• Title/Summary/Keyword: Digital Micro mirror Device

Search Result 16, Processing Time 0.032 seconds

Head Fixed Type Multi-Focus Display System Using Galvano-Scanner and DMD(Digital Micro-Mirror Device) (갈바노 스캐너와 DMD(Digital Micro-mirror Device)를 이용한 두부 고정형 다초점 디스플레이 시스템)

  • Kim, Dong-Wook;Kwon, Yong-Moo;Kim, Sung-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1117-1123
    • /
    • 2009
  • Head fixed type multi-focus display system using Galvano-scanner and DMD(Digital Micro-mirror Device), which is able to perfectly accommodate, can solve eye fatigue due to conflict between convergence eye movement and accommodation action in stereoscopic display. This system is able to accommodate through making convergence point about each view point and offering it in front of observer's pupil by using laser scanning method. In this paper, we analyzed laser scanning method of this multi-focus display system. And multi-focus display system based on this analysis was made, which showed that focus adjustment was possible through video camera. As a result, formation principle of view point of multi-focus system by laser scanning method was verified.

Integral-floating Display with 360 Degree Horizontal Viewing Angle

  • Erdenebat, Munkh-Uchral;Baasantseren, Ganbat;Kim, Nam;Kwon, Ki-Chul;Byeon, Jina;Yoo, Kwan-Hee;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.365-371
    • /
    • 2012
  • A three-dimensional integral-floating display with 360 degree horizontal viewing angle is proposed. A lens array integrates two-dimensional elemental images projected by a digital micro-mirror device, reconstructing three-dimensional images. The three-dimensional images are then relayed to a mirror via double floating lenses. The mirror rotates in synchronization with the digital micro-mirror device to direct the relayed three-dimensional images to corresponding horizontal directions. By combining integral imaging and the rotating mirror scheme, the proposed method displays full-parallax three-dimensional images with 360 degree horizontal viewing angle.

Development of a Contrast Enhancer for MD Projection TV (wwMD 프로젝션 TV의 명암비 향상 액츄에이터 개발)

  • Kim, Jae-Eun;Yun, Gi-Tak;Lee, Jong-Jin;Hong, Sam-Nyol;Ko, Eui-Seok;Ju, Chae-Min;Yang, Sang-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.656-659
    • /
    • 2006
  • MD (DLP, LCoS) Projection TV is appropriate for large screen display with high definition at a relatively low price and thus, has been popular in the digital TV market. In order to realize high resolutions in the DLP projection TV, we successfully developed the Pixel Enhancement Actuator. Furthermore, it is also required that the contrast ratio of projected video signals onto a large screen should be improved. Therefore, we propose a contrast enhancer which adjusts the amount of projected lights by a dynamic aperture and a attached position sensor.

  • PDF

Image Stitching and Seamless Holographic Photo-Lithography for Large-Area Patterning (대면적 리소그래피를 위한 홀로그램 영상의 연결과 연결 영역에서의 간섭무늬 제거)

  • Lee, Joon-Sub;Park, Woo-Jae;Lee, Ji-Whan;Song, Soek-Ho;Lee, Sung-Jin;Kim, Oui-Serg
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • In this study, we propose an image stitching method for large-area holographic photo lithography. In this method, a hologram medium become a hologram mask for lithography. And the mask has information for stitched images. These images are recorded by signal images which are controlled with DMD (digital micro-mirror device), and serial hologram recording is achieved with a motorized linear stage. Using this method, fringe seams appear on the stitching area. To remove these fringe seams, double exposure holographic lithography is tried. Each stitched image is recorded and reconstructed with a different reference beam. The experiments confirm that fringe seams are removed.

An Optical Quenching and Efficiency of Laser for the Virtual Display System (허상 디스플레이에 적용되는 레이저 다이오드의 출력 효율과 파장 변이에 대한 연구)

  • Chi, Yongseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.129-134
    • /
    • 2016
  • This paper studies the high frequency PWM (pulse width modulation) driving technique to increase an optical efficiency and to prevent an optical color quenching of blue laser for head up display on vehicles using digital micro mirror device (DMD) panel and yellow phosphor wheel. The proposed approach adaptively drives the current pulse width modulated signals of high optical power of blue laser to increase the lifetime and to decrease the stem temperature of laser. This method stabilizes the temperature of laser according to the driving environment and the forward current capacity. By the proposed method, the brightness of blue laser is improved by about 37% compared to the continuous waveform current driving method.

Analysis of Correction Displacements of the Projected Distortion Image (투사된 영상에 대한 화면 변위 보정에 관한 연구)

  • Chi, Yongseok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.18-21
    • /
    • 2021
  • This paper analyzes the distortion correction of the in the micro DMD(digital micro mirror device) projector system using 0.25 or less optical throwing distance ratio. The distortion of projected image occurs depending on the performance of the optical lens, the installation location of the projection system, and the tilt of the screen. This study analyzed the physical tilt values influencing of the distortion of projected image, removed the tilt distortion of throwing distance ratio optical lens, and adjusted the distortion image by the simulation of calibration displacements. The results of this study demonstrated within 5% TV distortion reference. Moreover, the correction method reduced the pin-distortion correction of projection system.

Study on Noise Reduction of DLP Front Home Theater Projector (가정용 DLP 프로젝터의 소음 저감에 관한 연구)

  • Jang Dong Seob;Park Chul Min;Park Dae Kyong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.9 s.90
    • /
    • pp.861-867
    • /
    • 2004
  • For the evaluation of acoustic noise of a DLP projector, vibration and sound characteristics of a DLP projector were studied. The acoustic noise of DLP projector could be classified into three categories, that is, the direct noise from a body of rotation, the air-bone noise generated from turbulence or vortex occurred during cooling process and the structural born noise produced by vibrating elements. Cooling fans and color filter wheel which rotates at 9000 rpm are main causes of acoustic noise induced in DLP projector. Since the structure of an optical module in a DLP projector can be excited by the excessive vibration of a color filter wheel, the structural design for anti-vibration should be considered. To make a reduction of overall acoustic noise, the anti-vibration design and the enclosing structure have been studied and applied to a color filter wheel.

Development of Non-contact Image Measuring Technique for Evaluating Micro-relief (미세주름 측정을 위한 비접촉식 영상측정기술의 발전)

  • Kim, Nam-Soo;Kim, Yong-Min
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.31 no.3 s.52
    • /
    • pp.253-257
    • /
    • 2005
  • Assurance of the objectivity and reproducibility is a major key point in wrinkle measurement used for evaluating the degree of skin aging. The measurement of relief is quickly converted to a non-contact method, of which tools or instruments do not come in contact with skin directly, to minimize the artificial effects which influence the shape or depth of the relief. Here, we showed how wrinkle measurement techniques have been changed briefly and compared PRIMOS and replica method in the point of view of measurement principle and features, the former is non-contact fringe projection tool and the latter is contact type of the method.