Zhang, Shuiqiang;Li, Xiaodong;Zou, Yu;Zhang, Dongsheng
    • Smart Structures and Systems
    • /
    • v.24 no.5
    • /
    • pp.607-616
    • /
    • 2019
  • The video deflectometer based on digital image correlation is a non-contacting optical measurement method which has become a useful tool for characterization of the vertical deflections of large structures. In this study, a novel imaging model has been established which considers the variations of pitch angles in the full image. The new model allows deflection measurement at a wide working distance with high accuracy. A monocular video deflectometer has been accordingly developed with an inclination sensor, which facilitates dynamic determination of the orientations and rotation of the optical axis of the camera. This layout has advantages over the video deflectometers based on theodolites with respect to convenience. Experiments have been presented to show the accuracy of the new imaging model and the performance of the monocular video deflectometer in outdoor applications. Finally, this equipment has been applied to the measurement of the vertical deflection of Yingwuzhou Yangtze River Bridge in real time at a distance of hundreds of meters. The results show good agreement with the embedded GPS outputs.

The Study on Composition ratio of Iodine in Hybrid X-ray Sensor (혼합형 X선 센서에서 a-Se 의 Iodine 첨가비 연구)

  • Gong, Hyung-Gi;Park, Ji-Koon;Choi, Jang-Yong;Moon, Chi-Wung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.366-369
    • /
    • 2002
  • At present, the study of direct digital X-ray detector and indirect digital X-ray detector proceed actively. But it needs high thickness and high voltage in selenium for high ionization rate. Therefore, we carried out the study of electric characteristics of a-Se with additive ratio of Iodine in drafting study for developing Hybrid X -ray Sensor for complementing direct digital X -ray detector and indirect digital X-ray detector in this paper. On this, there are formed Amorphous selenium multi-layers by sticking phosphor layer$(Gd_{2}O_{2}S(Eu^{2+}))$ using optical adhesives of EFIRON Co. Amorphous selenium multi-layers having dielectric layer(parylene) has characteristics of low dark-current, high X-ray sensitivity. So we can acquired a enhanced signal to noise ratio. We make Amorphous selenium multi-layers with $30{\mu}m$ thickness on glass.

  • PDF

Study on image quality improvement using Non-Linear Look-Up Table (비선형 Look-Up Table을 통한 영상 화질 개선에 관한 연구)

  • Kim, Sun-Chil;Lee, Jun-Il
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.32-44
    • /
    • 2002
  • The role of radiology department has been greatly increased in the past few years as the technology in the medical imaging devices improved and the introduction of PACS (Picture Archiving and Communications System) to the conventional film-based diagnostic structure is a truly remarkable factor to the medical history. In addition, the value of using digital information in medical imaging is highly expected to grow as the technology over the computer and the network improves. However, the current medical practice, using PACS is somewhat limited compared to the film-based conventional one due to a poor image quality. The image quality is the most important and inevitable factor in the PACS environment and it is one of the most necessary steps to more wide practice of digital imaging. The existing image quality control tools are limited in controlling images produced from the medical modalities, because they cannot display the real image changing status. Thus, the image quality is distorted and the ability to diagnosis becomes hindered compared to the one of the film-based practice. In addition, the workflow of the radiologist greatly increases; as every doctor has to perform his or her own image quality control every time they view images produced from the medical modalities. To resolve these kinds of problems and enhance current medical practice under the PACS environment, we have developed a program to display a better image quality by using the ROI optical density of the existing gray level values. When the LUT is used properly, small detailed regions, which cannot be seen by using the existing image quality controls are easily displayed and thus, greatly improves digital medical practice. The purpose of this study is to provide an easier medical practice to physicians, by applying the technology of converting the H-D curves of the analog film screen to the digital imaging technology and to preset image quality control values to each exposed body part, modality and group of physicians for a better and easier medical practice. We have asked to 5 well known professional physicians to compare image quality of the same set of exam by using the two different methods: existing image quality control and the LUT technology. As the result, the LUT technology was enormously favored over the existing image quality control method. All the physicians have pointed out the far more superiority of the LUT over the existing image quality control method and highly praised its ability to display small detailed regions, which cannot be displayed by existing image quality control tools. Two physicians expressed the necessity of presetting the LUT values for each exposed body part. Overall, the LUT technology yielded a great interest among the physicians and highly praised for its ability to overcome currently embedded problems of PACS. We strongly believe that the LUT technology can enhance the current medical practice and open a new beginning in the future medical imaging.

  • PDF

Video Rate Image Signal Processing for Optical Coherence Tomography (광학 영상기를 위한 실시간 영상 신호 처리에 관한 연구)

  • 나지훈;이병하;이창수
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.3
    • /
    • pp.239-248
    • /
    • 2004
  • Optical coherence tomography(OCT) is high resolution imaging system which can see the cross section of microscopic organs in the living tissue. In this paper, we analyze the relation between the light source and the resolution of modulated signal in Michelson interferometer. We construct 1-D OCT signal processing hardware such as amplifiers, filters, and demodulate electronic signals from the photo detector. In order to get 2-D OCT image, the synchronization among optical delay line, sample stage and A/D converter is dealt with. In experiments, we verify analog and digital signal processing blocks which apply to the stacks of glasses. Finally we aquire high resolution 2-D OCT image with respect to the onion tissue. We expect that this result can be applied to the medical instrument through performance improvement.

Evaluation of a Corrected Cam for an Interchangeable Lens with a Distance Window

  • Kim, Jin Woo;Ryu, Jae Myung;Jo, Jae Heung;Kim, Young-Joo
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.23-31
    • /
    • 2014
  • Recently, the number of camera companies that produce commercializing interchangeable lens systems such as digital single lens reflex (DSLR) and compact system camera (CSC) lenses has been gradually increasing. These interchangeable lenses have various kinds of lenses with distinct specifications. In particular, the distance window among these specifications is the function most preferred by customers. Mechanical manual zoom and manual focus in these high end camera lenses with a distance window are in particular desirable specifications and are required for product quality. However, the AF lens group is linked to the zoom cam and moves. Because the AF lens group moves along with the object distance, we can not realize the distance window with only zoom locus calculation. In this paper, in order to solve the problem, we suggest an optical calculation method for a corrected AF zoom cam for an interchangeable lens with a distance window to achieve product differentiation and analyze the error in the calculation.

Dual-wavelength Digital Holography Microscope for BGA Measurement Using Partial Coherence Sources

  • Cho, Hyung-Jun;Kim, Doo-Cheol;Yu, Young-Hun;Jung, Won-Ki;Shin, Sang-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.352-356
    • /
    • 2011
  • Dual-wavelength holography has a better axial range than single-wavelength holography, allowing unambiguous phase imaging. Partial coherence sources reduce coherent noise, resulting in improved reconstructed images. We measured a ball-grid array using dual-wavelength holography with partial coherence sources. This holography method is useful for measurement samples that exhibit coherence noise and have a step height larger than the single wavelength used in holography.

Apparatus and method for analysing spectral response of a CCD optical sensor using an infrared imaging technique (적외선 영상기법에 의한 CCD 센서의 스펙트럼 응답 특성 분석 기법)

  • Kang Seong-Jun;Na Cheol-Hun;Park Soon-Young
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.25-30
    • /
    • 2006
  • An infrared imaging method is proposed in which direct measurement of the spectral response of CCD sensors can be achieved through digital image processing. This method allows for a simple and economic method to detect the spectral sensitivity of commercialized CCD sensors. The key components of the apparatus are a monochromator, CCD-sample supporter and a personal computer equipped with a digital image processing systems. Tentative experimentation conducted on the commercialized CCD camera has resulted in a fairly consistent agreement with the theoretical model.