• Title/Summary/Keyword: Digital Radiography

Search Result 487, Processing Time 0.03 seconds

Comparison of Direct Digital Radiography and Conventional Film Screen Radiography for Detection of Peritoneal Fluid in Dogs (개에서 복수의 평가에 있어서 필름-증감지 방사선 사진과 디지털 방사선 사진의 비교)

  • Choi, Ho-Jung;O, I-Se;Lee, Ki-Ja;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.18-22
    • /
    • 2012
  • This study was performed to evaluate the sensitivity of conventional film-screen radiography (CFSR) and direct digital radiography (DDR) for detection of various amounts of free peritoneal fluid. Ten adult male healthy beagles were used in this study. Radiographic examinations were performed in the right lateral and ventrodorsal positions. Fluid was injected in increments of 2.0 ml/kg of body weight up to 20.0 ml/kg of body weight. The images of CFSR and DDR were evaluated by two veterinary radiologists for evidence of abdominal fluid without knowledge of injected fluid volume. Data were evaluated by using the receiver operation curve (ROC) analysis and the area under the curve (AUC). There was no significant difference in detection of peritoneal fluid between DDR and CFSR in the ROC analysis. The accuracy of CFSR (0.805) was relatively higher than that of DDR (0.733), based on the ROC analysis and AUC. AUC of CFSR was higher in most injection doses. These results suggest that CFSR is more accurate than DDR for the detecting peritoneal fluid. Therefore, for situation in which digital radiographs are equivocal or small amount of fluid is suspected, other imaging modalities, such as ultrasonography would be helpful for determining the presence of fluids.

Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images (의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • The purpose of this study was tried to evaluate the filling sodium states inside the fuel rod of sodium-cooled fast reactor by digital medical X-ray. We used the diagnostic X-ray generators in digital radiography (DR). This study have found the optimal conditions by changing the effective focal spot size of X-ray tube and post-processing of the DR method with a tungsten edge plate in order to ensure excellent sharpness At this time, the sharpness and resolution were evaluated using the MTF (modulation transfer function). As a result, this study obtained a spatial resolution of 3.871 lp/mm (0.1 MTF), 3.290 lp/mm (0.5 MTF) when implemented the contrast strengthen post-processing in small focal spot. In this research, the result is able to evaluate the level of sodium inside the fuel rod by using the diagnostic X-ray generators in medical digital radiographic images.

A STUDY ON THE ARTIFICIAL INTERPROXIMAL CARIES DETECTION WITH THE DIGITAL RADIOGRAPHY (디지털방사선촬영술을 이용한 인접면 치아우식증 진단에 관한 실험적 연구)

  • Kwon Ki Jeong;Hwang Eui-Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.85-94
    • /
    • 1994
  • The purposes of this study were clinical comparison and evaluation between digital radiography and conventional radiography for the detection of artificial interproximal caries. Four freshly extracted, unrestored posterior teeth were obtained and caries was simulated by drilling semicircled defects with variable size at the interproximal surface of each tooth. The experiments were performed with IBM-PC/32 bit-DX compatible, video camera(VM-S8200, Hitachi Co., Japan), and color monitor(Multisync 3D, NEC, Japan). Sylvia Image Capture Board for the ADC(analog to digital converter) was used, and spatial resolution was 512 × 480 with 256 gray levels. The obtained results were as follows: 1. At the condition of under exposure, the radiographs were superior to the digital images in readability. Also, as the size of the artificial lesion was increased, readability of the radiographs was elevated. 2. The digital images were superior to the radiographs in readability especially under over exsposure. 3. As the exposure time and size of lesion was increased, the gray level of region of interest of the digital image was decreased proportionally. 4. As the F-value of average gray level of region of interest at individual exposure time and size of lesion, gray level of the all lesion sizes was decreased in comparison with that of the normal enamel.

  • PDF

Characterization of digital radiography system (디지탈 X-선 촬영시스템의 영상특성 분석)

  • 김종효;신동익;박광석;민병구;이충웅
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.701-705
    • /
    • 1988
  • We have investigated imaging performance of digital rediography system by measured several imaging properties such as sensitivity characteristic, scatter fraction, modulation transfer function and detective quentum efficiency. The results show that digital rediography system has linear sesitivity to incident energy, excellent scatter elliminaility and high detective quentum efficiency, but poor modulatio transfer function.

  • PDF

Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR) (디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구)

  • Hwang, Jun-Ho;Choi, Ji-An;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.375-383
    • /
    • 2020
  • This study aimed to propose a methodology for quantitatively analyzing problems resulting from the performance and combination of the ionization chamber when using an automatic exposure control (AEC) and to optimize the performance of the digital radiography (DR). In the experimental method, the X-ray quality of the parameters used for the examination of the abdomen and pelvis was evaluated by percentage average error (PAE) and half value layer (HVL). Then, the stability of the radiation output and the image quality were analyzed by calculating the entrance surface dose (ESD) and entropy when the three ionization chambers were combined. As a result, all of the X-ray quality of the digital radiography used in the experiment showed a percentage average error and a half value layer in the normal range. The entrance surface dose increased in proportion to the combination of chambers, and entropy increased in proportion to the combination of ionization chambers except when three chambers were combined. In conclusion, analysis using entrance surface dose and entropy was found to be a useful method for evaluating the performance and combination problems of the ionization chamber, and the optimal performance of the digital radiography can be maintained when two or less ionization chambers are combined.

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

  • Haghanifar, Sina;Moudi, Ehsan;Mesgarani, Abbas;Bijani, Ali;Abbaszadeh, Naghi
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.115-119
    • /
    • 2014
  • Purpose: The aim of this in vitro study was to determine the sensitivity and specificity of cone-beam computed tomography (CBCT) and digital periapical radiography in the detection of mesial root perforations of mandibular molars. Materials and Methods: In this in vitro study, 48 mandibular molars were divided into 4 groups. First, the mesial canals of all the 48 teeth were endodontically prepared. In 2 groups (24 teeth each), the roots were axially perforated in the mesiolingual canal 1-3 mm below the furcation region, penetrating the root surface ("root perforation"). Then, in one of these 2 groups, the mesial canals were filled with gutta-percha and AH26 sealer. Mesial canals in one of the other 2 groups without perforation (control groups) were filled with the same materials. The CBCT and periapical radiographs with 3 different angulations were evaluated by 2 oral and maxillofacial radiologists. The specificity and sensitivity of the two methods were calculated, and P<0.05 was considered significant. Results: The sensitivity and specificity of CBCT scans in the detection of obturated root canal perforations were 79% and 96%, respectively, and in the case of three-angled periapical radiographs, they were 92% and 100%, respectively. In non-obturated root canals, the sensitivity and specificity of CBCT scans in perforation detection were 92% and 100%, respectively, and for three-angled periapical radiographs, they were 50% and 96%, respectively. Conclusion: For perforation detection in filled-root canals, periapical radiography with three different horizontal angulations would be trustworthy, but it is recommended that CBCT be used for perforation detection before obturating root canals.

Automatic Registration of Images for Digital Subtraction Radiography Using Local Correlation (국소적 상관계수를 이용한 자동적 디지털 방사선 영상정합)

  • 이원진;허민석;이삼선;최순철;이재성
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.111-117
    • /
    • 2004
  • Most of digital subtraction methods in dental radiography are based on registration using manual landmarks. We have developed an automatic registration method without using the manual selection of landmarks. By restricting a geometrical matching of images to a region of interest (ROl), we compare the cross-correlation coefficient only between the ROIs. The affine or perspective transform parameters satisfying maximum of cross-correlation between the local regions are searched iteratively by a fast searching strategy. The parameters are searched on the 1/4 scale image coarsely and then, the fine registration is performed on the original scale image. The developed method can match the images corrupted by Gaussian noise with the same accuracy for the images without any transform simulation. The registration accuracy of the perspective method shows a 17% improvement over the manual method. The application of the developed method to radiography of dental implants provides an automatic noise robust registration with high accuracy in almost real time.

Baseline Correction in Computed Radiography Images with 1D Morphological Filter (CR 영상에서 기저선 보정을 위한 1차원 모폴로지컬 필터의 이용에 관한 연구)

  • Kim, Yong-Gwon;Ryu, Yeunchul
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.397-405
    • /
    • 2022
  • Computed radiography (CR) systems, which convert an analog signal recorded on a cassette into a digital image, combine the characteristics of analog and digital imaging systems. Compared to digital radiography (DR) systems, CR systems have presented difficulties in evaluating system performance because of their lower detective quantum efficiency, their lower signal-to-noise ratio (SNR), and lower modulation transfer function (MTF). During the step of energy-storing and reading out, a baseline offset occurs in the edge area and makes low-frequency overestimation. The low-frequency offset component in the line spread function (LSF) critically affects the MTF and other image-analysis or qualification processes. In this study, we developed the method of baseline correction using mathematical morphology to determine the LSF and MTF of CR systems accurately. We presented a baseline correction that used a morphological filter to effectively remove the low-frequency offset from the LSF. We also tried an MTF evaluation of the CR system to demonstrate the effectiveness of the baseline correction. The MTF with a 3-pixel structuring element (SE) fluctuated since it overestimated the low-frequency component. This overestimation led the algorithm to over-compensate in the low-frequency region so that high-frequency components appeared relatively strong. The MTFs with between 11- and 15-pixel SEs showed little variation. Compared to spatial or frequency filtering that eliminated baseline effects in the edge spread function, our algorithm performed better at precisely locating the edge position and the averaged LSF was narrower.

Analysis of the information capacity of digital radiograpy system (디지탈 X-선 촬영 시스템의 정보용량 분석)

  • 김종효;민병구;박광석;한만청
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.564-569
    • /
    • 1990
  • In this paper, the information capacity, the Integrate performance measure of digital radiography system has been quantitatively analyzed. The effect of various factors affecting the information capacity of the digital radiography system in multi-stage detection processes has been considered and analyzed In detail. The results show that the more Information capacity can be obtained with the smaller detector cell area, despite of the decreasing signal to noise ratio due to the reduced number of X-ray photons per detector cell. And also has been Indicated that the Increase of the information capacity may be severely lost by the addition of electric noise in final read-out stage.

  • PDF