• 제목/요약/키워드: Digital X-ray System

검색결과 224건 처리시간 0.027초

DR 영상 전처리 알고리즘 및 실시간 구현을 위한 하드웨어 설계에 관한 연구 (A Study on DR Image Processing Algorithm and Hardware System for Real Time Implementation)

  • 장원석;김대현;허영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3230-3232
    • /
    • 2000
  • DR (Digital Radiography) system will be the best candidate for next generation x-ray diagnosis system. DR system will replace x-ray film by computer monitor and provide various merits like reduced processing time, easy recording, remote diagnosis and etc. In this paper, we propose the pre-processing algorithm which is designed to compensate dead and defected pixel for x-ray detector panel. We also designed DSP(Digital Signal Processor) based DR image processing board for real-time processing of suggested algorithm.

  • PDF

인버터식 X선발생장치의 출력특성개선이 환자피폭선량 경감에 미치는 효과 (The Effect on Patient Dose Reduction with Improvement of the Output Characteristics for Inverter Type X-ray Generator)

  • 노모은;이성길;김영근
    • 대한디지털의료영상학회논문지
    • /
    • 제13권1호
    • /
    • pp.27-32
    • /
    • 2011
  • The conventional types of X-ray generators were bulky in physical size and heavy in weight, and the control accuracies of the output voltages were not always satisfactory. The high frequency switching inverter and converter technology on power conversion and control systems have been greatly closed up introducing power semiconductor devices. To decreasing the volume and the weight of high voltage transformer, and to stabilize ripple. In this paper, the newly developed x-ray generator in a low cost using duty modulation PWM inverter. This system verify improved performance by stabilize ripple of X-ray tube voltage and compared the reproducibility, linearity and dose in single phase, three phase and PSU.

  • PDF

디지털 영상 합성에 의한 X선 단층 영상의 형상 정확도와 선명도 분석 (Analysis of X-ray image Qualities -accuracy of shape and clearness of image using X-ray digital tomosynthesis)

  • 노영준;조형석;김형철;김성권
    • 제어로봇시스템학회논문지
    • /
    • 제5권5호
    • /
    • pp.558-567
    • /
    • 1999
  • X-ray laminography and DT(digital tomosynthesis) that can form a cross-sectional image of 3-D objects promis to be good solutions for inspecting interior defects of industrial products. DT is a kind of laminography technique and the difference is in the fact that it synthesizes the several projected images by use of the digitized memory and computation. The quality of images acquired from the DT system varies according to image synthesizing methods, the number of images used in image synthesizing, and X-ray projection angles. In this paper, a new image synthesizing method named 'log-root method' is proposed to get clear and accurate cross-sectional images, which can reduce both artifact and blurring generated by materials out of focal plane. To evaluate the quality of cross-sectional images, two evaluating criteria : (1) shape accuracy and (2) clearness of the cross-sectional images are defined. Based on these criteria, a series of simulations are performed, and the results show the superiority of the new synthesizing method over the existing ones such as averaging and minimum methods.

  • PDF

템플릿 기반 정합 기법을 이용한 디지털 X-ray 영상의 고속 스티칭 기법 (Rapid Stitching Method of Digital X-ray Images Using Template-based Registration)

  • 조현지;계희원;이정진
    • 한국멀티미디어학회논문지
    • /
    • 제18권6호
    • /
    • pp.701-709
    • /
    • 2015
  • Image stitching method is a technique for obtaining an high-resolution image by combining two or more images. In X-ray image for clinical diagnosis, the size of the imaging region taken by one shot is limited due to the field-of-view of the equipment. Therefore, in order to obtain a high-resolution image including large regions such as a whole body, the synthesis of multiple X-ray images is required. In this paper, we propose a rapid stitching method of digital X-ray images using template-based registration. The proposed algorithm use principal component analysis(PCA) and k-nearest neighborhood(k-NN) to determine the location of input images before performing a template-based matching. After detecting the overlapping position using template-based matching, we synthesize input images by alpha blending. To improve the computational efficiency, reduced images are used for PCA and k-NN analysis. Experimental results showed that our method was more accurate comparing with the previous method with the improvement of the registration speed. Our stitching method could be usefully applied into the stitching of 2D or 3D multiple images.

On the Development of Digital Radiography Detectors: A Review

  • Kim, Ho-Kyung;Cunningham, Ian Alexander;Yin, Zhye;Cho, Gyu-Seong
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.86-100
    • /
    • 2008
  • This article reviews the development of flat-panel detectors for digital radiography based on amorphous materials, Important design parameters and developments are described for the two main components of flat-panel detectors: the X-ray converter and the readout pixel array. This article also introduces the advanced development concepts of new detectors. In addition, the cascaded linear systems method is reviewed because it is a very powerful tool for improving the design and assessment of X-ray imaging detector systems.

Computed Radiography의 영상특성에 관한 연구 (Study of Image Properties for Computed Radiography)

  • 류기현;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제10권2호
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법 (An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers)

  • 우정은;이용금;배석환;김용권
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.309-314
    • /
    • 2012
  • Digital Radiography(DR) 시스템은 임상현장에서 아날로그 시스템을 대체하고 널리 이용되고 있다. DR을 이용하여 얻어진 X선 영상의 해상력을 결정짓는 요소에는 이용되는 검출기의 고유 해상력, 피사체의 대조도 및 특성, X선 선질, X선원의 산란, DR 검출기의 성능, X선 변환효율 및 초점의 크기, 피사체의 움직임 등이 있다. DR 검출기를 구성하는 요소에는 X선 포획 요소, 커플링 요소, 정보수집 요소가 있는데 이들은 시스템의 성능에 영향을 미치며, 그 성능은 해상력으로 평가된다. 의료영상 시스템의 해상력은 촬영대상물의 조직 간의 해부학적 영상을 구분하는 능력을 나타낸다. 해상력 평가를 위해 Modulation Transfer Function(MTF)이 보편적으로 이용되고, MTF는 입력 공간주파수 성분에 대한 출력 공간주파수 성분의 비를 나타내는데, 수학적으로 MTF는 Point Spread Function(PSF) 입력에 대한 시스템의 주파수 응답이며 Edge Phantom을 이용한 결과 영상에서 추출된 Line Spread Function(LSF)을 Fourier Transform하면 얻을 수 있다. 일반적으로 임상현장에서 의료영상시스템의 이용 및 관리의 책임은 방사선사가 맡고 있지만, MTF를 측정하기 위해서는 공학적, 수학적 기초 및 C, Fortran, Matlab등의 프로그램 작성 능력이 필요하기 때문에 비 공학도는 정확한 측정이 불가능하다. 의료영상 시스템의 성능 관리 및 최상의 상태를 유지하기 위해 시스템의 성능평가가 이뤄져야 하는데, 이를 위해 본 연구에서는 비공학도가 해상력 성능평가를 할수 있도록 ImageJ 및 Excel을 이용하여 해상력 평가를 할 수 있도록 방법을 제시하고, 제안된 방법을 이용해 계산된 결과와 프로그래밍을 이용해 계산된 결과의 비교를 통해 본 논문에서 제시하는 방법의 유용성을 확인하였다.

인공신경망을 이용한 X-선 흥부영상 등화 (A study on Equalization of X-Ray Chest Radiograph using Artificial Neural Networks)

  • 이주원;이한욱;이종회;신태민;김영일;이건기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.1059-1062
    • /
    • 1999
  • Recently, X-ray chest radiograph is showing a tendency to take an image of digital radiograph so as to diagnose the pathological pattern of chest in a usual. When the radiologist observes the chest image derived from digital radiograph system on the monitor. he feels difficult to find out because of the sensitivity of chest radiograph. It takes amount of time to adjust the proper image for diagnosis. Therefore, we provided the result and the method of the optimal image equalization for image enhancement.

  • PDF

일반촬영을 위한 셀레늄 기반의 엑스선 검출기 시스템 (System of a Selenium Based X-ray Detector for Radiography)

  • 이동길;박지군;최장용;안상호;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.817-820
    • /
    • 2002
  • Amorphous selenium based flat panel detectors convert incident x-ray to electric signal directly. Flat panel detectors gain more interest real time medical x-ray imaging. TFT array and electric readout circuits are used in this paper offered by LG.Philips.LCD. Detector is based on a $1536{\times}1280$ array of a-Si TFT pixels. X-ray conversion layer(a-Se) is deposited upper TFT array with a $400{\mu}m$ by thermal deposition technology. Thickness uniformity of this layer is made of thickness control system technology$({\leq}5%)$. Each $139{\mu}m{\times}139{\mu}m$ pixel is made of thin film transistor technology, a storage capacitor and collecting electrode having geometrical fill factor of 86%. This system show dynamic performance. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system.

  • PDF

다양한 필터링 기법을 이용한 디지털 X-선 영상복원 시뮬레이션 및 정량적 화질평가 (Image Restoration Simulation of Digital X-ray Images Based upon Filtering Techniques and the Quality Evaluation of the Restored Images)

  • 이소영;최성일;오지은;조희문;이성주;박연옥;조효성
    • 한국방사선학회논문지
    • /
    • 제2권4호
    • /
    • pp.33-40
    • /
    • 2008
  • 의료영상 시스템을 통해 볼 수 있는 모든 X-선 영상은 피사체 본래의 특성만이 표현된 영상이 아닌 그 영상시스템 고유의 특성이 반영된 영상이라 할 수 있다. 영상화질에서 시스템에 의한 열화는 시스템응답함수인 변조전달 함수(modulation transfer function; MTF)로 설명되며 잡음력 스펙트럼(noise power spectrum; NPS)으로 설명할 수 있다. 이 때, 열화된 영상은 영상시스템의 MTF와 NPS를 정확하게 측정함으로써 그 시스템의 특성에 따라 설계된 필터에 의해 원영상에 가깝게 복원(restoration)될 수 있다. 본 논문에서는, 영상복원 시뮬레이션을 통해 기존의 직접 역필터링(direct-inverse filtering), 제한된 역필터링(limited-inverse filtering), 위너 필터링(Wiener filtering) 기법을 바탕으로 열화된 영상을 원 영상에 가깝도록 복원하고 복원영상의 화질을 정량적으로 평가하였다.

  • PDF