• Title/Summary/Keyword: Digital Therapy

Search Result 631, Processing Time 0.024 seconds

The Correlation Between Forward Head Posture Used McKenzie Exercise and Plantar Pressure (멕켄지 운동 적용에 따른 전방머리자세와 족저압의 상관관계)

  • Han, Ji-Hoon;Kim, Jung-Hyun;Jung, Min-Keun;Ju, Tae-seong;Jeon, Jae-guk
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.65-70
    • /
    • 2016
  • Background: To determine the correlation Between forward head posture and plantar pressor in a McKenzie Exercise. Methods: This study had a cross-sectional design. There are included 20 participants with forward head posture. We measured the craniovertebral angle (CVA), cranial rotation angle (CRA) by image obtained digital camera and the plantar pressure, static balance using Gait Analyzer each before and after McKenzie Exercise. Results: There was negative correlation between CVA and CRA (p<.05). There was negative correlation between CVA and fore foot(p<.05). There was positive correlation between CRA and both fore foot (p<.05). There was negative correlation between CVA and static balance(p<.05). There was positive correlation between CRA and static balance (p<.05). Conclusions: There is a correlation between the change a mount of forward head position and plantar pressure in the McKenzie Exercise.

  • PDF

Wound Contraction Effects of Percutaneous Electrical Stimulation on Excision Wound Models (백서의 적출창상에 대한 피하전기자극이 창상수축에 미치는 효과)

  • Gong, Gwang-Sik;Kim, Su-Hyon;Oh, Seok;Kim, Yong-Nam;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.1
    • /
    • pp.45-51
    • /
    • 2011
  • Purpose: This study investigated the effect of needle electrode stimulation at various frequencies on change in wound healing in excision wound rats Methods: Twenty-four Sprague-Dawley adult male rats were assigned to one of four groups: control (n=6), acupuncture group (n=6), low rate (2 Hz) percutaneous electrical stimulation group, high rate (100 Hz) percutaneous electrical stimulation group (n=6). We analyzed morphological effects by measuring the area of the excision wound, the contraction rate, and chromatic red. A digital camera and an image analysis program were used to measure and analyze the wound area,which was also used for the contraction rate. Chromatic red was obtained by calculating red, green, and blue (RGB) values of the wound area. Results: The electro acupuncture stimulation groupsshowed significant healing effects compared to the control and acupuncture groups. Conclusion: The results of this study showed that various frequencies of percutaneous electrical stimulation have a therapeutic effect on wound healing.

Rehabilitation and Serious Games (재활치료와 기능성게임)

  • Kim, Hwangyong
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.69-73
    • /
    • 2014
  • We pursue pleasure through game but also possibly get positive effects. The serious game is a game that achieves a certain goal by using the positive effects of games. This paper describes the serious game and rehabilitation. Also, it describes the types of medical serious games and actual development condition of serious games for rehabilitation, and suggest ways to inspire utilization of the serious games for rehabilitation.

Manufacture of Versatile Phantom for the Daily Quality Assurance of Radiation Therapy Equipments (방사선치료 장비들의 매일 정도관리를 위한 다용도 모형의 제작)

  • Cha, Dong-Soo;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.59-64
    • /
    • 2010
  • We examined the accuracy and efficiency of phantom by applying the designed phantom in order to check daily quality assurance easily by objective criteria and to confirm daily quality assurance of linear accelerator, simulator, and CT-simulator. The results of 10 weeks of linear accelerator output dose using American Association of Physicists in Medicine(AAPM) daily quality assurance guide were measured within ${\pm}1%$ of error. Mechanical check of laser alignment, optical distance indicator(ODI), CT scanner laser and alignment of gantry lasers with the center of imaging plane were measured within ${\pm}1mm$. Daily average working time for daily quality assurance of radiation therapy equipments was 38 minutes. The designed phantom was easy to install and daily quality assurance was possible with only one installation. The aspects reproducibility and efficiency as well as accuracy of quality assurance were excellent.

  • PDF

Development of a Mobile Application for Effective Mental Health Intervention

  • Mousab Issa Alhamada;Khairayu Badron
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.8
    • /
    • pp.33-39
    • /
    • 2023
  • The global surge in depression and anxiety, intensified by challenges such as cost and stigma, emphasizes the pressing need for accessible, evidence-based digital solutions. The research centers on the creation of a mobile application specifically designed to address mental health challenges. By integrating cognitive behavioral therapy techniques and features like appointment bookings and mindfulness feedback tools, the app is positioned to improve user outcomes. Utilizing platforms like React Native and React, combined with NestJS for enhanced backend security, the application adheres to the rigorous standards required for mental health interventions. Collaborative efforts with experts, notably the counseling unit of IIUM, ensure the app's alignment with contemporary best practices and research. Preliminary findings indicate a promising tool with the potential to address the global mental health treatment disparity.

Reliability Study of Three-Dimensional Motion Analysis Program for Wrist and Finger Joint Range of Motion Measurement (손목 · 손가락 관절가동범위 측정에 관한 3차원 동작분석 프로그램의 신뢰도 연구)

  • Park, Sun Ha;Park, Ji-Hyuk;Kim, Jong Bae;Jung, Young Jin;Lee, Joo Hyun;Park, Hae Yean
    • Therapeutic Science for Rehabilitation
    • /
    • v.12 no.1
    • /
    • pp.79-92
    • /
    • 2023
  • Objective : This study aimed to assess the reliability of a three-dimensional (3D) motion analysis program for measuring the range of motion (ROM) of wrist and finger joints. Methods : The study recruited 50 people who had no restrictions on wrist and finger movements, understood the purpose of this study, and agreed to participate. Using a goniometer and a 3D motion analysis program, a total of 11 wrist and finger ROM were measured once each. To measure the reliability of the 3D motion analysis program, the degree of agreement and inconsistency of the measured values were compared. Results : Analysis of the degree of agreement of the measured values revealed that 38 out of 44 items showed a very high degree of agreement. Regarding analysis of inconsistency in the measured values, inconsistencies were found in three items. Conclusion : The results of this study confirmed that the ROM of the joint could be measured using the 3D motion analysis program applied in this study. In addition, it might be expected that the 3D motion analysis program would be used in various clinical fields owing to the advantages of measurement convenience and accuracy.

A Study on Characteristics of Diode Detecter for Verification of Radiation Therapy (방사선 치료위치 검증을 위한 다이오드 검출기의 특성에 관한 연구)

  • 이동훈;김윤종;지영훈;이동한;홍승홍
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.106-109
    • /
    • 2000
  • The diode characteristics for therapy radiation sensor have been studied by irradiating therapy radiation from the MM22 microtron accelerator. Signal processing has been performed in the pulse mode which can process the signal fast. We have designed integrator, peak detector and synchronization circuit to detect diode signal in the pulse mode for implementation of portal image. We also read the diode signal by A/D board and displayed the peak value with LabView program. Because the quality of portal image obtained by film in the case of therapy radiation is much worse than that of diagnostic film, Digital radiography system by rectifier diode detector was suggested for portal Image.

  • PDF

Treatment for Abnormalities When Raising Arms (발목의 Dorsiflexion과 Plantarflexion의 치료)

  • Shin, Seong-Yoon;Lee, Hyun-Chang
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2017.07a
    • /
    • pp.342-343
    • /
    • 2017
  • 본 논문에서는 만성 발목 불안정성이 있는 환자의 발목 재손상을 예방하고자 한다. 이를 위하여 발목의 안쪽 굽힙(Dorsiflexion)과 바깥쪽 굽힘(Plantarflexion)의 각도를 측정한다. 각도가 일정 범위 내에 있고 고통을 호소하지 않으면 정상으로 간주한다. 하지만 각도가 일정 범위에 못 미치고 고통을 호소하면 이상이 있는 것으로 간주하여 그에 대한 치료법(therapy)을 찾아낸다.

  • PDF

Radiograph-based Diagnostic Methods for Thoracic and Lumbar Spine Malposition in Chuna Manual Therapy Using Biomarkers (단순 방사선 영상기반 바이오마커를 활용한 흉·요추의 추나의학적 변위 진단 방법)

  • Jin-Hyun Lee;Minho Choi;Joong Il Kim;Jun-Su Jang;Tae-Yong Park
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2023
  • Objectives This study aimed to propose biomarkers for diagnosing Chuna manual therapy (CMT) based on X-ray images in the thoracic and lumbar spines. Methods Through a literature review and expert consensus process, diagnostic biomarkers for CMT were selected based on the listing system in thoracic and lumbar radiograph anterior-posterior (AP) and lateral views. Results 1. Diagnostic biomarkers were derived from four points on the outer contour of the vertebral body in the thoracic and lumbar spine radiograph lateral view, enabling the diagnosis of flexion and extension malposition. 2. Additional diagnostic biomarkers were identified in the thoracic and lumbar radiographAP view, utilizing points on the outer contour of the vertebral body. These biomarkers facilitate the diagnosis of lateral bending. Moreover, biomarkers derived from the innermost point of the pedicle contour allow for the diagnosis of rotation malposition. 3. Furthermore, through the biomarkers proposed in this study, all malpositions of the thoracolumbar spines and complex Type I and II malpositions can be diagnosed in CMT. Conclusions The biomarkers reported in this study consist of minimal points to determine the position of the vertebral body, providing the advantage of simplicity while minimizing potential errors during the CMT diagnostic process. Further clinical research and the development of related programs should be pursued to expand the evidence for CMT.