• Title/Summary/Keyword: Digital Mammography

Search Result 72, Processing Time 0.03 seconds

Association Between Body Mass Index and Breast Density Using Digital Mammography (체질량지수와 디지털유방촬영술상의 유방밀도와의 연관성)

  • Kim, Mi-Young;Kim, Hwa-Sun
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.267-272
    • /
    • 2014
  • It is well known that low body mass index and younger age are associated with high breast density. Mammographic dense breast has been reported both as a cause of false-negative findings on mammography and as an indicator of increased breast cancer risk. The purpose of this study was to evaluate the association between breast density and body mass index. Furthermore, we considered proper screening method of breast cancer in Korean women. The study was performed on 496 women who underwent health checkup in a university hospital. Age and body mass index were negatively associated with breast density respectively. In postmenopausal women, age and body mass index showed statistically significant association with breast density. Therefore, we should consider sensitive additional method for breast cancer screening especially in younger age and underweight women.

Role of Breast Tomosynthesis in Diagnosis of Breast Cancer for Japanese Women

  • Takamoto, Yayoi;Tsunoda, Hiroko;Kikuchi, Mari;Hayashi, Naoki;Honda, Satoshi;Koyama, Tomomi;Ohde, Sachiko;Yagata, Hiroshi;Yoshida, Atsushi;Yamauchi, Hideko
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.3037-3040
    • /
    • 2013
  • Introduction: Mammography is the most basic modality in breast cancer imaging. However, the overlap of breast tissue depicted on conventional two-dimensional mammography (2DMMG) may create significant obstacles to detecting abnormalities, especially in dense or heterogeneously dense breasts. In three-dimensional digital breast tomosynthesis (3DBT), tomographic images of the breast are reconstructed from multiple projections acquired at different angles. It has reported that this technology allows the generation of 3D data, therefore overcoming the limitations of conventional 2DMMG for Western women. We assessed the detectability of lesions by conventional 2DMMG and 3DBT in diagnosis of breast cancer for Japanese women. Methods: The subjects were 195 breasts of 99 patients (median age of 48 years, range 34~82 years) that had been pathologically diagnosed with breast cancer from December 20, 2010 through March 31, 2011. Both conventional 2DMMG and 3DBT imaging were performed for all patients. Detectability of lesions was assessed based on differences in category class. Results: Of the affected breasts, 77 (75.5%) had lesions assigned to the same categories by 2DMMG and 3DBT. For 24 (23.5%) lesions, the category increased in 3DBT indicating improvement in diagnostic performance compared to 2DMMG. 3DBT improved diagnostic sensitivity for patients with mass, focal asymmetric density (FAD), and architectural distortion. However, 3DBT was not statistically superior in diagnosis of the presence or absence of calcification. Conclusions: In this study, 3DBT was superior in diagnosing lesions in form of mass, FAD, and/or architectural distortion. 3DBT is a novel technique that may provide a breakthrough in solving the difficulties of diagnosis caused by parenchyma overlap for Japanese women.

Semi-automatic System for Mass Detection in Digital Mammogram (디지털 마모그램 반자동 종괴검출 방법)

  • Cho, Sun-Il;Kwon, Ju-Won;Ro, Yong-Man
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.153-161
    • /
    • 2009
  • Mammogram is one of the important techniques for mass detection, which is the early diagnosis stage of a breast cancer. Especially, the CAD(Computer Aided Diagnosis) using mammogram improves the working performance of radiologists as it offers an effective mass detection. There are two types of CAD systems using mammogram; automatic and semi-automatic CAD systems. However, the automatic segmentation is limited in performance due to the difficulty of obtaining an accurate segmentation since mass occurs in the dense areas of the breast tissue and has smoother boundaries. Semi-automatic CAD systems overcome these limitations, however, they also have problems including high FP (False Positive) rate and a large amount of training data required for training a classifier. The proposed system which overcomes the aforementioned problems to detect mass is composed of the suspected area selection, the level set segmentation and SVM (Support Vector Machine) classification. To assess the efficacy of the system, 60 test images from the FFDM (Full-Field Digital Mammography) are analyzed and compared with the previous semi-automatic system, which uses the ANN classifier. The experimental results of the proposed system indicate higher accuracy of detecting mass in comparison to the previous systems.

A Nonlinear Image Enhancement Method for Digital Mammogram (디지털 맘모그램을 위한 비선형 영상 향상 방법)

  • Jeon, Geum-Sang;Kim, Sang-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.14 no.1
    • /
    • pp.6-12
    • /
    • 2013
  • Mammography is the most common technique for the early detection of breast cancer. To diagnose correctly and treat of breast cancer efficiently, many image enhancement methods have been developed. This paper presents a nonlinear image enhancement method for the enhancement of digital mammogram. The proposed method is composed of a nonlinear function for brightness improvement and a nonlinear filter for contrast enhancement. The nonlinear function improves the brightness of dark area and extends the dynamic range of bright area, and the nonlinear filter efficiently enhances the specific regions and objects of the mammogram. The final enhanced image was obtained by combining the processed image with the nonlinear function and the filtered image with the nonlinear filter. The proposed nonlinear image enhancement method was confirmed the enhanced performance comparing with other existing methods.

Multi-layer design of Hybrid method for digital X-ray imaging (디지털 X-ray imaging을 위한 Hybrid 방식의 다층구조 설계)

  • Cho, Sung-Ho;Park, Ji-Koon;Lee, Dong-Gil;Kim, Dae-Hwan;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.75-78
    • /
    • 2003
  • In recent years, there has been keen interest in developing flat panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy, electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of ZnS(Ag) photoemission layer and a-Se photoconductor layer to resolve problem of conventional x-ray detector such as the direct detector and the indirect detector. To design the structure of ZnS(Ag)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Also, we carried out the experiment to demonstrate the result of MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m$-ZnS(Ag) film was above 87%, 75% at 60 and 80 kVp. As a results, we can determined the thickness of suitable phosphor and the thickness of photoconductor.

  • PDF

Comparative Analysis According to Acquisition Type by Using the Resolution Phantom for Mammography Equipment (유방촬영의 영상획득 방법에 따른 해상력 차트의 비교 분석)

  • Kim, Jae-Hoon;Ji, Yun-Sang;Dong, Kyung-Rae;Kwak, Jong-Gil
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.287-290
    • /
    • 2018
  • Nowadays, diseases related with breast are increasing rapidly and because of this high quality of resolution images is required to get clear detail specially for early detection and diagnosis. It has a tendency to use digital equipments than analog one in clinic. In this experiment, DR, CR, and Film are used for the resolution applied by AEC. Resolution phantom in DR was $7LP{\cdot}mm^{-1}$ in both verticality and horizontality. In CR, however, it was $6LP{\cdot}mm^{-1}$ in both which was lower this standard. The resolution stayed in range of standard in Film but it showed differences between $11{\sim}14LP{\cdot}mm^{-1}$ Overall, the difference of resolution was displayed Film, DR and CR, in order, which means the study is needed for more high quality of digital images.

Region Segmentation using Discrete Morse Theory - Application to the Mammography (이산 모스 이론을 이용한 영역 분할 - 맘모그래피에의 응용)

  • Hahn, Hee Il
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.1
    • /
    • pp.18-26
    • /
    • 2019
  • In this paper we propose how to detect circular objects in the gray scale image and segment them using the discrete Morse theory, which makes it possible to analyze the topology of a digital image, when it is transformed into the data structure of some combinatorial complex. It is possible to get meaningful information about how many connected components and topologically circular shapes are in the image by computing the persistent homology of the filtration using the Morse complex. We obtain a Morse complex by modeling an image as a cubical cellular complex. Each cell in the Morse complex is the critical point at which the topological structure changes in the filtration consisting of the level sets of the image. In this paper, we implement the proposed algorithm of segmenting the circularly shaped objects with a long persistence of homology as well as computing persistent homology along the filtration of the input image and displaying in the form of a persistence diagram.

Denoising of Digital Mammography Images Using Wavelet Transform (웨이블릿을 이용한 디지털유방영상의 노이즈 제거)

  • Choi, Seokyoon;Ko, Seongjin;Kang, Sesik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • The optimum exposure parameters are found when examined using the automatic mode in FFDM. improve the image quality by applying denoising algorithm and propose methods to reduce AGD(Average Grandular Dose) a patient can receive. For the experiment, Nuclear Associates Model 18-222 phantom was the used, and the entrance dose and AGD were measured. And then, Signal, Noise, SNR and FOM(Figure of Merit) were measured, compared and analyzed image denoising before and after. As the experiment result, first, SNR was the highest at Mo/Mo 23kVp and W/Rh 35kvp was the lowest for the average glandular dose. It showed to use 28kVp of W/Rh to be the best through the result of FOM. SNR was the highest at Mo/Mo 23kVp(image denoising), and it showed to W/Rh and 28kVp to be the best in the FOM result which AGD was considered at the same time. By the image denoising, it is possible to reduce noise while maintain important information in the image.

A Study on the Image Enhancement Method of Digital Mammogram in the Wavelet Domain (웨이블렛 영역에서 디지털 맘모그램의 영상향상 방법에 관한 연구)

  • Jeon, Geum-Sang;Jang, Boo-Hwan;Kim, Sang-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.6-11
    • /
    • 2012
  • Digital mammogram is effective for detecting the micro-calcification that is early symptom of breast cancer. In the digital mammogram, many image processing techniques have been studied for accurate diagnosis and efficient treatment of micro-calcification lesion. The wavelet based multi-scale method was mainly used to enhance the image contrast. This paper presents an advanced mammography enhancement method which is based both on the brightness and the contrast enhancement in the wavelet domain. The proposed method normalizes a dynamic range using histogram of the image. The brightness is enhanced by modifying coefficients of low frequency components, and the contrast is enhanced by coefficients of high frequency component based on the multi-scale contrast measure. The experiment results show that the proposed method yields better performance of the image enhancement over the existing methods.

A Contrast Enhancement Method using the Contrast Measure in the Laplacian Pyramid for Digital Mammogram (디지털 맘모그램을 위한 라플라시안 피라미드에서 대비 척도를 이용한 대비 향상 방법)

  • Jeon, Geum-Sang;Lee, Won-Chang;Kim, Sang-Hee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.2
    • /
    • pp.24-29
    • /
    • 2014
  • Digital mammography is the most common technique for the early detection of breast cancer. To diagnose the breast cancer in early stages and treat efficiently, many image enhancement methods have been developed. This paper presents a multi-scale contrast enhancement method in the Laplacian pyramid for the digital mammogram. The proposed method decomposes the image into the contrast measures by the Gaussian and Laplacian pyramid, and the pyramid coefficients of decomposed multi-resolution image are defined as the frequency limited local contrast measures by the ratio of high frequency components and low frequency components. The decomposed pyramid coefficients are modified by the contrast measure for enhancing the contrast, and the final enhanced image is obtained by the composition process of the pyramid using the modified coefficients. The proposed method is compared with other existing methods, and demonstrated to have quantitatively good performance in the contrast measure algorithm.