• Title/Summary/Keyword: Digital Treatment

Search Result 1,125, Processing Time 0.03 seconds

Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach (디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례)

  • Jeong, Areum;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.283-292
    • /
    • 2022
  • For fixed prosthetic treatment using implants, implants must be placed in a suitable location for prosthetic treatment. During surgery, minimally invasive prosthetic restoration is possible using a flapless method using a surgical guide. The patient in this case was an 86-year-old male patient who wanted treatment due to discomfort when using conventional dentures. Due to systemic disease, the patient had difficulty using removable local dentures, so full dentures for the maxilla and fixed implants for the mandible were restored. Because there is a high risk of bleeding due to systemic disease, the implant was placed in a flapless method using a surgical guide. Finally, prostheses were fabricated with maxillary full denture and mandibular screw-retained zirconia, and this report shows satisfactory esthetic and functional recovery.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF

Evaluation on the Accuracy of the PPS in the Proton Therapy System, Which Uses the Self Made QA Phantom (자체 제작한 QA Phantom을 이용한 양성자 PPS (Patient Positioning System)의 정확성 평가)

  • Lee, Ji-Eun;Kim, Jae-Won;Kang, Dong-Yoon;Choi, Jae-Hyeok;Yeom, Du-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.115-121
    • /
    • 2012
  • Purpose: The process of the proton treatment is done by comparing the DRR and DIPS anatomic structure to find the correction factor and use the PPS to use this factor in the treatment. For the accuracy of the patient set up, the PPS uses a 6 axis system to move. Therefore, there needs to be an evaluation for the accuracy between the PPS moving materialization and DIPS correction factor. In order to do this, we will use a self made PPS QA Phantom to measure the accuracy of the PPS. Materials and Methods: We set up a PPS QA Phantom at the center to which a lead marker is attached, which will act instead of the patient anatomic structure. We will use random values to create the 6 axis motions and move the PPS QA Phantom. Then we attain a DIPS image and compare with the DRR image in order to evaluate the accuracy of the correction factor. Results: The average correction factor, after moving the PPS QA Phantom's X, Y, Z axis coordinates together from 1~5 cm, 1 cm at a time, and coming back to the center, are 0.04 cm, 0.026 cm, 0.022 cm, $0.22^{\circ}$, $0.24^{\circ}$, $0^{\circ}$ on the PPS 6 axis. The average correction rate when moving the 6way movement coordinates all from 1 to 2 were 0.06 cm, 0.01 cm, 0.02 cm, $0.1^{\circ}$, $0.3^{\circ}$, $0^{\circ}$ when moved 1 and 0.02 cm, 0.04 cm, 0.01 cm, $0.3^{\circ}$, $0.5^{\circ}$, $0^{\circ}$ when moved 2. Conclusion: After evaluating the correction rates when they come back to the center, we could tell that the Lateral, Longitudinal, Vertical were all in the acceptable scope of 0.5 cm and Rotation, Pitch, Roll were all in the acceptable scope of $1^{\circ}$. Still, for a more accurate proton therapy treatment, we must try to further enhance the image of the DIPS matching system, and exercise regular QA on the equipment to reduce the current rate of mechanical errors.

  • PDF

The Accuracy of the Digital Imaging System and the Frequency Dependent Type Apex Locator in Root Canal Length Measurement (근관장 측정에 있어서 디지털 영상 처리기와 주파수 의존형 측정기의 정확도)

  • Lee Byaung-Rib;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.435-459
    • /
    • 1998
  • In order to achieve a successful endodontic treatment, root canals must be obturated three-dimensionally without causing any damage to apical tissues. Accurate length determination of the root canal is critical in this case. For this reason, I've used the conventional periapical radiography, Digora/sup (R)/(digital imaging system) and Root ZX/sup (R)/(the frequency dependent type apex locator) to measure the length of the canal and compare it with the true length obtained by cutting the tooth in half and measuring the length between the occlusal surface and the apical foramen. From the information obtained by these measurements, I was able to evaluate the accuracy and clinical usefulness of each systems. whether the thickness of files used in endodontic therapy has any effect on the measuring systems was also evaluated in an effort to simplify the treatment planning phase of endodontic treatment. 29 canals of 29 sound premolars were measured with #15, #20, #25 files by 3 different dentists each using the periapical radiography. Digora/sup (R)/ and Root ZX/sup (R)/. The measurements were then compared with the true length. The results were as follows: 1. In comparing mean discrepancies between measurements obtained by using periapical radiography(mean error: -0.449±0.444 mm), Digora/sup (R)/(mean error: -0.417±0.415 mm) and Root ZX/sup (R)/(mean error: 0.123±0.458 mm) with true length. periapical radiography and Digora/sup (R)/ system had statistically significant differences(p<0.05) in most cases while Root ZX/sup (R)/ showed none(p>0.05). 2. By subtracting values obtained by using periapical radiography, Digora/sup (R)/ and Root ZX/sup (R)/ from the true length and making a distribution table of their absolute values. the following analysis was possible. In the case of periapical film. 140 out of 261<53.6%) were clinically acceptable satisfying the margin of error of less than 0.5 mm. 151 out of 261 (53,6%) were acceptable in the Digora/sup (R)/ system while Root ZX/sup (R)/ had 197 out of 261(75.5%) within the limits of 0.5mm margin of error. 3. In determining whether the thickness of files has any effect on measuring methoths, no statistically significant differences were found(p>0.05). 4. In comparing data obtained from these methods in order to evaluate the difference among measuring methods, there was no statistically significant difference between periapical radiography and Digora/sup (R)/ system(p>0.05), but there was statistically significant difference between Root ZX/sup (R)/ and periapical radiography(p<0.05). Also there was statistically significant difference between Root ZX/sup (R)/ and Digora/sup (R)/ system(p<0.05). In conclusion, Root ZX/sup (R)/ was more accurate when compared with the Digora/sup (R)/ system and periapical radiography and seems to be more effective clinically in determining root canal length. But Root ZX/sup (R)/ has its limits in determining root morphology and number of roots and its accuracy becomes questionable when apical foramen is open due to unknown reasons. Therefore the combined use of Root ZX/sup (R)/ and the periapical radiography are mandatory. Digora/sup (R)/ system seems to be more effective when periapical radiographs are needed in a short period of time because of its short processing time and less exposure.

  • PDF

AN EXPERIMENTAL STUDY OF NEWLY DESIGNED IMPLANT WITH RBM SURFACE IN THE RABBIT TIBIA : RESONANCE FREQUENCY ANALYSIS AND REMOVAL TORQUE STUDY

  • Won Mi-Kyoung;Park Chan-Jin;Chang Kyoung-Soo;Kim Chang-Whe;Kim Yung-Soo;Isa Zakiahbt Mohd;Ariffin Yusnidar Tajul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.6
    • /
    • pp.720-731
    • /
    • 2003
  • Statement of problem. The importance of fixture design and surface treatment. Purpose. The clinical success of dental in plants is affected by many factors such like as degree of osseointegration, the effective load dispersion for the prostheses, and a lot of attempts have been made to overcome the difficulties. In this study, efforts were made to find the possibility of clinical acceptance of the dental implants of newly designed surface and resorbable blast media surcace. Materials and methods. In this study, two groups of custom-made, screw-shaped implants were prepared. The first with the consisting of Branemark clone design and the other with the new design. These implants were divided into four groups according to the kinds of surface treatment. Four implants($AVANA^{(R)}$, Osstem, Busan, Korea)of each group were installed in twenty rabbits. Group A was consisted of Branemark done implant left as machined, Group B with Branemark clone implants with RBM(Resorbable blast media) surface, Group C with newly designed implants left as machined and Group D with newly designed implants with RBM surface. One of the twenty rabbits died from inflammation and the observation was made for six weeks. Specimens from four groups were observed using scanning electron microscopy with 40, 100, 1000 magnification power and microsurface structures were measured by white-light scanning interferometry for three dimensional surface roughness measurements(Accura $2000^{(R)}$, Intek-Plus, Korea.). Removal torque was measured in 17 rabbits using digital torque gauge(MGT 12R, Mark-10 corp., NY, U.S.A.) immediately after the sacrifice and two rabbits were used for the histologic preparation(EXAKT $310^{(R)}$, Heraeus Kulzer, wehrheim, Germany) of specimens and observed under light microscope. Resonance frequency measurement($Osstell^{(R)}$) was taken with the 19 rabbits at the beginning of the implant fixation and immediately after the sacrifice. Results. Following results were taken from the experiment. 1. The surface of the RBM implants as seen with SEM had rough and irregular pattern with reticular formation compared to that of fumed specimens showing different surface topographies. 2. The newly designed implant with RBM surface had high removal torque value among four groups with no statistical significance. The average removal torque was $49.95{\pm}6.70Ncm$ in Group A, $51.15{\pm}4.40Ncm$ in Group B, $50.78{\pm}9.37Ncm$ in Group C, $51.09{\pm}4.69Ncm$ in Group D. 3. The RFA values were $70.8{\pm}4.3Hz$ in Group A, $71.8{\pm}3.1Hz$ in Group B, $70.9{\pm}2.5Hz$, $72.7{\pm}2.5Hz$ in Group D. Higher values were noted in the groups which had surface treatment compared to the untreated groups with no statistical significance. 4. The results from the histomorphometric evaluation showed a mean percentage of bone-to-implant contact of $45{\pm}0.5%$ in Group A, $55{\pm}3%$ in Group B, $49.5{\pm}0.5%$ in Group C, and $55{\pm}3%$ in Group D. Quite amount of newly formed bone were observed at the surface RBM-treated implants in bone marrow space.

Effects of Aerobic Exercise on Middle-aged Male Smokers' Blood Vessel Health (유산소 운동이 중년흡연남성의 혈관건강에 미치는 영향)

  • Kim, Jong-In;Jeong, Hae-Cheon;Won, Jun-Yeon;Ka, Sung-Soon;Oh, Bok-Sil
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.349-356
    • /
    • 2014
  • This research is aimed to prove if harmful effects of smoking, as the main reason for recently elevated blood vessel disease, could be reduced by aerobic exercise, and identify the positive effects of the aerobic exercise on smokers' blood vessel health(blood pressure, pulse pressure, and blood vessel elasticity. Experiments were performed on 40 male smokers aged between 40 and 55, which was equally divided into two groups of Aerobic Exercise Group (AEG) and Non Exercise Group (NEG). After measuring each group's blood pressure, pulse pressure, and blood vessel elasticity, AEG practiced aerobic exercise program for 50 minutes for each trial, three times a week, sustaining 12 weeks while NEG continued daily-life patterns without any special treatment. In 12 weeks, blood pressure, pulse pressure, and blood vessel elasticity of both groups were measured as the same way. As a result, the difference of systolic blood pressure between the two groups was not significant, while that of diastolic blood pressure was meaningful. The difference of pulse pressure between the two groups was meaningful, and that of blood vessel elasticity was also meaningful in all measuring points including left hand, right hand, left foot and right foot. As a consequent, it was found that aerobic exercise had positive effects on middle aged male smokers' blood vessel health.

The Journal of Targeted at the general public for the Modeling of Well-dying Program Development (일반인 대상 웰 다잉 교육프로그램 개발을 위한 모델링에 관한 연구)

  • Kim, Kwang-Hwan;Kim, Yong-Ha;Ahn, Sang-Yoon;Lee, Chong Hyung;Lee, Moo-Sik;Kim, Moon-Joon;Park, Arma;Hwang, Hye-Jeong;Shim, Moon-Sook;Song, Hyeon-Dong
    • Journal of Digital Convergence
    • /
    • v.12 no.8
    • /
    • pp.369-376
    • /
    • 2014
  • Death education the subject of interest is the subject of the medical staff for the death of stress degree and acceptable approach to analyze the death centered on the hospital space education in order to take advantage of From April 2014 until April 30, 281 people who lived Daejeon were surveyed. Analysis of the results, if they are taken the death education, it was considered more important than none education. If Patient in an unrecoverable state, to the question of who to notify, guardian had the highest score. Suitable for end-of-life include home, healthcare, social welfare facilities in order. When you take advantage of the results, In order to understand and take care of the phenomenon of death, we accommodate health and medical treatment perspective, humanity perspective, social perspective. It is Study for Death education program that can be applied to public. It is significant as a basis material to popularize and generalize death education program.

The Effect of Lumbosacral Stabilization Exercise on Oswestry Disability Index and Gait Velocity of Patients with Chronic Low Back Pain (허리엉치 안정화운동이 만성허리통증환자의 허리통증장애지수와 보행속도에 미치는 영향)

  • Kang, Jeong-Il;Jeong, Dae-Keun
    • Journal of Digital Convergence
    • /
    • v.11 no.8
    • /
    • pp.243-250
    • /
    • 2013
  • The present study is to determine the effect of lumbosacral stabilization exercise program on back pain disorder and gait velocity of patients with chronic low back pain. The subject was extracted randomly from 34 patients with chronic low back pain and divided into 18 patients of experimental group and 16 patients of control group. Before the experiment, the Oswestry disability index examination and analysis of gait speed were performed. Then, a conventional interventional therapy of physiotherapy was performed with the experimental group along with the lumbosacral stabilization exercise while only the conventional interventional therapy was done to the control group. Both groups did the above treatment every 30 minutes, four times a week for four weeks. Then, post-examination was carried out followed by comparing the back pain disorder index and gait velocity before and after the experiment for the two groups. The back pain disorder index showed that both experimental and control groups had significant difference within the group (p>.01)(p>.05), With regard to the gait velocity, both experimental and control groups had a significant difference within the experimental group and between the groups (p>.001)(p>.05).

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.

Study on gout screening programme in province (통풍검사 결과연구)

  • Kang, Kyung-Hee;Hwang, Hye-Jeong;Hong, Su-Min;Lim, Yeon-Hwan;Lee, Young-Hee
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.615-620
    • /
    • 2013
  • This research is a data analysis result of a future gout treatment was carried out in order to take advantage of basic data by Planned Population Federation of Korea in 2012, classified by gender. Using SPSS 18.0 analysis, frequency analysis, chi-squared analysis and logistic regression analysis were conducted. As a result, there were exceptional number of male subjects that required hyperuricemia thorough complete examination, and in case of hypouricemia, it is notable to find much more female subjects (p<0.001). Subjects that required thorough complete examination per age group and hypouricemia were significantly higher in those above the age of 70 years(p<0.001). Conclusions that required hyperuricemia thorough complete examination were a bit higher in the city areas and hypouricemia was a bit higher in the county areas, hyperuricemia was a bit higher in ratio in inland areas and hypouricemia was a bit higher in ratio in the coastal areas. I believe that continuous observation of gout prevalence rate based on this research by year, age group, and gender, would be extremely useful in making decisions regarding the changing trend of gout prevalence rate. In addition, hyperuricemia increased in postmenopausal women, as well as research on the causes of hypouricemia study.