• Title/Summary/Keyword: Digital Measurement

Search Result 2,099, Processing Time 0.029 seconds

The Implementation of Embedded Web Server System for a Remote Control and Measurement (원격 제어 및 계측을 위한 임베디드 웹 서버 시스템 구현)

  • Lee, Myung-Eui
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.839-845
    • /
    • 2012
  • This paper deals with the design and development of the remote control and measurement systems by Embedded Web Server. The remote control and measurement systems are implemented by Cortex M-3 ARM micro-controller. The user application software for the control and measurement system user, and the firmware software of device drivers for peripherals such as a digital input/output device, AD/DAC(Analog to Digital/Digital to Analog Converter), LCD, and temperature/humidity sensor are developed in Eclipse environment using Codesourcery C, Java script, and HTML. The experimental result of the proposed control and measurement systems implemented in this paper is evaluated via real-time experiments, which works well as designed.

On the measurement of characteristics of antennas for indoor digital TV (실내 디지털 TV용 안테나 특성 측정에 관하여)

  • Park, Jin-Taek;Lee, Jong-Ig;Yeo, Junho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2345-2350
    • /
    • 2014
  • In this paper, measurement methods for the characteristics of antennas for indoor digital TV (DTV), having 75-ohm port impedance, are introduced. Reference impedance of typical radio frequency (or microwave) systems and measurement equipments is 50 ohm. However, the reference impedance of antennas for indoor DTV is 75 ohm, and the characteristics of the antennas cannot be measured directly using the measurement equipments. Measurement methods, using test equipments with reference impedance of 50 ohm, for the characteristics(impedance, radiation patterns, and gain) of antennas designed to fit for 75 ohm port are introduced.

On the measurement of characteristics of planar antennas for indoor digital TV (실내 디지털 TV용 평면 안테나 특성 측정에 관하여)

  • Lee, Jong-Ig;Yeo, Junho;Kim, Soo-Min;Yang, Myung-Kyu;Eun, Jang-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.45-46
    • /
    • 2014
  • In this paper, measurement methods for the characteristics of antennas for indoor digital TV (DTV), having 75-ohm port impedance, are introduced. Reference impedance of typical radio frequency (or microwave) systems and measurement equipments is 50 ohm. However, the reference impedance of antennas for indoor DTV is 75 ohm, and the characteristics of the antennas cannot be measured directly using the measurement equipments. Measurement methods, using test equipments with reference impedance of 50 ohm, for the characteristics(impedance, radiation patterns, and gains) of antennas designed to fit for 75 ohm port are introduced.

  • PDF

The Measurement of Nano-grating by Scanning Probe Microscopy Using Digital PID Control (Digital PID Control을 적용한 Scanning Probe Microscopy의 Nano-grating 측정)

  • Park, Gyeong-Deok;Ji, Won-Su;Kim, Dae-Chan;Jang, Dong-Hun;O, Beom-Hwan;Park, Se-Geun;Lee, Il-Hang;Lee, Seung-Geol
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.07a
    • /
    • pp.185-186
    • /
    • 2008
  • In this paper, the nano-grating was measured by Scanning Probe Microscopy (SPM) system using digital Proportion, Integration and Derivative (PID) control. Through this measurement, we could confirm the improvement of the vertical resolution compared with analog Proportion and Integration (PI) control method.

  • PDF

Development of Code-Domain Power module for CDMA signal (CDMA 신호의 Code Domain Power 모듈 개발)

  • Lee, Young Kyo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 2008
  • This paper describes the measurements that provide a characterization of the code-domain channels of a CDMA base station transmitter. One of the measurements, called code-domain power(CDP), provides the distribution of power in the code domain channels. This measurement can be used to verify that the various channels are at expected power levels and to determine when one code channel is leaking energy into the other code channels. We develop module of CDP measurement in the CDMA system.

A Study on Service Quality Measurement of Digital Libraries with DL-SQI Model (DL-SQI 모형을 이용한 디지털도서관의 서비스 품질측정에 관한 연구)

  • Hwang, Jae-Young;Lee, Eung-Bong
    • Journal of Information Management
    • /
    • v.41 no.3
    • /
    • pp.45-66
    • /
    • 2010
  • The purpose of this study is to develop service quality measurement model(DL-SQI model) which are able to measure objectively service quality of digital libraries in Korea and to measure user perceived service quality performance with DL-SQI model. This study also investigates the influence of service quality on customer satisfaction and customer loyalty. Before measurement, two principal rules and indicator formula were made to measure the service quality. Finally service quality of three digital libraries selected as samples was measured and analyzed in various points of view. It was developed a DL-SQI Consequences Model and testified it through path analysis using structural equation model.

2D Image Construction from Low Resolution Response of a New Non-invasive Measurement for Medical Application

  • Hieda, Ichiro;Nam, Ki-Chang
    • ETRI Journal
    • /
    • v.27 no.4
    • /
    • pp.385-393
    • /
    • 2005
  • This paper presents an application of digital signal processing to data acquired by the radio imaging method (RIM) that was adopted to measure moisture distribution inside the human body. RIM was originally developed for the mining industry; we are applying the method to a biomedical measurement because of its simplicity, economy, and safety. When a two-dimensional image was constructed from the measured data, the method provided insufficient resolution because the wavelength of the measurement medium, a weak electromagnetic wave in a VHF band, was longer than human tissues. We built and measured a phantom, a model simulating the human body, consisting of two water tanks representing large internal organs. A digital equalizer was applied to the measured values as a weight function, and images were reconstructed that corresponded to the original shape of the two water tanks. As a result, a two-dimensional image containing two individual peaks corresponding to the original two small water tanks was constructed. The result suggests the method was applicable to biomedical measurement by the assistance of digital signal processing. This technique may be applicable to home-based medical care and other situations in which safety, simplicity, and economy are important.

  • PDF

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Manikin Model Study on Reproducibility and Accuracy of Maxillofacial Measurements Determined by Stereocamera: Comparative Study of Direct Anthropometry, Digitizer and Stereophotogrammetery (스테레오 카메라를 이용한 안면부 측정의 재현성과 정확도에 대한 마네킨을 이용한 연구: 직접 인체계측, Digitizer, Stereophotogrammetry의 비교 연구)

  • Jeoung, Youn-Wook;Yang, Ji-Woong;Chung, Kwang;Kook, Min-Suk;Oh, Hee-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.17-25
    • /
    • 2012
  • Purpose: Recently, a three dimensional approach to hard and soft tissues of the maxillofacial area has been widely used. This study was to evaluate the reproducibility and accuracy of a stereocamera compared to actual measurement methods using a digital caliper and digitizer. Methods: The stereoscopies of 7 head dummies with different sizes and shapes were obtained using a Di3D system (Dimensional Imaging, Glasgow, UK) after marking reference points on facial areas. From the obtained stereoscopy, 10 measurements representing the width, height and depth of each of the facial sections of the dummy were measured twice using a three dimensional reverse engineering software program (RapidForm$^{TM}$ 2006, Inus, Seoul, Korea). The x, y, and z coordinates of each of the three dimensional measurements were obtained and distances between two points were calculated. All procedures were repeated twice. The actual measurement method was performed twice, directly on dummies, using a digital caliper and values were compared with the previously determined values. Results: The results were as follows. In the ANOVA analysis, there were no significant statistical differences among the three measurement methods. In the Bonferroni analysis, with adjustments applied for multiple comparisons, there was no difference between actual measurement methods using a digitizer and a digital caliper. However, there was some difference between using a stereocamera and actual measurement methods using a digitizer and a digital caliper in values of $Ex_{Rt}-Ex_{Lt}$, $En_{Rt}-En_{Lt}$, $Ala_{Rt}-Ala_{Lt}$, $Ch_{Rt}-Ch_{Lt}$, G-Pg', $Ala_{Rt}$-Prn, $Ala_{Rt}$-Prn. The mean value for technical error in measurement (TEM) in Di3D (0.98 mm) was slightly higher than for a digital caliper (0.17 mm) and a digitizer (0.30 mm). In an intraclass correlation coefficient (ICC) there were no significant differences among the three measurement methods, but the Di3D system with the stereocamera showed relatively lower reproducibility compared to actual measurement methods using a digitizer and a digital caliper. Conclusion: These results indicate that some complementary measures may be needed to improve accuracy and reproducibility in the Di3D system with stereocamera.

The Development of Integrated Mobile Measurement System for Terrestrial DMB (지상파 DMB를 위한 통합 이동 측정 시스템 개발)

  • Kim Sang-Hun;Yim Zung-Kon;Chae Young-Seok;Kim Man-Sik
    • Journal of Broadcast Engineering
    • /
    • v.9 no.4 s.25
    • /
    • pp.411-423
    • /
    • 2004
  • In Korea, Eureka-147 DAB (Digital Audio Broadcasting) temporarily decided as the standard system for digital audio broadcasting was evolved into DMB (Digital Multimedia Broadcasting) to complement the technical vulnerability in mobile reception of terrestrial DTV. According to introducing video service in T-DMB (Terrestrial DMB), 'Terrestrial DMB Experimental Broadcasting for Video Service', a national project of the MIC (Ministry of Information and Communication), was done for verifying the possibility of video service via T-DMB. The main objective of the project is computing the effective field strength and coverage for making a plan to build T-DMB broadcasting network and developing transmitting and receiving equipment. In case of digital broadcasting, it is absolutely essential to measure BER (Bit Error Rate) and electric field strength in order to evaluate coverage and quality of received signal. In this paper, we implement an integrated mobile measurement system for T-DMB. For this purpose, we propose efficient data structure and algorithm for BER measurement. By adding GPS (Global Positioning System) and electric field strength measurement parts into BER measurement part, we complete the integrated mobile measurement system, and then verify it by experiments and field tests. The developed system was used in a national project, 'Terrestrial DMB Experimental Broadcasting for Video Service' and measurement results will be used as fundamental data for building T-DMB broadcasting network.