• Title/Summary/Keyword: Digital Infrared Thermal Imaging

Search Result 127, Processing Time 0.029 seconds

Implementation of a Thermal Imaging System with Focal Plane Array Typed Sensor (초점면 배열 방식의 열상카메라 시스템의 구현)

  • 박세화;원동혁;오세중;윤대섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.5
    • /
    • pp.396-403
    • /
    • 2000
  • A thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main part of the system is a thermal camera in which a focal plane array typed sensor is introduced. The sensor detects the mid-range infrared spectrum of target objects and then it outputs a generic video signal which should be processed to form a frame thermal image. Here, a digital signal processor(DSP) is applied for the high speed processing of the sensor signals. The DSP controls analog-to-digital converter, performs correction algorithms and outputs the frame thermal data to frame buffers. With the frame buffers can be generated a NTSC signal and transferred the frame data to personal computer(PC) for the analysis and a monitoring of the thermal scenes. By performing the signal processing functions in the DSP the overall system achieves a simple configuration. Several experimental results indicate the performance of the overall system.

  • PDF

A Study on the Improvement of Image Quality for a Thermal Imaging System with focal Plane Array Typed Sensor (초점면 배열 방식 열상 카메라 시스템의 화질 개선 연구)

  • 박세화
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.2
    • /
    • pp.27-31
    • /
    • 2000
  • Thermal imaging system is implemented for the measurement and the analysis of the thermal distribution of the target objects. The main Part of the system is thermal camera in which a focal plane array typed sensor is introduced The sensor detects mid-range infrared spectrum or target objects and then it output generic video signal which should be processed to form a thermal image frame. A digital signal processor(DSP) in the system inputs analog to digital converted data. performs algorithms to improve the thermal images and then outputs the corrected frame data to frame buffers for NTSC encoding and for digital outputs.. To enhance the quality of the thermal images, two point correction method is applied. Figures indicate that the corrected thermal images are much improved.

  • PDF

Automatic Intelligent Asymmetry Detection Using Digital Infrared Imaging with K-Means Clustering

  • Kim, Kwang Baek;Song, Doo Hoen
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.15 no.3
    • /
    • pp.180-185
    • /
    • 2015
  • Digital infrared thermal imaging is a non-invasive adjunctive diagnostic technique that allows an examiner to visualize and quantify changes in skin surface temperature. The asymmetry of temperature differences between the diseased and the contralateral healthy body parts can be automatically analyzed and has been studied in many areas of medical science. In this paper, we propose a method for intelligent automatic asymmetry detection based on a K-means analysis and a YCbCr color model. The implemented software successfully visualizes an asymmetric distribution of colors with respect to the patients’ health status.

A Review of the Domestic Study Trends on Obstetrics & Gynecological Diseases by Using Digital Infrared Thermal Imaging as a Diagnosis Instrument (한방여성의학 영역에서 진단 도구로 적외선 체열 검사(Digital Infrared Thermal Imaging, DITI)를 활용한 국내 연구 동향 분석)

  • Im, Ji-Yeong;Hwang, Deok-Sang;Lee, Jin-Moo;Lee, Chang-Hoon;Jang, Jun-Bock
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.33 no.3
    • /
    • pp.80-94
    • /
    • 2020
  • Objectives: The purpose of this review is to analyze the domestic study trends of clinical use of Digital Infrared Thermal Imaging (DITI) as a diagnosis instrument on obstetrics and gynecological diseases in Korean literature. Methods: We searched for clinical studies using DITI in the journal of Korean obstetrics & gynecology, National Digital Science Library, Research Information Sharing Service, Korean Medical Database up to May 2020. After searching studies, we selected studies and analyzed according to disease. Results: 18 clinical studies were published in two kinds of academic journals. There were 4 studies about dysmenorrhea and menopausal symptoms, 2 studies about postpartum disease and hypercryalgesia, 1 study about amenorrhea, premenstrual syndrome, leukorrhea, infertility, polycystic ovary syndrome and hot flush. Conception vessel was frequently used for DITI measurement, followed by stomach meridian. The temperatures of abdomen (CV4, CV12), face (HN3), upper and lower limb (PC8, LU4, LR3, ST32) were commonly measured. Conclusions: This study shows that DITI could be one of effective diagnosis instrument for obstetrics and gynecological diseases. More well-designed clinical studies using DITI will be needed.

Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging (체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰)

  • Lee, Hyun-Sook
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.180-184
    • /
    • 2011
  • The changes in the blood flow in the peripheral vascular system under strong pulsed magnetic fields (pMF) were studied by digital infrared thermal imaging (DITI). After pMF stimulus temperatures in stimulated area were commonly increased in both groups of age and gender. In order to reduce heat generated from coil in pMF stimulus system plastic moldings were fabricated, so that certain distance was kept between stimulus system and the skin and to prevent direct contact to the skin. It is believed that skin temperature is increased by internal electromagnetic energy stimulated the peripheral vascular system by non-contact method.

Characteristics of Infrared Blocking, Stealth and Color Difference of Aluminum Sputtered Fabrics

  • Han, Hye Ree
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.4
    • /
    • pp.592-604
    • /
    • 2019
  • This study examines the stealth function of sputtered fabric with an infrared thermal imaging camera in terms of the thermal and infrared (IR) transmittance characteristics. Various base fabrics were selected, infrared imaging was performed, and infrared transmittance was measured. By infrared camera experiment it was found that the sample was concealed because it had a similar color to the surroundings when the aluminum layer was directed toward the outside. In addition, a comparison of the infrared thermographic image of the untreated sample and the sputtered sample in the laboratory showed that the difference in ${\Delta}E$ value ranged from 31 to 90.4 and demonstrated effective concealment. However, concealment was not observed in the case of the 3-layer (Nylon-Al-Nylon) model when a sputtered aluminum layer existed between two nylon layers. The direction of the sputtering layer did not affect the infrared transmittance in the infrared transmittance experiment. Therefore, it seems better to interpret the concealing effect in the infrared thermographic images by using thermal transfer theory rather than infrared transmittance theory. We believe that the results of this study will be applicable to developing high performance smart clothing and military uniforms.

Digital Infrared Thermal Imaging of Crape Myrtle Leaves Infested with Sooty Mold

  • Kim, Jiyeon;Kweon, Si-Gyun;Park, Junhyung;Lee, Harim;Kim, Ki Woo
    • The Plant Pathology Journal
    • /
    • v.32 no.6
    • /
    • pp.563-569
    • /
    • 2016
  • The spatial patterns for temperature distribution on crape myrtle leaves infested with sooty mold were investigated using a digital infrared thermal imaging camera. The mean temperatures of the control and sooty regions were $26.98^{\circ}C$ and $28.44^{\circ}C$, respectively. In the thermal images, the sooty regions appeared as distinct spots, indicating that the temperatures in these areas were higher than those in the control regions on the same leaves. This suggests that the sooty regions became warmer than their control regions on the adaxial leaf surface. Neither epidermal penetration nor cell wall dissolution by the fungus was observed on the adaxial leaf surface. It is likely that the high temperature of black leaves have an increased cooling load. To our knowledge, this is the first report on elevated temperatures in sooty regions, and the results show spatial heterogeneity in temperature distribution across the leaf surface.

Clinical Observation on 1 Case of Both Leg Paralysis Patient Diagnosed Wei Symptom (위증(療證)으로 진단한 하지마비 환자의 치험 1례)

  • Wei, Tung-Sheun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.748-752
    • /
    • 2006
  • Wei symptom(?證) is symptom that reveals muscle relaxation without contraction and muscle relaxation occurs in the lower or upper limb, in severe case, leads to death. This is the clinical report about the Wei symptom(?證)-patient doubt as Transverse Myelitis and Conversion Disorder. The patient was treated by acupuncture, moxibustion, herb medication(十全大補湯), electriccal stimulation theraphy, Bee Venom acupuncture, and had significant improvement in Wei symptom(?證). these results suggest the surface temperature differ remarkably from before being treated. The temperature is measured by using Digital Infrared Thermal Imaging(DITI). The results suggest that oriental medicare is an effective treatment for Wei symptom. We expected that therapeutic value of treatment of both leg Paralysis in the oriental medicine will be higher if more clinical studies and researches are accomplished.

A clinical report of thermographic change after Korean Medicine Treatment on post-hysterectomy syndrome patients (자궁적출술 후 증후군의 한방치료 전후 체온분포 변화에 관한 임상보고)

  • Kim, Jihee;Lee, Gi-Seung;Kim, Jun-Cheol
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.14 no.1
    • /
    • pp.52-62
    • /
    • 2014
  • Objective : The aim of this study is to analyze the effectiveness of Korean Medicine treatment on post-hysterectomy syndrome patients by thermographic change during treatment. Methods : 5 female patients who had a hysterectomy within a year were treated with Korean Medicine concluding acupuncture, herbal medicine, cupping therapy, herbal bath. We evaluated the thermographic differences by checking Digital Infrared Thermal Imaging(D.I.T.I.) at CV17(膻中), CV4(關元), ST3(巨髎), BL15(心兪), and BL23(腎兪). Results : In consequence of Korean Medicine Treatment for 3 weeks, thermographic differences between CV17(膻中) and CV4(關元), ST3(巨髎) and CV4(關元), BL15(心兪), and BL23(腎兪) tended to decrease. Conclusion : After Korean Medicine treatment, thermographic differences between upper body and lower body tended to decrease cause shangrexiahanzheng(上熱下寒證) made by hysterectomy became moderated.

Study on the Correlation between Digital Infrared Thermal Imaging-induced Severity of Cold Hypersensitivity of Hands and Feet and Heart Rate Variability (Digital Infrared Thermal Imaging에 따른 수족냉증 중증도와 Heart Rate Variability의 상관관계 연구)

  • Woo, Hye-Lin;Pak, Yeon-Kyeong;Kim, Joon-Ho;Park, Kyoung-Sun;Hwang, Deok-Sang;Lee, Jin-Moo;Jang, Jun-Bock;Lee, Chang-Hoon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.3
    • /
    • pp.1-9
    • /
    • 2016
  • Objectives: Cold Hypersensitivity of Hands and Feet (CHHF) has been diagnosed objectively by Digital Infrared Thermal Imaging (DITI) and has been known to be associated with autonomic nervous system (ANS), which can be assessed by Heart Rate Variability (HRV). This study evaluated the correlation between severity of CHHF and HRV variables.Methods: We studied 155 non-menopausal women with CHHF who visited Kyung Hee University Hospital at Gangdong from 01 October 2013 to 30 April 2016. We measured DITI and HRV of each patient. We used DITI to calculate the severity of CHHF with thermal difference between upper arm (L4, 俠白穴) and palm (P8, 勞宮穴) of both hands and anterior thigh (ST32, 伏兎穴) and dorsum of foot (LI3, 太衝穴) of both feet. The correlation between severity of CHHF and HRV variables were analyzed.Results: In time domain analysis, there was significantly positive correlation between the severity of CHHF and both SDNN and RMSSD. In frequency domain analysis, there was significantly positive correlation between the severity of CHHF and TP, HF and HF Norm while there was significantly negative correlation between the severity of CHHF and LF Norm as well as between the severity of cold hypersensitivity of both hands and LF/HF ratio.Conclusions: The more severe CHHF is, the more increased the function of parasympathetic nerve system (PNS) and relatively decreased the function of sympathetic nerve system (SNS) is. Also, it has known that cold hypersensitivity could be caused by deficiency syndrome and qi deficiency has the same ANS tendency as CHHF. Therefore, in practical fields, this result can be helpful in planning treatment and deciding prognosis in respect of deficiency syndrome.