• 제목/요약/키워드: Digital Measurement

검색결과 2,099건 처리시간 0.031초

건축물(建築物) Elevator Cage의 진동(振動) 측정(測定) (The Vibration measurement which occurs from the Elevator Cage of the Building)

  • 전의식;조병후
    • 한국디지털건축인테리어학회논문집
    • /
    • 제4권2호
    • /
    • pp.52-59
    • /
    • 2004
  • The interest about noise and vibration which occurs in buildings is increasing by a living level elevation recently. Particularly, the vibration which occurs from the elevator cage of the building is possibility of damage to the users of the building continuously. So, the purpose of this study is to suggest of measuring results to the vibration that occurs from the elevator cage and propose the countermeasure of it.

  • PDF

Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won;Lee, Minho;Kang, Min Soo
    • International journal of advanced smart convergence
    • /
    • 제8권4호
    • /
    • pp.154-160
    • /
    • 2019
  • In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

정부출연 연구기관의 지식관리 성과 측정모형 개발을 위한 탐색적 연구 (An Exploratory Study of the Development of a Performance Measurement Model for Knowledge Management for use by Government Sponsored Research Institutes)

  • 정택영;정해용;최광돈
    • 디지털융복합연구
    • /
    • 제7권3호
    • /
    • pp.61-74
    • /
    • 2009
  • This research reviewed previous research related to Performance Measurement Models of Knowledge Management (PMMKM) in order to integrate their findings with more recent research and construct a new PMMKM. This new hypothetical PMMKM consists of an input sector, a process sector, an outcome sector, and an infrastructure sector. Each sector has three measurement items with the exception of the infrastructure sector which has two. Empirical analyses testing the overall performance model validity of the hypothetical PMMKM were favorable. However, it show be noted that the "share process" and "utilization process" items in the process sector merged into one single item. The same is true with the "individual outcome" and "organization outcome" items in the outcome sector found one single item. The study's results reveal three implications with respect to performance. First, there are derived integrated performance measurement sectors and items based on overall management process of knowledge management, which can be practically applied to the government related research entities. This became apparent after extensive review or previous theoretical studies related to the public sector and private sector. Second, weighted performance measurement of knowledge management using AHP (Analytic Hierarchy Process) Analysis makes it possible to propose PMMKM in government sponsored research institutes. Finally, measuring performance to management knowledge, as shown in this study, will prove useful for inside and outside experts who propose specific guidelines and methodologies for Knowledge management at government sponsored research institutes.

  • PDF

딥러닝 기반 포즈인식을 이용한 체력측정 시스템 (Fitness Measurement system using deep learning-based pose recognition)

  • 김형균;홍호표;김용호
    • 디지털융복합연구
    • /
    • 제18권12호
    • /
    • pp.97-103
    • /
    • 2020
  • 제안한 시스템은 AI 체력측정 파트와 AI 체력관리 파트 2가지 부분이 연계성을 가지고 구성되어 있다. AI 체력측정 파트에서 딥러닝 기반의 포즈인식을 통해 체력측정에 대한 가이드와 측정값의 정확한 연산을 수행한다. 이 측정값을 기반으로 AI 체력관리 파트에서는 개인 맞춤형 운동프로그램을 설계해 전용 스마트 어플리케이션에 제공한다. 측정자세 가이드를 위해 웹캠을 통해 측정대상자의 자세를 촬영해 골격선을 추출한다. 다음으로 학습된 준비자세의 골격선과 추출된 골격선을 비교해 정상 유무를 판단하고, 정상자세 유지를 위한 음성안내를 실시한다.

특이값 분해를 이용한 치수측정 기반 디지털 트윈 알고리즘 경량화 (Lightweight Algorithm for Digital Twin based on Diameter Measurement using Singular-Value-Decomposition)

  • 이승민;박대진
    • 대한임베디드공학회논문지
    • /
    • 제18권3호
    • /
    • pp.117-124
    • /
    • 2023
  • In the machine vision inspection equipment, diameter measurement is important process in inspection of cylindrical object. However, machine vision inspection equipment requires complex algorithm processing such as camera distortion correction and perspective distortion correction, and the increase in processing time and cost required for precise diameter measurement. In this paper, we proposed the algorithm for diameter measurement of cylindrical object using the laser displacement sensor. In order to fit circle for given four input outer points, grid search algorithms using root-mean-square error and mean-absolute error are applied and compared. To solve the limitations of the grid search algorithm, we finally apply the singular-value-decomposition based circle fitting algorithm. In order to compare the performance of the algorithms, we generated the pseudo data of the outer points of the cylindrical object and applied each algorithm. As a result of the experiment, the grid search using root-mean-square error confirmed stable measurement results, but it was confirmed that real-time processing was difficult as the execution time was 10.8059 second. The execution time of mean-absolute error algorithm was greatly improved as 0.3639 second, but there was no weight according to the distance, so the result of algorithm is abnormal. On the other hand, the singular-value-decomposition method was not affected by the grid and could not only obtain precise detection results, but also confirmed a very good execution time of 0.6 millisecond.

디지털 독서 및 정보 리터러시 평가 문항 분석을 통한 독서 및 정보 서비스의 방향 탐색 - PIAAC와 PISA를 중심으로 - (A Study on the Direction of Reading and Information Service through Analysis of Digital Reading and Information Literacy Competencies Evaluation Items: Focusing on PIAAC and PISA)

  • 박주현
    • 한국문헌정보학회지
    • /
    • 제52권3호
    • /
    • pp.61-89
    • /
    • 2018
  • 본 연구의 목적은 국제 성인 역량 평가(PIAAC)와 국제 학업성취도 평가(PISA)에서 측정된 디지털 독서 리터러시 및 디지털 정보 리터러시 문항의 측정 내용과 방법을 살펴보고 공공도서관의 사서와 초 중등학교의 사서교사가 독서 및 정보 서비스를 제공하는 데에 필요한 시사점을 도출하는 데 있다. 디지털 독서 리터러시나 디지털 정보 리터러시 측정 문항을 해결하기 위하여 응답자는 인지 전략과 더불어 ICT 기술 역량이 공통적으로 필요하였다. 다만 디지털 독서 리터러시 측정 문항에서는 텍스트를 종합적으로 이해하고 비판적으로 사고하는 능력이 강조되었으며 디지털 정보 리터러시 측정 문항에서는 ICT 활용 능력과 항해(navigation) 능력 및 검색된 텍스트를 읽을 것인지를 평가하는 능력이 강조되었다. 사서나 사서교사들은 이용자들의 독서를 더욱 권장할 필요가 있으며, 특정한 집단의 성취결과나 특성을 반영하여 맞춤형 역량 향상 프로그램을 제공할 필요가 있다. 또한 자료 검색시스템과 한국십진분류법에 대한 이해와 활용이 가능하도록 도서관 환경을 정비하고 개발할 필요가 있다.

디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석 (Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer)

  • 장우남;이경보;염준우;황병용
    • The Journal of Korean Physical Therapy
    • /
    • 제25권4호
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.