• 제목/요약/키워드: Digital Treatment

검색결과 1,092건 처리시간 0.037초

Virtual Dissection System of Cadaver Heart Using 3-Dimensional Image

  • Chung, Min-Suk;Lee, Je-Man;Kim, Min-Koo;Park, Seung-Kyu
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.357-360
    • /
    • 1997
  • For medical students and doctors, knowledge of the 3-dimensional (3D) structure of the heart is very important in diagnosis and treatment of the heart diseases. 2-dimensional (2D) tools (e.g. anatomy book) or classical 3D tools (e.g. plastic model) are not sufficient or understanding the complex structures of the heart. Moreover, it is not always guaranteed to dissect the heart of cadaver when it is necessary. To overcome this problem, virtual dissection systems of the heart have been developed. But these systems are not satisfactory since they are made of radiographs; they are not true 3D images; they can not be used to dissect freely; or they can only be operated on the workstation. It is also necessary to make the dissection systems incorporating the various races and tribes because of the organ's difference according to race and tribe. This study was intended to make the 3D image of the heart from a Korean cadaver, and to establish a virtual dissection system of the heart with a personal computer. The procedures or manufacturing this system were as follows. 1. The heart from a Korean adult cadaver was embedded with gelatin solution, and serially cross-sectioned at 1mm-thickness on a meat slicer. Pictures or 153 cross-sectioned specimens were inputted into the computer using a digital camera ($756{\times}504$ resolution, true color). 2. The alignment system was established by means of the language of IDL, and applied to align 2D images of the heart. In each of 2D images, closed curves lining clean and dirty blood pathways were drawn manually on the CorelDRAW program. 3. Using the language of IDL, the 3D image and the virtual dissection system of the heart were constructed. The virtual dissection system of the heart allowed or ree rotation, any-directional sectioning, and selected visualization of the heart's structure. This system is expected to become more advanced, and to be used widely through Internet or CD-title as an educational tool for medical students and doctors.

  • PDF

C-Arm 장비의 사용 시 시술자의 피폭선량 저 감화 방법 연구 (Study on the Method for Reducing the Operator's Exposure Dose From a C-Arm System)

  • 김기식;송종남;김승옥
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.493-499
    • /
    • 2016
  • C-arm장비의 사용 시 시술자의 산란선에 의한 피폭선량을 확인하여 적절하고 효율적인 피폭선량 저 감화 방법을 알아보기 위해 본 연구를 진행하였다. Over Tube 방식에 비해 피폭선량이 적다는 Under Tube 방식의 C-arm 장비를 활용하여 연구한 결과 차폐도구가 두꺼울수록 시술자의 피폭선량은 감소하였고, 중심선에서 멀어질수록 피폭선량이 감소하였고, 조사시간이 길어질수록 피폭선량이 증가하였고, 세 곳의 선량계 부착위치 중 생식선에서 가장 많은 피폭선량이 측정되었고 흉부, 갑상선 순이었다. 그러나 실제 시술 중 피폭선량을 줄이기 위해 거리를 무한정 늘릴 수 없고, 조사시간을 무한정 단축시킬 수 없기 때문에 인위적으로 조절 가능한 차폐 두께를 달리하는 방법으로 시술자의 피폭선량을 감소시킬 수 있었다. C-arm장비를 사용할 경우 시술 중 불편하다는 이유로 방사선 차폐에 소홀히 하고 근접시술이 이루어지기 때문에 피폭량은 증가할 수밖에 없다. 이에 C-Arm장비의 특성상 조정실을 구비할 수 없으므로 Apron 등의 방사선 차폐도구의 적정두께 사용 등으로 시술 중 발생되는 방사선에 의한 시술자의 피폭선량을 경감시켜야 할 것으로 사료된다.

UWB/WiFi 모듈 기반의 내시경 카메라용 무선전송 설계 (Design of UWB/WiFi Module based Wireless Transmission for Endoscopic Camera)

  • 심동하;이재곤;이재선;차재상;강민구
    • 인터넷정보학회논문지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2015
  • 본 논문에서는 초광각 무선 내시경을 제안하고 구현하였다. 내시경은 초광각 카메라 모듈과 무선전송 모듈로 구성된다. 162도의 초광광 렌즈와 이미지 센서 및 카메라 프로세서가 $3{\times}3{\times}9cm3$ 크기의 케이스에 함께 패키지 된다. 무선전송 모듈로 UWB 기반 및 WiFi 기반의 플랫폼을 각각 구현한다. UWB 기반 모듈은 의 고화질 영상을 MJPEG로 압축하여, $2048{\times}1536$ (QXGA)의 해상도에서 15 fps의 속도로 영상을 전송하며, 최대 데이터 전송속도는 41.2 Mbps에 달한다. 구현된 내시경은 의료용 내시경의 화각과 해상도 수준을 가지며, 상용 고성능 WiFi 내시경과 비교할 때 ~3X의 화각과 16X의 해상도를 갖는다. WiFi 기반의 모듈은 $640{\times}480$ (VGA)의 해상도에서 30 fps의 속도로 영상을 스마트 기기로 스트리밍 하며, 최대 1.5 Mbps의 데이터 전송속도를 보여준다. 구현된 모듈은 저가격의 의료용 무선 전자 내시경의 구현 가능성을 보여주며, U-헬스케어, 응급처치, 가정의료, 원격진료 등에 효과적으로 활용될 수 있을 것으로 기대된다.

구강스캐너를 이용하여 제작된 CT 가이드 임플란트 수술용 형판의 무치악 거리에 따른 정확도 분석 (Accuracy of the CT guided implant template by using an intraoral scanner according to the edentulous distance)

  • 강병길;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제55권1호
    • /
    • pp.1-8
    • /
    • 2017
  • 목적: 이 연구의 목적은 구강스캐너를 이용하여 제작된 임플란트 수술용 형판의 무치악 거리에 따른 정확성을 비교하는 것이다. 재료 및 방법: 방사선불투과성 아크릴 레진을 이용하여 상악 좌우 제2소구치, 제1대구치, 제2대구치 부위를 치아상실 상태로 5개의 상악 모형을 제작하고 각각의 모형을 구강스캐너를 이용하여 가상 모형을 획득하였다. 모형의 술전 CT DICOM file과 가상의 모형을 중첩 후 치아 상실 부위에 임플란트 식립을 계획하였고 제작된 수술용 형판을 이용하여 임플란트 식립 후 술후 CT 촬영을 시행하였다. 술전 CT와 술후 CT를 software상에서 중첩 후 X, Y, Z축을 이용하여 임플란트의 platform과 apex 부위에서, 계획된 임플란트와 실제 식립된 임플란트의 거리 및 각 오차를 측정하고 Kruskall-Wallis test와 Mann-Whitney test를 사용하여 통계분석을 시행하였다. 결과: 임플란트 식립 각도 오차는 제2소구치에서 제2대구치로 갈수록 커졌으나 통계적 차이를 보이지 않았고 platform 부위와 apex부위에서의 식립 거리 오차 또한 제2소구치에서 제2대구치로 갈수록 커지나 제2대구치에서는 통계적으로 유의성 있는 큰 오차를 보였다. 결론: 임플란트 식립 각도에서는 계획된 임플란트와 식립된 임플란트간 통계적 차이는 없었으나 platform과 apex 부위에서의 식립 거리는 제2대구치 부위의 임플란트에서 더 큰 오차를 보였으며 통계적으로 유의할 만한 차이를 보였다.

짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구 (Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants)

  • 명태수;정승현;김태영;김유리
    • 구강회복응용과학지
    • /
    • 제28권1호
    • /
    • pp.1-13
    • /
    • 2012
  • 짧은 임플란트는 상악동이나 하치조신경 등의 해부학적 구조물이 있거나 심한 치조골 흡수로 인해 제한적인 치조제 높이를 가지는 부위에서 사용되고 있다. 본 연구는 길이 10 mm 이하의 임플란트에서 임플란트의 길이, 직경, 식립 부위, 골이식술 유무, 보철물의 연결고정 유무가 임플란트의 생존율과 변연골 흡수에 미치는 영향을 알아보고자 하였다. 원광대학교 치과병원 임플란트센터에서 길이 10 mm 이하의 임플란트를 식립한 137명의 환자, 227개 임플란트를 대상으로 진료 기록부를 통해 임플란트의 길이, 직경, 식립 위치, 골이식 유무, 보철물의 연결고정 유무를 조사하였다. 변연골 흡수량은 Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands) 프로그램을 이용하여 측정하였다. 총 227개의 임플란트 중 8개가 실패하여, 전체 짧은 임플란트의 생존율은 96.5 %로 나타났다. 골이식 부위와 상악에 식립된 경우 더 높은 실패율을 보이는 경향이 있었으며, 임플란트의 길이와 직경은 변연골 흡수량에 영향을 미치지 않았다. 실패 요인을 조사하였을 때, 상악의 불량한 골질과 골이식 유무가 임플란트의 더 높은 실패율에 영향을 미쳤다. 10 mm 이하 임플란트에서 길이, 직경, 식립 부위, 골이식술과 보철물의 연결 고정은 임플란트 생존율과 변연골 흡수량에 영향을 끼치지 않았다.

무수치 표백술에서 근관내 Base가 표백약제의 누출 방지에 미치는 영향 (THE EFFECT OF INTRACANAL BASE ON PREVENTION OF APICAL LEAKAGE OF BLEACHING AGENTS)

  • 최승호;노병덕;박성호;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.453-464
    • /
    • 1999
  • The non-vital bleaching technique has been used widely as a very effective treatment method on discolored non-vital teeth. But periodontal tissue deterioration and cervical external root resorption have been reported because of the high toxicity of hydrogen peroxide in bleaching agents. So in previous studies, placement of base over the root canal obturation prior to bleaching has been suggested in order to prevent microleakage of bleaching agents, however, the effectiveness of base is still controversial. The purpose of this study was to evaluate the effects of base and root canal sealer on prevention of leakage of bleaching agents in non-vital bleaching. Fifty-two extracted sound teeth with single root were used. For root canal obturation, Tubuli seal$^{(R)}$(Kerr Co., USA) was used in 39 teeth and in others, AH-26$^{(R)}$(De Trey Dentsply, Inc., Switzerland) was used as a root canal sealer. 26 teeth among the teeth obturated with Tubuli seal$^{(R)}$ were divided into two groups, and Dentin cement$^{(R)}$(GC corp., Japan) and JRM$^{(R)}$(De Trey Dentsply, Inc. Germany) were used in each group as a intracanal base. In all teeth, non-vital bleaching using bleaching agent mixed with methylene blue dye was performed and all specimens were stored in $37^{\circ}C$ water bath for 72 hours. After sectioning longitudinally, the depth of dye leakage was measured with digital vernier calipers under the stereobinocular microscope using ${\times}40$ magnification. It can be concluded as follows: 1. The microleakage of bleaching agent was observed ill all groups regardless of type of the base and the sealer. 2. The microleakage in the groups using AH-26$^{(R)}$ as a sealer was significantly reduced (p<0.05). 3. In the groups with intracanal base, micro leakage was observed through almost the whole depth of the base and there was no significant difference between Dentin cement$^{(R)}$ and IRM$^{(R)}$ group(p>0.05). In conclusion, all the basing materials and the sealers in this study did not prevent the microleakage of bleaching agent. Therefore further studies and attempts to seal off the pulp chamber will be necessary.

  • PDF

Cyanidin-3-glucoside Inhibits ATP-induced Intracellular Free $Ca^{2+}$ Concentration, ROS Formation and Mitochondrial Depolarization in PC12 Cells

  • Perveen, Shazia;Yang, Ji Seon;Ha, Tae Joung;Yoon, Shin Hee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제18권4호
    • /
    • pp.297-305
    • /
    • 2014
  • Flavonoids have an ability to suppress various ion channels. We determined whether one of flavonoids, cyanidin-3-glucoside, affects adenosine 5'-triphosphate (ATP)-induced calcium signaling using digital imaging methods for intracellular free $Ca^{2+}$ concentration ([$Ca^{2+}$]i), reactive oxygen species (ROS) and mitochondrial membrane potential in PC12 cells. Treatment with ATP ($100{\mu}M$) for 90 sec induced [$Ca^{2+}$]i increases in PC12 cells. Pretreatment with cyanidin-3-glucoside ($1{\mu}g/ml$ to $100{\mu}g/ml$) for 30 min inhibited the ATP-induced [$Ca^{2+}$]i increases in a concentration-dependent manner ($IC_{50}=15.3{\mu}g/ml$). Pretreatment with cyanidin-3-glucoside ($15{\mu}g/ml$) for 30 min significantly inhibited the ATP-induced [$Ca^{2+}$]i responses following removal of extracellular $Ca^{2+}$ or depletion of intracellular [$Ca^{2+}$]i stores. Cyanidin-3-glucoside also significantly inhibited the relatively specific P2X2 receptor agonist 2-MeSATP-induced [$Ca^{2+}$]i responses. Cyanidin-3-glucoside significantly inhibited the thapsigargin or ATP-induced store-operated calcium entry. Cyanidin-3-glucoside significantly inhibited the ATP-induced [$Ca^{2+}$]i responses in the presence of nimodipine and ${\omega}$-conotoxin. Cyanidin-3-glucoside also significantly inhibited KCl (50 mM)-induced [$Ca^{2+}$]i increases. Cyanidin-3-glucoside significantly inhibited ATP-induced mitochondrial depolarization. The intracellular $Ca^{2+}$ chelator BAPTA-AM or the mitochondrial $Ca^{2+}$ uniporter inhibitor RU360 blocked the ATP-induced mitochondrial depolarization in the presence of cyanidin-3-glucoside. Cyanidin-3-glucoside blocked ATP-induced formation of ROS. BAPTA-AM further decreased the formation of ROS in the presence of cyanidin-3-glucoside. All these results suggest that cyanidin-3-glucoside inhibits ATP-induced calcium signaling in PC12 cells by inhibiting multiple pathways which are the influx of extracellular $Ca^{2+}$ through the nimodipine and ${\omega}$-conotoxin-sensitive and -insensitive pathways and the release of $Ca^{2+}$ from intracellular stores. In addition, cyanidin-3-glucoside inhibits ATP-induced formation of ROS by inhibiting $Ca^{2+}$-induced mitochondrial depolarization.

하악 제 2 유구치 근관 만곡의 방사선학적 계측 (THE RADIOGRAPHICAL MEASUREMENT OF ROOT CANAL CURVATURE OF MANDIBULAR PRIMARY 2ND MOLARS)

  • 김영종;정태성;김신
    • 대한소아치과학회지
    • /
    • 제30권4호
    • /
    • pp.637-642
    • /
    • 2003
  • 유치근의 치근이개와 만곡에 관련된 형태학적 특성은 치열교환기의 치근 흡수 및 근단 병소의 양상을 결정지을 뿐 아니라, 성공적인 치수치료에 심대한 영향을 미친다. 본 연구는 하악 제 2유구치 근관 만곡의 각도, 반경 및 만곡 시작점을 측정해 봄으로써, 유치근과 근관의 해부학적 형태를 정밀 분석할 목적으로 시행되었다. 연구재료로는 $3{\sim}6$세의 어린이의 제 2 유구치 구내 치근단 방사선 사진 50매를 사용하였다. 근단공이 미완성이거나 흡수된 것을 제외하고, 방사선상의 왜곡이 적으며 근관 형태의 판독이 가능한 것을 선택하고, 자료를 digital image화하여 이미지 분석용 software Scion Image Beta 4.02 (Scion Co. USA)를 이용하여 만곡을 분석하였다. 그리고 Schneider법에 의해 만곡도를 측정하고, Schaefer 등의 방법에 의해 만곡반경을 측정하였으며, 아울러 만곡개시거리를 측정하고 근원심근 간의 비교를 통하여 다음과 같은 결과를 얻었다. 1. 제 2유구치의 만곡도는 근심근에서 $17.3^{\circ}{\pm}5.0$, 원심근에서 $27.9^{\circ}{\pm}6.0$로 원심근에서 크게 나타났다(p<0.05). 2. 만곡반경은 근심근에서 $8.7\;mm{\pm}2.5$, 원심근에서 $5.8\;mm{\pm}1.5$로 근심근에서 크게 나타났다(p<0.05). 3. 만곡개시거리는 근심근에서 $4.1\;mm{\pm}0.6$, 원심근에서 $4.2\;mm{\pm}0.6$로 양 근간에 차이가 없었다(p<0.05).

  • PDF

표면처리 임플란트 고정체의 의원성 동요 후 시간 경과에 따른 재골유착에 관한 연구 (An investigation of reosseointegration according to time course after mechanical loosening of the osseointegrated implant fixtures)

  • 예선혜;조진현;이청희
    • 구강회복응용과학지
    • /
    • 제31권3호
    • /
    • pp.203-211
    • /
    • 2015
  • 목적: 완전한 골-임플란트 결합을 가졌던 임플란트가 갑자기 골유착을 잃은 경우의 시간에따른 재골유착을 연구하기 위함이다. 연구 재료 및 방법: 23마리 토끼의 좌우 경골에 각각 2개씩 실험목적으로 제작한 RBM임플란트를 식립 후, 6주 후에 1차로 비틀림 제거력을 측정한 다음, 임플란트를 다시 재위치 침하시키고, 4일, 7일, 11일, 2주, 4주, 6주, 그리고 8주의 재침하시간 경과 후 2차로 비틀림 제거력을 측정하고 시편을 제작하여 조직 형태학적 검사를 하였다. 통계학적 검사를 위해 paired t-test를 시행했고, One-way ANOVA와 Tukey's post-hoc test 통해 그룹간 차이를 비교하여 다음과 같은 결과를 얻었다. 결과: 1차 비틀림 제거력과 비교해봤을 때 2차에서 11일 후에는 증가했으며, 2주 후부터 유의성 있게 증가하였다. 형광조사검사에서, 7일 후부터 골-임플란트 계면 사이에 형광밴드가 나타나는 광물화 현상이 관찰되고, 11일 후부터는 분명한 골 형성이 나타났다. 결론: 토끼에서는 11일 이후가 되면 충분한 재골유착을 얻을 수 있었다.

전자계약에 관한 연구 (Study on the Electronic Contract)

  • 김재남;박종렬
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권6호
    • /
    • pp.129-138
    • /
    • 2014
  • 전자계약이란 과거 계약 당사자들이 대면으로 만나서 처리하던 계약서 작성 서명 관리 등의 일련의 계약 업무를 공인인증서 기반의 전자서명 및 암호화를 통해 시간과 공간의 제약 없이 온라인으로 계약서를 작성 체결 관리 보관하는 것을 의미한다. 최근 정보통신기술의 눈부신 발전과 초고속인터넷의 서비스가 보급되면서 이를 이용해서 이루어지는 거래계약으로 일정한 법률효과를 목적으로 두 사람 이상의 당사자가 전자적 의사 표시의 합의인 법률행위를 통하여 기업 생산성 향상 외에도 계약서류와 실제 구매 입고 지급 같은 전 과정을 조정할 수 있는 이점이 많아 급속도로 새로운 경제활동의 영역의 축으로 급부상하고 있는 것이 현실이다. 이러한 시대변화 속에서 전자계약의 성립과 관련하여 민법상 계약의 핵심인 당사자의 의사표시 등에 대하여 전혀 예상하지 못한 법률적인 여러 가지 문제점이 대두되고 있어 체계적인 법리구성이 요구되는 실정이다. 이에 따라 본 연구에서는 전자계약에 따른 문제점에 대한 고찰을 통하여 합리적인 개선방안을 제시하고자 한다.