• Title/Summary/Keyword: Digital light processing

Search Result 189, Processing Time 0.031 seconds

Quantization Method for Normalization of JPEG Pleno Hologram (JPEG Pleno 홀로그램 데이터의 정규화를 위한 양자화)

  • Kim, Kyung-Jin;Kim, Jin-Kyum;Oh, Kwan-Jung;Kim, Jin-Woong;Kim, Dong-Wook;Seo, Young-Ho
    • Journal of Broadcast Engineering
    • /
    • v.25 no.4
    • /
    • pp.587-597
    • /
    • 2020
  • In this paper, we analyze the normalization that occurs when processing digital hologram and propose an optimized quantization method. In JPEG Pleno, which standardizes the compression of holograms, full complex holograms are defined as complex numbers with 32-bit or 64-bit precision, and the range of values varies greatly depending on the method of hologram generation and object type. Such data with high precision and wide dynamic range are converted to fixed-point or integer numbers with lower precision for signal processing and compression. In addition, in order to reconstruct the hologram to the SLM (spatial light modulator), it is approximated with a precision of a value that can be expressed by the pixels of the SLM. This process can be refereed as a normalization process using quantization. In this paper, we introduce a method for normalizing high precision and wide range hologram using quantization technique and propose an optimized method.

Experimental Study on DEM Extraction Using InSAR and 3-Pass DInSAR Processing Techniques (InSAR 및 3-Pass DInSAR 처리기법을 적용한 DEM 추출에 대한 실험 연구)

  • Bae, Sang-Woo;Lee, Jin-Duk
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.176-186
    • /
    • 2007
  • As SAR data have the strong point that is not influenced by weather or light amount in comparison with optical sensor data, they are highly useful for temporary analysis and can be collected in time of unforeseen circumstances like disaster. This study is to extract DEM from L-band data of JERS-1 SAR imagery using InSAR and DInSAR processing techniques. As a result of analyzing the extracted coherence and interferogram images, it was shown that the DInSAR 3-pass method produces more suitable coherence values than the InSAR method. The accuracies of DEM extracted from the SAR data were evaluated by employing the DEM derived from the digital topographic maps of 1:5000 scale as reference data. And it was ascertained that baselines between antenna locations largely affect the accuracy of extracted DEM.

Mapping Solar Photovoltaic Energy Resource Using LiDAR Data (LiDAR Data를 이용한 태양광에너지 자원도 제작)

  • Kim, Kwang-Deuk;Yun, Chang-Yeol;Jo, Myung-Hee;Kim, Sung-Jae
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.3
    • /
    • pp.148-157
    • /
    • 2012
  • Recently, people are getting more interested in green energy resource and environment friendly energy resource due to the lack of energy and global warming. This study produced a solar energy resource map using LiDAR(Light Detection And Ranging) data to check if it is utilized for spatial information technology and solar energy sectors that people pay more attentions to as new recycling energy. This study assigned Ulleungdo(Island) located in Gyeongsangbuk-do as a target area. This study created the contour line with 1 meter by newly photographing LiDAR and data processing. And using this contour line, this study built DEM(Digital Elevation Model) data with 1 meter. The incidence range depending on the altitude and azimuth of sun using DEM data is used to evaluate solar energy resource. This is expected to suggest an accurate method to evaluate more reliable and more precise information of new recycling energy resource by producing solar energy resource map based on accurate and precise spatial resolution data with 1 meter level.

Localization of Unmanned Ground Vehicle based on Matching of Ortho-edge Images of 3D Range Data and DSM (3차원 거리정보와 DSM의 정사윤곽선 영상 정합을 이용한 무인이동로봇의 위치인식)

  • Park, Soon-Yong;Choi, Sung-In
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.1
    • /
    • pp.43-54
    • /
    • 2012
  • This paper presents a new localization technique of an UGV(Unmanned Ground Vehicle) by matching ortho-edge images generated from a DSM (Digital Surface Map) which represents the 3D geometric information of an outdoor navigation environment and 3D range data which is obtained from a LIDAR (Light Detection and Ranging) sensor mounted at the UGV. Recent UGV localization techniques mostly try to combine positioning sensors such as GPS (Global Positioning System), IMU (Inertial Measurement Unit), and LIDAR. Especially, ICP (Iterative Closest Point)-based geometric registration techniques have been developed for UGV localization. However, the ICP-based geometric registration techniques are subject to fail to register 3D range data between LIDAR and DSM because the sensing directions of the two data are too different. In this paper, we introduce and match ortho-edge images between two different sensor data, 3D LIDAR and DSM, for the localization of the UGV. Details of new techniques to generating and matching ortho-edge images between LIDAR and DSM are presented which are followed by experimental results from four different navigation paths. The performance of the proposed technique is compared to a conventional ICP-based technique.

A Study on 3D Model Building of Drones-Based Urban Digital Twin (드론기반 도심지 디지털트윈 3차원 모형 구축에 관한 연구)

  • Lim, Seong-Ha;Choi, Kyu-Myeong;Cho, Gi-Sung
    • Journal of Cadastre & Land InformatiX
    • /
    • v.50 no.1
    • /
    • pp.163-180
    • /
    • 2020
  • In this study, to build a spatial information infrastructure, which is a component of a smart city, a 3D digital twin model in the downtown area was built based on the latest spatial information acquisition technology, the drone. Several analysis models were implemented by utilizing. While the data processing time and quality of the three types of drone photogrammetry software are different, the accuracy of the construction model is ± 0.04 in the N direction and ± 0.03m in the E direction. In the m and Z directions, ± 0.02m was found to be less than 0.1m, which is defined as the allowable range of surveying performance and inspection performance for the boundary point in the area where the registration of the boundary point registration is executed. 1: 500 to 1 of the aerial survey work regulation: The standard deviation, which is the error limit of the photographic reference point of the 600 scale, appeared within 0.14 cm, and it was found that the error limit of the large scale specified in the cadastral and aerial survey was satisfied. In addition, in order to increase the usability of smart city realization using a drone-based 3D urban digital twin model, the model built in this study was used to implement Prospect right analysis, landscape analysis, Right of light analysis, patrol route analysis, and fire suppression simulation training. Compared to the existing aerial photographic survey method, it was judged that the accuracy of the naked eye reading point is more accurate (about 10cm) than the existing aerial photographic survey, and it is possible to reduce the construction cost compared to the existing aerial photographic survey at a construction area of about 30㎢ or less.

A design method for optical fiber filter of lattice structure (격자형 광파이버필터의 설계에 관한 연구)

  • 이채욱;문병현;김신환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.9
    • /
    • pp.1248-1256
    • /
    • 1993
  • The propagation and delay properties in opical fiber are particularly attractive because digital signal processing and conventional analog signal processing techniques such as those using surface acoustic wave devices are limited In their usefulness for signal bandwidth exceeding one or two GHz, although they are very effective at lower frequencies. Since an accurate, low loss and short time delay elements can be obtained by using such an optical fiber, optical signal precessing has attracted much attention for high speed and broad-band signal precessing in particular channel separation filtering for optical FDM signals. In this paper, we consider a coherent optical lattice filter, which uses coherent light sources and consists of directional couplers and optical fiber delay elemnts. The optical fiber fitters are more restricted than the usual digital filters. The reasons are as follows. 1) the coupling coefficients of directional couplers are restricted to the number between 0 and 1. 2) optical signal E(complex amplitude) is divided into J If-$\boxUl$ and J L/7$\div$$\boxUl$ at the directional coupler. Considering these restrictions and in this case all the coupling coefficients of summing and branching elements are set to be equal, we have given design formulae for optical lattice filter, which make the best use of optical signal energy.

  • PDF

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

3D Surface Model Reconstruction of Aerial LIDAR(LIght Detection And Ranging) Data Considering Land-cover Type and Topographical Characteristic (토지피복 및 지형특성을 고려한 항공라이다자료의 3차원 표면모형 복원)

  • Song, Chul-Chul;Lee, Woo-Kyun;Jeong, Hoe-Seong;Lee, Kwan-Kyu
    • Spatial Information Research
    • /
    • v.16 no.1
    • /
    • pp.19-32
    • /
    • 2008
  • Usually in South Korea, land cover type and topographic undulation are frequently changed even in a narrow area. However, most of researches using aerial LIDAR(LIght Detection And Ranging) data in abroad had been acquired in the study areas to be changed infrequently. This research was performed to explore reconstruction methodologies of 3D surface models considering the distribution of land cover type and topographic undulation. Composed of variously undulatory forests, rocky river beds and man-made land cover such as streets, trees, buildings, parking lots and so on, an area was selected for the research. First of all, the area was divided into three zones based on land cover type and topographic undulation using its aerial ortho-photo. Then, aerial LIDAR data was clipped by each zone and different 3D modeling processes were applied to each clipped data before integration of each models and reconstruction of overall model. These kinds of processes might be effectively applied to landscape management, forest inventory and digital map composition. Besides, they would be useful to resolve less- or over-extracted problems caused by simple rectangle zoning when an usual data processing of aerial LIDAR.

  • PDF

A Study on Measurement of Internal Defects of Pressure Vessel by Digital Shearography(II) (전자 전단 간섭법을 이용한 압력용기의 내부결함 측정에 관한 연구(II) (전자 전단 간섭법을 이용한 압력용기의 내부결함 검출 시스템의 오차 분석))

  • Kang, Young-June;Park, Nak-Kyu;Ryu, Won-Jae;Kim, Dong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.402-410
    • /
    • 2002
  • Recently the necessity of study on optical measuring method using laser to detect the pipeline's defect in nuclear facilities, chemical industries and power plants has been increased. Because laser light can be delivered to a remote area without any difficulties, the application of laser in many industries can solve several difficulties from the limitation of access in danger area and reduce the risks of workers. Therefore, we applied a new experimental technique to the measurement of internal defects in pressure vessels with the combination of shearography and image processing technique and detected the internal cracks of pressure vessels in the former paper. In this paper, we used the same optical system as in the former study and found the optimum shearing magnitude by comparing the real length of specimen with experimental results. A variety of conditions were applied to certify the validity of this method. Actually, several specimens which have different lengths and depths were used in this experiment under the three diverse pressure. Consequently, we have carried out this experiment to determine the limit of measurement ability with analyzing errors.

Temporal Color Rolling Suppression Algorithm Considering Time-varying Illuminant (조도 변화를 고려한 동영상 색 유동성 저감 알고리즘)

  • Oh, Hyun-Mook;Kang, Moon-Gi
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.5
    • /
    • pp.55-62
    • /
    • 2011
  • In this paper, a temporal color and luminance variation suppression algorithm for a digital video sequence is proposed by considering time-varying light source. When a video sequence is sampled with the periodically emitting illuminant and with a short exposure time, the color rolling phenomenon occurs, where the color and the luminance of the image periodically change from field to field. In conventional signal processing techniques, the luminance variation remaining in the resultant video sequence degrades the constancy of the image sequence. In the proposed method, we obtain video sequences with constant luminance and color by compensating for the inter-field luminance variation. Based on a motion detection technique, the amount of the luminance variation for each channel is estimated on the background of the sequence without the effects of moving objects. The experimental results clearly show that our strategy efficiently estimated the illuminant change without being affected by moving objects, and the variations were efficiently reduced.