• 제목/요약/키워드: Digital Substation

검색결과 77건 처리시간 0.021초

IED기반 디지털 수배전반의 운전제어 솔루션 설계 (A Study on the Design of Operation and Control Solution for IED based Digital Switchgear Panel)

  • 고윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.141-142
    • /
    • 2006
  • In this paper, DSPOCS(Digital Switchgear Panel Operation and Control Solution) is designed, which is the intelligent inference operation and control solution of substation based on IED. DSPOCS is designed as a scheduled monitoring and control task and a real-time alarm inference task, and is interlinked with BRES in the required case. The intelligent alarm inference task consists of the alarm knowledge generation part and the real-time pattern matching part The alarm knowledge generation part generates automatically alarm knowledge from DB and saves it in alarm KB. On the other hand, the pattern matching part inferences the real-time event by comparing the real-time event information furnished from IEDs of substation with the patterns of the saved alarm knowledge base.

  • PDF

UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계 (UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower)

  • 이동철;배을록;김우정;민병운
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

LAN 기반 디지털 변전소 보호를 위한 동기 샘플링 구조적용 HW/SW 플랫폼 기술 (Synchronized Sampling Structure applied HW/SW platform for LAN-based Digital Substation Protection)

  • 손규정;남경덕;안기성;장태규
    • 전기전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.178-185
    • /
    • 2020
  • 본 논문에서는 미래 LAN 기반 디지털 변전소 보호를 위하여 정밀 시각동기 기반 동기 샘플링 구조를 적용한 계통 구성 IED(Intelligent Electronic Device)의 HW/SW 플랫폼을 제안하였다. 제안한 플랫폼은 전력계통 자동화를 위한 표준인 IEC 61850 프로토콜 및 IED 간 정밀 시각동기를 위한 IEEE 1588 Precision time protocol 통합 소프트웨어가 적용되었으며, Synchronized reference signal을 이용한 IED 간 동기 샘플링 구조를 적용하였다. 이는 미래 IEC 61850 기반 디지털 변전소에 적용될 네트워크 기반 데이터 송수신 환경에서 IED 간 동기 측정된 계전 데이터를 제공하게 함으로써, 네트워크 기반 분산 측정 데이터를 이용한 새로운 보호 및 제어방식을 적용할 수 있는 토대를 제공할 것으로 기대된다. 제시한 플랫폼 기술의 타당성 및 성능을 측정하기 위하여 TMDXIDK572 멀티코어/멀티프로세서 EVM(Evaluation Module)을 기반으로 구현하였으며, 성능 시험 환경을 구성하여 제시한 플랫폼의 시각동기 성능 및 동기 샘플링 기능의 동작을 확인하였다.

RTU 기반 변전소의 IEC 61850 기반 SA 변전소로의 전환에 대한 실증 연구 (A Study on change from an RTU-based substation to IEC 6 1850-based SA substation)

  • 육심복;이성환;김종일
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권4호
    • /
    • pp.436-444
    • /
    • 2018
  • 현재 변전소 자동화를 위해서는 국제 표준인 IEC 61850 통신규약이 사용되어지고 있고, 국내에서도 2007년도부터 시험 적용과 연구개발을 통해 2013년부터 신규 건설되는 변전소는 IEC 61850 기반의 디지털변전소로 준공되어 지고 있다. 하지만 기존 변전 설비들(변압기, T/L GIS, D/L GIS 등)은 그대로 사용하면서 기존 RTU 기반의 변전소 운영 시스템을 IEC 61850 기반의 SA 변전소 운영시스템으로 전환한 사례는 거의 없다. 따라서 기존 변전설비의 IEC 61850 도입은 기존 설비 재사용으로 변전소의 지속가능성을 증대시키고 또한 최신 도입되는 타 변전소와의 상호운영성을 개선하고 기존 변전소를 무인화 운전에 적합한 시스템으로 전환할 수 있는 이점이 있다. 본 논문에서는 기존의 RTU 기반 변전소 운영시스템을 IEC 61850 기반의 현장정보처리반, 이더넷 스위치반, SA 운영시스템을 이용하여 디지털 변전소화한 사례를 소개하고, 패킷 분석 툴인 IEC 61850 클라이언트 인증 프로그램과 Wireshark를 사용하여 IEC 61850 적합성 및 그 타당성을 실증을 통하여 검증하였다.

전력감시 제어시스템을 위한 모터보호용 디지탈 보호계전기 개발 (A development of digital motor protection relay for power supervisory control system)

  • 이성환;우천희;정현호;김정한;김상철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1496-1499
    • /
    • 1997
  • Recently the major requirements have emerged in industrial substation system field. One is the simple arrangement of main power supply equipment and the other is the introduction of highly computer-controlled system for operation, maintenance and protection. This paper deals with the systems including motor-type relay systems, supervisory and control systems, digital type relay protectiion systems.

  • PDF

특정 주파수 추출을 위한 여러 가지 디지털 펄터의 특성 비교 (Characteristic Comparison of Several Digital Filler for Wanted Frequency Component Extraction)

  • 박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.360-362
    • /
    • 2004
  • In this paper, as the preceding research for development of intelligent electronic device for digital based substation automation system, we tried to select the most suitable digital filter by comparison of frequency response characteristic, performance of wanted frequency component extraction.

  • PDF

전력용 변압기용 통합보호제어장치를 위한 디지털 필터에 관한 연구 (A Study on Digital Filter for Intelligent Electronic Device of Power Transformer)

  • 박철원;박재세;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.30-32
    • /
    • 2004
  • In this paper, as the preceding research for development of Intelligent Electronic Device(IED) for digital based substation automation system(SAS), we tried to selection of the most suitable digital filter by comparison of frequency response characteristic. performance of wanted frequency component extraction.

  • PDF

초고압 가스절연개폐기의 베이 컨트롤러 개발 및 성능시험 (The Development and the Performance Test of Bay Controller for the High-Voltage Gas Insulated Switchgear)

  • 우천희;이보인
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.179-184
    • /
    • 2010
  • The digital substation automation system has contributed hugely to increasing the stability of power systems by providing not only protection and control of power systems but diagnostic features alongside them. Digital substation automation systems in the scale of substations consist of integrated operation systems and intelligent electronic devices. The main intelligent electronic devices currently in use are digital protection relays and the bay controllers in Gas insulated switchgears. Proficiently accomplishing the coordination of protection within the power system as a means of ensuring reliability and contriving for the stability of power supply through connection of function, the application of bay controllers is crucial, which collectively manage the protection relay at the bay level in order to achieve both. In this research, the bay controllers to be used in high-voltage Gas insulated switchgear has been localized, and in particular, the logic function and editor required in order to minimize the complicated hardware-like cable connections in the local panel have been developed. In addition, to ensure the strength and reliability of the bay controller hardware developed herein, the type tests from KERI have been successfully completed.

Design of an Algorithm for the Validation of SCL in Digital Substations

  • Jang, B.T.;Alidu, A.;Kim, N.D.
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.89-97
    • /
    • 2017
  • The substation is a critical node in the power network where power is transformed in the power generation, transmission and distribution system. The IEC 61850 is a global standard which proposes efficient substation automation by defining interoperable communication and data modelling techniques. In order to achieve this level of interoperability and automation, the IEC 61850 (Part 6) defines System Configuration description Language (SCL). The SCL is an XML based file format for defining the abstract model of primary and secondary substation equipment, communications systems and also the relationship between them. It enables the interoperable exchange of data during substation engineering by standardizing the description of applications at different stages of the engineering process. To achieve the seamless interoperability, multi-vendor devices are required to adhere completely to the IEC 61850. This paper proposes an efficient algorithm required for verifying the interoperability of multi-vendor devices by checking the adherence of the SCL file to specifications of the standard. Our proposed SCL validation algorithm consists of schema validation and other functionalities including information model validation using UML data model, the Vendor Defined Extension model validation, the User Defined Rule validation and the IED Engineering Table (IET) consistency validation. It also integrates the standard UCAIUG (Utility Communication Architecture International Users Group) Procedure validation for quality assurance testing. Our proposed algorithm is not only flexible and efficient in terms of ensuring interoperable functionality of tested devices, it is also convenient for use by system integrators and test engineers.

Method to Prevent the Malfunction Caused by the Transformer Magnetizing Inrush Current using IEC 61850-based IEDs and Dynamic Performance Test using RTDS Test-bed

  • Kang, Hae-Gweon;Song, Un-Sig;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1104-1111
    • /
    • 2014
  • The digital substations are being built based on the IEC 61850 network. The cooperation and protection of power system are becoming more intelligent and reliable in the environment of digital substation. This paper proposes a novel method to prevent the malfunction caused by the Transformer Magnetizing Inrush Current(TMIC) using the IEC 61850 based data sharing between the IEDs. To protect a main transformer, the current differential protection(87T) and over-current protection(50/51) are used generally. The 87T IED applies to the second harmonic blocking method to prevent the malfunction caused by the TMIC. However, the 50/51 IED may malfunction caused by the TMIC. To solve that problem, the proposed method uses a GOOSE inter-lock signal between two IEDs. The 87T IED transmits a blocking GOOSE signal to the 50/51 IED, when the TMIC is detected. The proposed method can make a cooperation of digital substation protection system more intelligent. To verify the performance of proposed method, this paper performs the real time test using the RTDS (Real Time Digital Simulator) test-bed. Using the RTDS, the power system transients are simulated, and the TMIC is generated. The performance of proposed method is verified in real-time using that actual current signals. The reaction of simulated power system responding to the operation of IEDs can be also confirmed.