DOI QR코드

DOI QR Code

Study on Digital Holography with Conjugated Hologram

복소공액 홀로그램을 이용한 디지털 홀로그래피 연구

  • Received : 2010.05.04
  • Accepted : 2010.07.27
  • Published : 2010.08.25

Abstract

In this paper we have applied phase conjugated holographyto DHM (digital holography microscopy) to remove phase aberration and noise. Generally,digital holographyincludes the phase information of the object, phase aberration terms introduced by the measurement system and noise terms (DC term and twin images). These aberrations and noise terms decrease the quality of the reconstructed phase image. We could obtain a conjugated hologram which includes only phase information of object. Experimentally we show that distortion of image and aberration of phase in a measurement system are removed using the conjugation hologram.

디지털 홀로그래피에서 재생상을 재생할때 복소공액 홀로그램을 도입하여 위상 왜곡과 잡음이 제거된 재생 영상을 얻는 방법에 대하여 연구하였다. 일반적으로 디지털 홀로그램은 시료의 위상 정보 외에 위상 정보에 겹쳐져 있어 잡음으로 작용하는 허상, DC항 뿐만 아니라 측정 시스템의 위상 왜곡 현상도 모두 포함되어 기록된다. 기록된 홀로그램에서 시료의 위상 정보만을 분리하여 이를 재생하면 질 좋은 위상 재생상을 얻을 수 있다. 본 연구에서는 복소공액 홀로그램을 이용하면 off-axis 및 in-line 홀로그래피에서 위상왜곡과 측정시스템이 가지고 있는 잡음을 제거 할 수 있음을 실험적으로 확인하였다.

Keywords

References

  1. J. W. Goodman and R. W. Lawrence, “Digital image formation from electronically detected holograms,” Appl. Phys. Lett. 11, 77-79 (1967). https://doi.org/10.1063/1.1755043
  2. M. A. Kronrod, N. S. Merzlyakov, and L. P. Yaroslavski, “Reconstruction of hologram with a computer,” Sov. Phys. Tech. 17, 434-444 (1972).
  3. G. K. Wernicke, O. Kruschke, N. Demoli, and H. Gruber, “Investigation of micro-opto-electro-mechanical components with a holographic microscopic interferometer,” Proc. SPIE 3396, 238-243 (1998). https://doi.org/10.1117/12.301528
  4. L. Xu, X. Peng, J. Miao, and K. Asundi, “Studies of digital microscopic with application to microstructure testing,” Appl. Opt. 40, 5046-5051 (2001). https://doi.org/10.1364/AO.40.005046
  5. H. Cho, D. Kim, Y. Yu, W. Jung, and S. Shin, “3-dimensional measurement using digital holographic microscope and phase unwrapping,” Hankook Kwanghak Hoeji (Korean J. Opt. Photon.) 17, 329-334 (2006). https://doi.org/10.3807/KJOP.2006.17.4.329
  6. S. Kim, H. Lee, and J. Son, “Recording of larger object by using two confocal lenses in digital holography,” Hankook Kwanghak Hoeji (Korean J. Opt. Photon.) 14, 244-248 (2003). https://doi.org/10.3807/KJOP.2003.14.3.244
  7. U. Schnars, “Direct phase determination in hologram interferometry with use of digitally recorded holograms,” J. Opt. Soc. Am. A11, 2011-2015 (1994).
  8. C. Wagneer, S. Seebacher, W. Osten, and W. Juptner, “Digital recording and numerical reconstruction of lensless Fourier holograms in optical metrology,” Appl. Opt. 38, 4812-4820 (1999). https://doi.org/10.1364/AO.38.004812
  9. Y. Takaki and H. Ohzu, “Fast numerical reconstruction technique for high resolution hybrid holographic microscopy,” Appl. Opt. 38, 2204-2055 (1999). https://doi.org/10.1364/AO.38.002204
  10. L. Xu, J. Miao, and A. Asundi, “Properties of digital holography based on in-line configuration,” Opt. Eng. 39, 3214-3219 (1999). https://doi.org/10.1117/1.1327503
  11. T. Colomb, E. Cuche, F. Charriere, J. Kuhn, N. Aspert, F. Montfort, P. Marquet, and C. Depeursinge, “Automatic procedure for aberration compensation in digital holographic microscopy and applications to specimen shape compensation,” Appl. Opt. 45, 851-863 (2006). https://doi.org/10.1364/AO.45.000851
  12. E. Cuche, P. Marquet, C. Depeursinge, “Simultaneous amplitude and quantitative phase-contrast microscopy by numerical reconstruction of Fresnel off-axis holograms,” Appl. Opt. 38, 6994-7001 (1999). https://doi.org/10.1364/AO.38.006994
  13. T. Colomb, J. Kuhn, F. Charriere, and C. Depeursinge, “Total aberrations compensation in digital holographic microscopy with a reference conjugated hologram,” Opt. Exp. 14, 4300-4304 (2006). https://doi.org/10.1364/OE.14.004300
  14. H. Cho, W. Jang, J. Shon, D. Kim, S. Shin, and Y. Yu, “Twin-image elimination in an in-line digital holographic microscope,” J. Korean Phys. Soc. 52, 1031-1035 (2008). https://doi.org/10.3938/jkps.52.1031
  15. H. Cho, J. Woo, D. Kim, S. Shin, and Y. Yu, “DC suppression in in-line digital holographic microscopes on the basis of an intensity-averaging method using variable pixel numbers,” Opt. & Laser Technology 41, 741-745 (2009) https://doi.org/10.1016/j.optlastec.2009.01.001

Cited by

  1. Study on Error Reduction in Dual Wavelength Digital Holography Using Modified Fine Map vol.22, pp.3, 2011, https://doi.org/10.3807/KJOP.2011.22.3.129
  2. Study on Digital Holography with Self-Reference Hologram vol.22, pp.5, 2011, https://doi.org/10.3807/KJOP.2011.22.5.214
  3. Dual-wavelength Digital Holography Microscope for BGA Measurement Using Partial Coherence Sources vol.15, pp.4, 2011, https://doi.org/10.3807/JOSK.2011.15.4.352