• Title/Summary/Keyword: Digital Master Model

Search Result 63, Processing Time 0.026 seconds

Evaluation of validity of polyurethane model fabricated by intra-oral scanning method (구강 내 스캐닝 방법에 의해 제작된 폴리우레탄 모형의 정확도 평가)

  • Kim, Won-Tae;Lee, Byung-Ki;Hyun, Joung-Ku;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.36 no.2
    • /
    • pp.91-96
    • /
    • 2014
  • Purpose: The purpose of this study was evaluate the validity of polyurethane model fabricated by intra oral scanning method. Methods: Ten sam cases of stone models were manufactured from master model, and polyurethane models were made with the intra oral scanning and CNC milling method. One examiner individually measured 6 distances(intercanine distance, intermolar distance, two dental arch lengths(right, left) and two diagonal of dental arch lengths(right, left) on the stone models and the polyurethane models. The Mann-Whitney U test(${\alpha}$=0.05) were used for statistical analysis. Results: The mean difference between measurements made directly on the stone models and those made on the polyurethane models was 0.31-0.38mm. No statistically differences between the two groups were founded 4 distances(p>0.05), but 2 distances were statistically significant(p<0.05). Conclusion: Stone models showed larger than polyurethane models fabricated by intra oral scanning method.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis (세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석)

  • Kang, Seen-young;Park, Jin-Young;Kim, Dong-Yeon;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

Digital Twin Model Design And Implementation Using UBS Process Data (UBS공정 데이터를 활용한 디지털트윈 모델 설계 및 구현)

  • Park, Seon-Hui;Bae, Jong-Hwan;Ko, Ho-Jeong
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.3
    • /
    • pp.63-68
    • /
    • 2022
  • Due to COVID-19, many paradigm shifts in existing manufacturing facilities and the expansion of non-face-to-face services are accelerating worldwide. A representative technology is digital twin technology. Such digital twin technology, which existed only conceptually in the past, has recently become feasible with the construction of a 5G-based network. Accordingly, this paper designed and implemented a part of the USB process to enable digital twins based on OPC UA communication, which is a standard interlocking structure, between real object objects and virtual reality-based USB process in accordance with this paradigm change. By reflecting the physical characteristics of real objects together, it is possible to simulate real-time synchronization of these with real objects. In the future, this can be applied to various industrial fields, and it is expected that it will be possible to reduce costs for decision-making and prevent dangerous accidents.

Real-Time Implementation of the Navigation Parameter Extraction from the Aerial Image Sequence (항공영상을 이용한 항법변수 추출 알고리듬의 실시간 구현)

  • 박인준;신상윤;전동욱;김관석;오영석;이민규;김인철;박래홍;이상욱
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.489-492
    • /
    • 2000
  • 본 논문에서는 영상 항법 변수 추출 알고리듬의 실시간 구현에 관해 연구하였다. 영상 항법 변수 추출 알고리듬은 이전 위치를 기준으로 현재 위치를 추정해내는 상대위치 추정 알고리듬과 상대위치 추정에 의해 누적되는 오차를 보정하기 위한 절대위치 보정 알고리듬으로 구성된다. 절대위치 보정 알고리듬은 고해상도 영상과 IRS (Indian Remote Sensing) 위성영상을 기준영상으로 이용하는 방법 및 DEM (Digital Elevation Model) 을 이용하는 방법으로 구성된다. 하이브리드 영상 항법 변수 추출 알고리듬을 실시간으로 구현하기 위해 MVP (Multimedia Video Processor)로 명명된 TMS320C80 DSP (Digital Signal Processor) 칩을 사용하였다. 구현된 시스템은 MVP의 부동 소수점 프로세서인 MP (Master Processor) 를 고정 소수점 프로세서인 PP (Parallel Processor) 를 제어하거나 삼각함수 계산과 같은 부동 소수점 함수를 계산하는데 사용하였고, 대부분의 연산은 PP를 사용하여 수행하였다. 처리시간이 많이 필요한 모듈에 대해서는 고속 알고리듬을 개발하였고, 4개의 PP를 효율적으로 사용하기 위한 영상분할 방법에 대해 제안하였다. 비행체에서 캡코더를 이용해 촬영한 연속 항공 영상과 비행체의 자세정보를 입력으로 실시간 시뮬레이션 하였다. 실험결과는 하이브리드 항법 변수 추출 알고리듬의 실시간 구현이 효과적으로 구현되었음을 나타내고 있다.

  • PDF

A study on marginal fit of the ceramic-based hybrid resin restoration for dental CAD/CAM systems (치과용 CAD/CAM 전용 세라믹기반 하이브리드 레진 수복물의 변연 적합 연구)

  • Jeong, Chang-Seop;Park, Jong-Kyoung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.228-233
    • /
    • 2020
  • Purpose: This study aimed to assess and compare the marginal fit of ceramic-based hybrid resin restoration (HYB) and zirconia restoration (ZIR) for dental computer-aided design/computer-aided manufacturing systems. Methods: A stainless steel master model was produced. The impression was first made with silicone, and then stone working models were produced. A total of twenty restorations were fabricated with two different materials: ZIR and HYB. The silicone film thickness of the marginal gap was measured using a digital microscope; digital photos were taken at a magnification of ×160, and then analyzed using a measurement software. The values of the result were evaluated with the independent-sample t-test (α=0.05). All statistical analyses were performed with a statistical software. Results: The mean values for the marginal gap was 37.14±2.96 ㎛ for HYB, compared with 40.37±5.26 ㎛ for ZIR. No significant difference was found between ZIR and HYB (p=0.107). Conclusion: As a result, the marginal fit of the restoration fabricated using the hybrid resin was better than that of the restoration fabricated using zirconia. Also, the marginal fit of all groups was below the clinical acceptable range of 120 ㎛. Thus, HYB for dental CAD/CAM system in this study is expected to be suitable for clinical use in dentistry.

Comparison of different digital shade selection methodologies in terms of accuracy

  • Nursen Sahin;Cagri Ural
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.38-47
    • /
    • 2024
  • PURPOSE. This study aims to evaluate the accuracy of different shade selection techniques and determine the matching success of crown restorations fabricated using digital shade selection techniques. MATERIALS AND METHODS. Teeth numbers 11 and 21 were prepared on a typodont model. For the #11 tooth, six different crowns were fabricated with randomly selected colors and set as the target crowns. The following four test groups were established: Group C, where the visual shade selection was performed using the Vita 3D Master Shade Guide and the group served as the control; Group Ph, where the shade selection was performed under the guidance of dental photography; Group S, where the shade selection was performed by measuring the target tooth color using a spectrophotometer; and Group I, where the shade selection was performed by scanning the test specimens and target crowns using an intraoral scanner. Based on the test groups, 24 crowns were fabricated using different shade selection techniques. The ΔE values were calculated according to the CIEDE2000 (2:1:1) formula. The collected data were analyzed by means of a one-way analysis of variance. RESULTS. For the four test groups (Groups C, Ph, S, and I), the following mean ΔE values were obtained: 2.74, 3.62, 2.13, and 3.5, respectively. No significant differences were found among the test groups. CONCLUSION. Although there was no statistically significant difference among the shade selection techniques, Group S had relatively lower ΔE values. Moreover, according to the test results, the spectrophotometer shade selection technique may provide more successful clinical results.

A Research on a Model Electronic Resource Management Policy in Academic Libraries (대학도서관 전자자원관리정책 모형 연구)

  • Chang, Durk Hyun
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.47 no.4
    • /
    • pp.125-142
    • /
    • 2013
  • A collection development policy is the library's master plan that provides library's long/short-term plans. It also informs the community of the library's commitment in collection development. However, in Korea, libraries which maintain such a policy are not yet to be easily found. Furthermore, due to increasing importance of electronic resources, libraries are gradually required to have electronic resource management policy that reflects a change in the information environment. The purpose of this study is to suggest a model electronic resource management policy in academic libraries. It derived and verified more than thirty preliminary elements from literature and case studies. The elements were modified and supplemented, and as a result, the selection criteria gained the highest marks. The findings can be applied for selecting the elements of digital collection development policy in the university library and reorganizing them so as to meet its peculiarities. This study, finally, presents a model that includes a guideline for the university library which will establish digital collection development policy.

Asymmetric Index Management Scheme for High-capacity Compressed Databases (대용량 압축 데이터베이스를 위한 비대칭 색인 관리 기법)

  • Byun, Si-Woo;Jang, Seok-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.293-300
    • /
    • 2016
  • Traditional databases exploit a record-based model, where the attributes of a record are placed contiguously in a slow hard disk to achieve high performance. On the other hand, for read-intensive data analysis systems, the column-based compressed database has become a proper model because of its superior read performance. Currently, flash memory SSD is largely recognized as the preferred storage media for high-speed analysis systems. This paper introduces a compressed column-storage model and proposes a new index and its data management scheme for a high-capacity data warehouse system. The proposed index management scheme is based on the asymmetric index duplication and achieves superior search performance using the master index and compact index, particularly for large read-mostly databases. In addition, the data management scheme contributes to the read performance and high reliability by compressing the related columns and replicating them in two mirrored SSD. Based on the results of the performance evaluation under the high workload conditions, the data management scheme outperforms the traditional scheme in terms of the search throughput and response time.

Visualization and Workspace Analysis of Manipulator using the Input Device in Virtual Environment (가상 환경에서 입력장치를 이용한 매니퓰레이터의 작업영역 분석 및 시각화)

  • Kim Sung Hyun;Song Tae Gil;Yoon Ji Sup;Lee Geuk
    • Journal of Digital Contents Society
    • /
    • v.5 no.1
    • /
    • pp.22-27
    • /
    • 2004
  • To handle the high level radioactive materials such a spent fuel, the master-slave manipulaters (MSM) are wide1y used as a remote handling device in nuclear facilities such as the hot cell with sealed and shielded space. In this paper, the Digital Mockup which simulates the remote operation of the Advanced Conditioning Process(ACP) is developed. Also, the workspace and the motion of the slave manipulator, as well as, the remote operation task should be analyzed. The process equipment of ACP and Maintenance/Handling Device are drawn in 3D CAD model using IGRIP. Modeling device of manipulator is assigned with various mobile attributes such as a relative position, kinematics constraints, and a range of mobility. The 3D graphic simulator using the extermal input device of spare ball displays the movement of manipulator. To connect the exterral input device to the graphic simulator, the interface program of external input device with 6 DOF is deigned using the Low Level Tele-operation Interface(LLTI). The experimental result show that the developed simulation system gives much-improved human interface characteristics and shows satisfactory reponse characteristics in terms of synchronization speed. This should be useful for the development of work`s education system in the environment.

  • PDF