• Title/Summary/Keyword: Digital Measurement

Search Result 2,099, Processing Time 0.031 seconds

Design and Measurement of Active Phased Array Radar Digital Receiver (능동 위상 배열 레이더의 디지털 수신기 제작 및 측정)

  • Kim, Tae-Hwan;Lee, Sung-Ju;Lee, Dong-Hwi;Hong, Yun-Seok;Cho, Choon-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.371-379
    • /
    • 2011
  • Active phased array antenna structure is used for modern multi-function radars. To search targets in high clutter environment, the radar receiver needs high dynamic range performance. Though active phased array antenna structure lead to increase of SNR, the SFDR is not increased. In this paper, high SFDR receiver of X-band active phased array radar was designed and manufactured. One channel digital receiver is connected to 32 T/R modules and one PCB assembly is composed to 2 channel digital receivers with RF part, ADC part, LO distribution part and digital down conversion part. A commercial FIFO board was used for digital receiver measurement about major performance in digital output signal condition. The measured digital receiver gain and SFDR is 33 dB and more than 81 dBc each.

Damage Measurement for Molybdenum Thin Film Using Reflection-Type Digital Holography (반사형 디지털 홀로그래피를 이용한 Molybdenum 박막의 손상 측정)

  • Kim, Kyeong-Suk;Jung, Hyun-Il;Shin, Ju-Yeop;Ma, Hye-Joon;Kwon, Ik-Hwan;Yang, Seung-Pill;Hong, Chung-Ki;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2015
  • In the fabrication of electronic circuits used in electronic products, molybdenum thin films are deposited on semiconductors to prevent oxidation. During the deposition, the presence of a particle or dust at the interface between the thin film and substrate causes the decrease of adhesion, performance, and life cycle. In this study, a damage measurement targeting two kinds of glass substrate, with and without particles, was performed in order to measure the change in the molybdenum thin film deposition area in the presence of a particle. Clean and dirty molybdenum thin film specimens were fabricated and directly deposited on a substrate using the sputtering method, and a reflection-type digital holographic interferometer was configured for measuring the damage. Reflection-type digital holography has several advantages; e.g., the configuration of the interferometer is simple, the measurement range can be varied depending on the magnification of a microscopic lens, and the measuring time is short. The results confirm that reflection-type digital holography is useful for the measurement of the damage and defects of thin films.

3D imaging and 3D display based on digital holography

  • Matoba, Osamu
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.10a
    • /
    • pp.133-134
    • /
    • 2009
  • We have presented our approach to build a 3D display system based on digital holography. For wide viewing angle, we have presented several techniques such as measurement, time-sharing display, and coherent amplification. These techniques can advance the wavefront 3D display system to next stage.

  • PDF

A Study on 3D-Coordinate Extraction of Structure by Using The Digital Camera (디지털 카메라를 이용한 구조물의 3차원 좌표 추출에 관한 연구)

  • Kim, Kam-Lae;Kim, Hak-Joon;Park, Yong
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.219-224
    • /
    • 2003
  • Recently, the number of the use of Digital Photogrammetry is increasing, the Digital Photogrammetry is used for the acquisition of images, remote sensing and three dimension location. Especially, the three dimension location is more activated to use digital camera for the Digital Photogrammetry. The reason is that it is cheap and easy to use and also it has high confidence. Using non-metric digital camera not metric camera, in this research, to get images and apply the images to the Direct Liner Transformation which is one of the techniques in Digital Photogrammetry to get three dimensional location of a point. Ⅰ programmed the procedure with Visual C++ to get the position of points speedly and I tested possibility whether it can analyze the displacement and the existence of structure with measurement system which is structured by a inexpensive non-metric digital camera.

  • PDF

Improvement of the Accuracy and Conveniency in Automated Strain Measurement through High-Resolution Image Processing (고해상도 화상처리를 통한 자동 변형률 측정의 정확도와 편의성 개선)

  • Kim, H.J.;Choi, S.C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.06a
    • /
    • pp.34-39
    • /
    • 2006
  • An automated surface-strain measurement system, named ASIAS, was developed by using the image processing and stereo vision techniques in the previous studies by the corresponding author and his coworkers. This system has been upgraded mainly to improve the accuracy through image enhancement, sub-pixel measurement, surface smoothing, etc., since the first version was released. The present study has still more improved the convenience of users as well as the accuracy of measurement by processing high resolution images 8 mega pixels or more which can be easily obtained from a portable digital steal camera. It is proved that high resolution image processing greatly decreases the measurement error and gives strain data without considerable deterioration of accuracy even when the deformed grids to be measured and the master grids for camera calibration are captured together in the same image, making the whole process of strain measurement much simpler.

  • PDF

Evaluation of the Model Accuracy according to Three Types of Dental Scanner (세 가지 방식의 스캐너 종류에 따른 모형 정확도 평가)

  • Lee, Jae-Jun;Park, Jin-Young;Bae, So-Yeon;Jeon, Jin-Hun;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.226-231
    • /
    • 2015
  • The purpose of this study was to evaluate the accuracy of model according to three types of dental scanner. A maxillary acrylic model was prepared and duplicated 10 times by silicone impression materials. Corresponding working casts were formed from scannable stone and got a 3-dimensional digital models using three different scanners. The distance of each measurement region was measured using vernier calipers and the respective program. One-way ANOVA and the Tukey honestly significant difference post hoc test (${\alpha}=0.05$) was performed using IBM SPSS Statistics 21.0. Overall, the stone cast is smaller than the digital models in measurement distance. And measuring point value of laser scanner showed the most similar values and measurement points value of digital vernier calipers. Digital model of white light scanner showed similar values in the measurement points value of the blue light scanner. In conclusion, the laser scanner showed the best accuracy among the three types of dental scanner. However, the difference between the digital models and the stone cast can be accommodated in making prostheses. Thereby, three types of dental scanner are available in a clinically acceptable range.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF

Measurement of digital television loudness (디지털 텔레비전 라우드니스 측정)

  • Lee, SangWoon;Kim, Cheong Ghil
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.4
    • /
    • pp.141-145
    • /
    • 2015
  • The dynamic range of the loudness after digitalization of television broadcasting is enlarged, and the loudness difference between the broadcast channel and between the programs within the same channel is expanded. This was subjected to interfere with the television viewer's comfort. In order to improve these problems international standards for the loudness normalization was established in ITU, Europe, USA and Japan. This regulation was introduced to Korea also as technical regulation, and this will apply the broadcast service in June 2016. In this paper, ahead of the introduction of digital television technology based on loudness measurement for the major television channel and to present the results of the comparison of technical standard.

Study on Digital Holography with Conjugated Hologram (복소공액 홀로그램을 이용한 디지털 홀로그래피 연구)

  • Shin, Sang-Hoon;Kim, Doo-Cheol;Yu, Young-Hun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.146-150
    • /
    • 2010
  • In this paper we have applied phase conjugated holographyto DHM (digital holography microscopy) to remove phase aberration and noise. Generally,digital holographyincludes the phase information of the object, phase aberration terms introduced by the measurement system and noise terms (DC term and twin images). These aberrations and noise terms decrease the quality of the reconstructed phase image. We could obtain a conjugated hologram which includes only phase information of object. Experimentally we show that distortion of image and aberration of phase in a measurement system are removed using the conjugation hologram.