• 제목/요약/키워드: Digital Therapy

검색결과 631건 처리시간 0.027초

멕켄지 운동 적용에 따른 전방머리자세와 족저압의 상관관계 (The Correlation Between Forward Head Posture Used McKenzie Exercise and Plantar Pressure)

  • 한지훈;김정현;정민근;주태성;전재국
    • 대한정형도수물리치료학회지
    • /
    • 제22권1호
    • /
    • pp.65-70
    • /
    • 2016
  • Background: To determine the correlation Between forward head posture and plantar pressor in a McKenzie Exercise. Methods: This study had a cross-sectional design. There are included 20 participants with forward head posture. We measured the craniovertebral angle (CVA), cranial rotation angle (CRA) by image obtained digital camera and the plantar pressure, static balance using Gait Analyzer each before and after McKenzie Exercise. Results: There was negative correlation between CVA and CRA (p<.05). There was negative correlation between CVA and fore foot(p<.05). There was positive correlation between CRA and both fore foot (p<.05). There was negative correlation between CVA and static balance(p<.05). There was positive correlation between CRA and static balance (p<.05). Conclusions: There is a correlation between the change a mount of forward head position and plantar pressure in the McKenzie Exercise.

  • PDF

백서의 적출창상에 대한 피하전기자극이 창상수축에 미치는 효과 (Wound Contraction Effects of Percutaneous Electrical Stimulation on Excision Wound Models)

  • 공광식;김수현;오석;김용남;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제23권1호
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: This study investigated the effect of needle electrode stimulation at various frequencies on change in wound healing in excision wound rats Methods: Twenty-four Sprague-Dawley adult male rats were assigned to one of four groups: control (n=6), acupuncture group (n=6), low rate (2 Hz) percutaneous electrical stimulation group, high rate (100 Hz) percutaneous electrical stimulation group (n=6). We analyzed morphological effects by measuring the area of the excision wound, the contraction rate, and chromatic red. A digital camera and an image analysis program were used to measure and analyze the wound area,which was also used for the contraction rate. Chromatic red was obtained by calculating red, green, and blue (RGB) values of the wound area. Results: The electro acupuncture stimulation groupsshowed significant healing effects compared to the control and acupuncture groups. Conclusion: The results of this study showed that various frequencies of percutaneous electrical stimulation have a therapeutic effect on wound healing.

재활치료와 기능성게임 (Rehabilitation and Serious Games)

  • 김황용
    • 디지털융복합연구
    • /
    • 제12권4호
    • /
    • pp.69-73
    • /
    • 2014
  • 게임은 재미를 추구하지만 게임을 통해 다양한 긍정적 효과도 얻을 수 있다. 이러한 게임의 긍정적 효과를 이용하여 특정 목적을 달성하는 게임이 기능성게임이다. 본 논문에서는 기능성게임과 재활치료에 대하여 알아본다. 또한, 의료용 기능성게임의 유형과 재활치료용 기능성게임의 개발 실태를 알아보고, 재활치료용 기능성게임의 이용 활성화 방안을 제시한다.

방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작 (Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments)

  • 차동수;이재승
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF

Development of a Mobile Application for Effective Mental Health Intervention

  • Mousab Issa Alhamada;Khairayu Badron
    • International Journal of Computer Science & Network Security
    • /
    • 제23권8호
    • /
    • pp.33-39
    • /
    • 2023
  • The global surge in depression and anxiety, intensified by challenges such as cost and stigma, emphasizes the pressing need for accessible, evidence-based digital solutions. The research centers on the creation of a mobile application specifically designed to address mental health challenges. By integrating cognitive behavioral therapy techniques and features like appointment bookings and mindfulness feedback tools, the app is positioned to improve user outcomes. Utilizing platforms like React Native and React, combined with NestJS for enhanced backend security, the application adheres to the rigorous standards required for mental health interventions. Collaborative efforts with experts, notably the counseling unit of IIUM, ensure the app's alignment with contemporary best practices and research. Preliminary findings indicate a promising tool with the potential to address the global mental health treatment disparity.

손목 · 손가락 관절가동범위 측정에 관한 3차원 동작분석 프로그램의 신뢰도 연구 (Reliability Study of Three-Dimensional Motion Analysis Program for Wrist and Finger Joint Range of Motion Measurement)

  • 박선하;박지혁;김종배;정영진;이주현;박혜연
    • 재활치료과학
    • /
    • 제12권1호
    • /
    • pp.79-92
    • /
    • 2023
  • 목적 : 본 연구는 손목과 손가락 관절가동범위 측정에 대한 3차원 동작분석 프로그램의 신뢰도를 알아보고자 하였다. 연구방법 : 연구 대상자는 정상인으로 손목과 손가락의 움직임에 제한이 없는 자, 본 연구의 목적을 이해하고 참여에 동의한 자 50명을 대상으로 하였다. 측각기와 3차원 동작분석 프로그램을 사용하여 총 11항목의 손목과 손가락 관절가동범위를 각각 1회씩 측정하였다. 3차원 동작분석 프로그램의 신뢰도를 측정하기 위해 측정값의 일치도와 불일치 양상을 비교하였다. 결과 : 측정값의 일치도를 분석한 결과 44개의 항목 중 38개 측정항목에서 매우 높은 일치도를 보였으며, 측정값의 불일치 양상을 분석한 결과 3가지 항목에서 불일치 양상이 나타났다. 결론 : 본 연구 결과를 통해 본 연구에서 사용한 3차원 동작분석 프로그램을 통해 관절가동범위 측정이 가능함을 알 수 있었다. 또한 3차원 동작분석 프로그램의 측정의 편리성, 정확성의 장점을 기반으로 다양한 임상 분야에서 활용되기를 기대한다.

방사선 치료위치 검증을 위한 다이오드 검출기의 특성에 관한 연구 (A Study on Characteristics of Diode Detecter for Verification of Radiation Therapy)

  • 이동훈;김윤종;지영훈;이동한;홍승홍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.106-109
    • /
    • 2000
  • The diode characteristics for therapy radiation sensor have been studied by irradiating therapy radiation from the MM22 microtron accelerator. Signal processing has been performed in the pulse mode which can process the signal fast. We have designed integrator, peak detector and synchronization circuit to detect diode signal in the pulse mode for implementation of portal image. We also read the diode signal by A/D board and displayed the peak value with LabView program. Because the quality of portal image obtained by film in the case of therapy radiation is much worse than that of diagnostic film, Digital radiography system by rectifier diode detector was suggested for portal Image.

  • PDF

발목의 Dorsiflexion과 Plantarflexion의 치료 (Treatment for Abnormalities When Raising Arms)

  • 신성윤;이현창
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2017년도 제56차 하계학술대회논문집 25권2호
    • /
    • pp.342-343
    • /
    • 2017
  • 본 논문에서는 만성 발목 불안정성이 있는 환자의 발목 재손상을 예방하고자 한다. 이를 위하여 발목의 안쪽 굽힙(Dorsiflexion)과 바깥쪽 굽힘(Plantarflexion)의 각도를 측정한다. 각도가 일정 범위 내에 있고 고통을 호소하지 않으면 정상으로 간주한다. 하지만 각도가 일정 범위에 못 미치고 고통을 호소하면 이상이 있는 것으로 간주하여 그에 대한 치료법(therapy)을 찾아낸다.

  • PDF

단순 방사선 영상기반 바이오마커를 활용한 흉·요추의 추나의학적 변위 진단 방법 (Radiograph-based Diagnostic Methods for Thoracic and Lumbar Spine Malposition in Chuna Manual Therapy Using Biomarkers)

  • 이진현;최민호;김중일;장준수;박태용
    • 척추신경추나의학회지
    • /
    • 제18권2호
    • /
    • pp.1-8
    • /
    • 2023
  • Objectives This study aimed to propose biomarkers for diagnosing Chuna manual therapy (CMT) based on X-ray images in the thoracic and lumbar spines. Methods Through a literature review and expert consensus process, diagnostic biomarkers for CMT were selected based on the listing system in thoracic and lumbar radiograph anterior-posterior (AP) and lateral views. Results 1. Diagnostic biomarkers were derived from four points on the outer contour of the vertebral body in the thoracic and lumbar spine radiograph lateral view, enabling the diagnosis of flexion and extension malposition. 2. Additional diagnostic biomarkers were identified in the thoracic and lumbar radiographAP view, utilizing points on the outer contour of the vertebral body. These biomarkers facilitate the diagnosis of lateral bending. Moreover, biomarkers derived from the innermost point of the pedicle contour allow for the diagnosis of rotation malposition. 3. Furthermore, through the biomarkers proposed in this study, all malpositions of the thoracolumbar spines and complex Type I and II malpositions can be diagnosed in CMT. Conclusions The biomarkers reported in this study consist of minimal points to determine the position of the vertebral body, providing the advantage of simplicity while minimizing potential errors during the CMT diagnostic process. Further clinical research and the development of related programs should be pursued to expand the evidence for CMT.