• Title/Summary/Keyword: Digital Imaging and Communication in Medicine

Search Result 31, Processing Time 0.03 seconds

P2P DICOM System using Multiagent Systems Communicating with XML Encoded ACL (XML 기반 ACL로 통신하는 멀티에이전트 시스템을 이용한 P2P DICOM 시스템)

  • Kwon, Gi-Beom;Kim, Il-Kon
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.5
    • /
    • pp.598-606
    • /
    • 2002
  • We suggest a distributed communication and management methodology using PC to PC Query multicasting strategy for efficient management of medical images produced by DICOM(Digital Imaging and Communications in Medicine) Modalities. It is absolutely necessary to reduce strict degradation of PACS system due to large sire of medical images and their very high transport rates. DICOM PC to PC Component is composed of a Service Manager to execute requested queries, a Communication Manager to take charge of file transmission, and a DICOM Manager to manage stored data and system behavior Each Manager itself is a component to search for requested file by interaction or to transmit the file to other PCs. Distributed management and transformation of medical information based on PC to PC Query multicasting methodology will enhance performance of central server and network capacity, reducing overload on both. We organize three major components for system operation. Each component is implemented as Agent. Communication between agents uses XML encoded Agent Communication Language.

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

  • Shin, Dong Ah;Ji, Gyu Yeul;Oh, Chang Hyun;Kim, Keung Nyun;Yoon, Do Heum;Shin, Hyunchul
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.4
    • /
    • pp.441-447
    • /
    • 2017
  • Objective : Computed tomography (CT)-based method of three dimensional (3D) analysis ($MIMICS^{(R)}$, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of $MIMICS^{(R)}$ system, and inter- and intra-observer reliability in the measurement of OPLL. Methods : Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software ($MIMICS^{(R)}$) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. Results : The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. Conclusion : The medical image processing software ($MIMICS^{(R)}$) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.

Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment

  • Laurino, Fernando Antonio Reis;Choi, Isabela Goulart Gil;Kim, Jun Ho;Gialain, Ivan Onone;Ferraco, Renato;Haetinger, Rainer Guilherme;Pinhata-Baptista, Otavio Henrique;Abdala-Junior, Reinaldo;Costa, Claudio;Cortes, Arthur Rodriguez Gonzalez
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.93-98
    • /
    • 2020
  • Purpose: Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols. Materials and Methods: A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Micro-computed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test. Results: Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and P<0.05; T2-weighted, r=0.713 and P<0.05), buccolingual width (T1-weighted, r=0.892 and P<0.05; T2-weighted, r=0.956 and P<0.05), and anteroposterior depth (T1-weighted, r=0.731 and P<0.05; T2-weighted, r=0.873 and P<0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT. Conclusion: Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

Radiation Oncology Digital Image Chart 8nd Digital Radiotherapv Record System at Samsung Medical Center (디지털 화상 병력 시스템과 디지털 방사선치료 기록 시스템의 개발과 사용 경험)

  • Huh Seung Jae;Ahn Yong Chan;Lim Do Hoon;Cho Chung Keun;Kim Dae Yong;Yeo Inhwan;Kim Moon Kyung;Chang Seung Hee;Park Suk Won
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 2000
  • Background :The authors have developed a Digital image chart(DIC) and digital Radiotherapy Record System (DRRS). We have evaluated the DIC and DRRS for reliability, usefulness, ease of use, and efficiency. Materials and Methods :The basic design of the DIC and DRRS was to build an digital image database of radiation therapy Patient records for a more efficient and timely flow of critical image information throughout the department. This system is a submit of comprehensive radiation oncology management system (C-ROMS) and composed of a picture archiving and communication system (PACS), a radiotherapy information database, and a radiotherapy imaging database. The DIC and DRRS were programmed using Delphi under a Windows 95 environment and is capable of displaying the digital images of patients identification photos, simulation films, radiotherapy setup, diagnostic radiology images, gross lesion Photos, and radiotherapy Planning isodose charts with beam arrangements. Twenty-three clients in the department are connected by Ethernet (10 Mbps) to the central image server (Sun Ultra-sparc 1 workstation). Results :From the introduction of this system in February 1998 through December 1999, we have accumulated a total of 15,732 individual images for 2,556 patients. We can organize radiation therapy in a 'paperless' environment in 120 patients with breast cancer. Using this system, we have succeeded in the prompt, accurate, and simultaneous access to patient care information from multiple locations throughout the department. This coordination has resulted in improved operational efficiency within the department. Conclusion :The authors believe that the DIC and DRRS has contributed to the improvement of radiation oncology department efficacy as well as to time and resource savings by providing necessary visual information throughout the department conveniently and simultaneously. As a result, we can also achieve the 'paperless' and 'filmless' practice of radiation oncology with this system.

  • PDF

A Study on the Usefulness of an Examination Information Printout during Ordinary X-Ray Examinations (일반촬영 검사 시 검사안내 유인물의 유용성에 관한 고찰)

  • Kang, Sang-Oh;Hong, Seong-Kwon;Son, Seok-Ho;Lee, Min-Woo;Kim, Kyeong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.13-20
    • /
    • 2012
  • In a normal x-ray examination, the cooperation of a patient in positioning greatly influences the improvement of work performance, the quality of the images and the reduction in time spent on the examination. An attempt was made to discover the connection between an examination information printout and the effects of the examination by informing the patient before the examination on the examination positions in order to increase the level of cooperation by the patient and by surveying the degree of satisfaction of the patient during the examination proceedings. An examination information printout was prepared on five positions that patients consider to be difficult while receiving normal x-ray examinations and were shown to 257 male and female patients between the ages of 30 to 79 who had visited this hospital between January 1 to February 29, 2012 or to a person who had accompanied the patients before the examination to research the degree of satisfaction regarding the printout. In addition, the examination explanation printout was given to Radiologic Technologists with over 1 year experience in this hospital to use while taking the x-rays and the degree of satisfaction was surveyed and it was examined if the increase of the degree of satisfaction had an effect on the reduction in the examination time. The patients who utilized the examination information printout revealed results of approximately a 7.8% higher degree of satisfaction among the patients who had previous experience receiving x-ray examinations compared to those were having an x-ray for the first time. In the age groups between 30 to 70 years of age, the age group in the 30's revealed the lowest level of satisfaction at approximately 69% and the group in the 50's showed the highest degree of satisfaction of 87.94%. In the survey of the Radiologic Technologists, 85% responded that they were satisfied. In the question that stated "Will the examination information printouts reduce the time involved in unnecessary conversations with the patients?," the responses showed a 95% degree of satisfaction. The degree of satisfaction was high over the examination information printout by both the patients and the Radiologic Technologists. Although the effects of examination time reduction varied based on the ages of the patients and physical conditions that they were in and could not be given measurement values, it was able to be seen through the survey that reduction of the unnecessary communication between the patient and the Radiologic Technologists contributed to the increase in the degree of satisfaction. As a result, both the patients and the Radiologic Technologists had an increased degree of satisfaction over the examination information printout and it was possible for improvements to be made in the quality of medical service provided as well. Nevertheless, it is considered that a more developed manual in terms of quality and quantity must be produced using a more systematic approach and design.

  • PDF

Is the panoramic mandibular index useful for bone quality evaluation?

  • Kwon, Ah-Young;Huh, Kyung-Hoe;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.87-92
    • /
    • 2017
  • Purpose: The aim of this study was to determine whether the panoramic mandibular index (PMI) is useful for assessing bone mineral density. We also analyzed the potential correlations between PMI parameters and patient age. Materials and Methods: Four observers measured the PMI of both sides of the mental foramen using a picture archiving and communication system and images in the Digital Imaging and Communications in Medicine format. They studied 300 panoramic radiographic images of patients belonging to the following age groups: 40-49 years, 50-59 years, 60-69 years, 70-79 years, and 80-89 years. The observers were allowed to zoom in or out and to adjust the contrast of the images. Further, they were instructed to record the reasons for any measurements that could not be made. Then, we conducted a reliability analysis of the measured PMI and assessed the correlations between different patient age groups and the 3 parameters used for determining the PMI from the available data. Results: Among the 600 data items collected, 23 items were considered unmeasurable by at least 1 observer for the following 4 reasons: postoperative state, lesion, unidentified mental foramen, and alveolar bone loss. The intraobserver reproducibility of the measurable data was 0.611-0.752. The mandibular cortical width (MCW) decreased significantly as patient age increased. Conclusion: PMI had limited usability when the margin of the mental foramen was not clear. In contrast, MCW, a parameter used for determining the PMI, had fewer drawbacks than the PMI with respect to bone mineral density measurements and exhibited a significant correlation with patient age.

PDA Transmission of Medical Images by CDMA (CDMA에 의한 의료영상의 PDA전송)

  • Lee, Myong-Ho;Lim, Jae-Dong;Ahn, Bung-Ju;Lee, Hwun-Jae;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.2
    • /
    • pp.13-22
    • /
    • 2007
  • The purpose of this study was to survey a development of the wireless transmission system of medical images for ubiquitous medicine. There have been many changes in medical equipments and medical record medical treatment and medical record within hospital and PACS(Picture Archiving Communication System) which is picture management system for patients can be typical cases. It is difficult to use these automated medical systems unless they are within hospital and in case of rapid image reading in the emergency cases or in absence of doctor, it is difficult to perform it immediately. The present study implemented an image transmission system using CDMA connection so that images in the server can be viewed at any time and in any place. Remote wireless diagnosis based on medical images using PDA is applicable to medical areas that require mobility, and the use of PDA can be an ideal alternative for point of care. The use of PDA enables prompt and accurate access to digital medical images, which in turn reduces medical accidents and improves the quality of medical services through high productivity and efficiency of medical practitioners' works. It also enables quick response to patients' demands and high-quality medical services and, consequently, patients' high satisfaction.

  • PDF

Minimizing the extra-oral time in autogeneous tooth transplantation: use of computer-aided rapid prototyping (CARP) as a duplicate model tooth

  • Lee, Seung-Jong;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.3
    • /
    • pp.136-141
    • /
    • 2012
  • Objectives: The maintenance of the healthy periodontal ligament cells of the root surface of donor tooth and intimate surface contact between the donor tooth and the recipient bone are the key factors for successful tooth transplantation. In order to achieve these purposes, a duplicated donor tooth model can be utilized to reduce the extra-oral time using the computer-aided rapid prototyping (CARP) technique. Materials and Methods: Briefly, a three-dimensional digital imaging and communication in medicine (DICOM) image with the real dimensions of the donor tooth was obtained from a computed tomography (CT), and a life-sized resin tooth model was fabricated. Dimensional errors between real tooth, 3D CT image model and CARP model were calculated. And extra-oral time was recorded during the autotransplantation of the teeth. Results: The average extra-oral time was 7 min 25 sec with the range of immediate to 25 min in cases which extra-oral root canal treatments were not performed while it was 9 min 15 sec when extra-oral root canal treatments were performed. The average radiographic distance between the root surface and the alveolar bone was 1.17 mm and 1.35 mm at mesial cervix and apex; they were 0.98 mm and 1.26 mm at the distal cervix and apex. When the dimensional errors between real tooth, 3D CT image model and CARP model were measured in cadavers, the average of absolute error was 0.291 mm between real teeth and CARP model. Conclusions: These data indicate that CARP may be of value in minimizing the extra-oral time and the gap between the donor tooth and the recipient alveolar bone in tooth transplantation.

Three-dimensional evaluation of the correlation between lip canting and craniofacial planes

  • Kim, Jun-Young;Park, Hee-Keun;Shin, Seung-Woo;Park, Jin Hoo;Jung, Hwi-Dong;Jung, Young-Soo
    • The korean journal of orthodontics
    • /
    • v.50 no.4
    • /
    • pp.258-267
    • /
    • 2020
  • Objective: This study aimed to analyze the correlation of horizontal and sagittal planes used in two-dimensional diagnosis with lip canting by using three-dimensional (3D) analysis. Methods: Fifty-two patients (25 men, 27 women; average age: 24 years) undergoing treatment for dentofacial deformity were enrolled. Computed tomography images were acquired, and digital imaging and communication in medicine files were reconstructed into a 3D virtual model wherein horizontal and sagittal craniofacial planes were measured. Subsequently, the correlations of lip canting with these horizontal and sagittal planes were investigated. Results: The mandibular symmetry plane, the occlusal plane, Camper's plane, the mandibular plane, Broadbent's plane, and the nasal axis plane were correlated with the amount of lip canting (Pearson's correlation coefficients: 0.761, 0.648, 0.556, 0.526, 0.438, and 0.406, respectively). Planes associated with the lower part of the face showed the strongest correlations; the strength of the correlations decreased in the midfacial and cranial regions. None of the planes showed statistically significant differences between patients with clinical lip canting (> 3°) and those without prominent lip canting. Conclusions: The findings of this study suggest that lip canting is strongly correlated with the mandibular symmetry plane, which includes menton deviation. This finding may have clinical implications with regard to the treatment of patients requiring correction of lip canting. Further studies are necessary for evaluating changes in lip canting after orthognathic surgery.

Design and Implementation of Medical Information System using QR Code (QR 코드를 이용한 의료정보 시스템 설계 및 구현)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.16 no.2
    • /
    • pp.109-115
    • /
    • 2015
  • The new medical device technologies for bio-signal information and medical information which developed in various forms have been increasing. Information gathering techniques and the increasing of the bio-signal information device are being used as the main information of the medical service in everyday life. Hence, there is increasing in utilization of the various bio-signals, but it has a problem that does not account for security reasons. Furthermore, the medical image information and bio-signal of the patient in medical field is generated by the individual device, that make the situation cannot be managed and integrated. In order to solve that problem, in this paper we integrated the QR code signal associated with the medial image information including the finding of the doctor and the bio-signal information. bio-signal. System implementation environment for medical imaging devices and bio-signal acquisition was configured through bio-signal measurement, smart device and PC. For the ROI extraction of bio-signal and the receiving of image information that transfer from the medical equipment or bio-signal measurement, .NET Framework was used to operate the QR server module on Window Server 2008 operating system. The main function of the QR server module is to parse the DICOM file generated from the medical imaging device and extract the identified ROI information to store and manage in the database. Additionally, EMR, patient health information such as OCS, extracted ROI information needed for basic information and emergency situation is managed by QR code. QR code and ROI management and the bio-signal information file also store and manage depending on the size of receiving the bio-singnal information case with a PID (patient identification) to be used by the bio-signal device. If the receiving of information is not less than the maximum size to be converted into a QR code, the QR code and the URL information can access the bio-signal information through the server. Likewise, .Net Framework is installed to provide the information in the form of the QR code, so the client can check and find the relevant information through PC and android-based smart device. Finally, the existing medical imaging information, bio-signal information and the health information of the patient are integrated over the result of executing the application service in order to provide a medical information service which is suitable in medical field.