• Title/Summary/Keyword: Digital Images

Search Result 3,364, Processing Time 0.038 seconds

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

Elemental Image and Sub Image Generation of Integral Imaging using 4-step Phase-shifting Digital holography of 3-dimensional Object (3차원 물체의 4단계 위상천이 디지털 홀로그래피를 이용한 접적영상의 요소영상과 부영상의 생성)

  • Jeong, Min-Ok;Kim, Nam;Park, Jae-Hyeong;Jeon, Seok-Hui
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.263-264
    • /
    • 2009
  • We propose a method synthesizing elemental images and sub-images for the integral imaging using phase-shifting digital holography. From acquired single 4-step phase-shifting digital holography, we can generate elemental images and sub-images for any lens array specifications.

  • PDF

DEM generation with other sensor images using digital photogrammetry techniques

  • Lee, Sung-Soon;Chi, Kwang-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.182-182
    • /
    • 2003
  • Generally, DEM (Digital Elevation Model) is generated by stereo-images acquired same conditions, sensor type, viewing angle, capturing elevation and etc. It is difficult to generate DEM with stereo images acquired different satellite. This study intends that it is DEM generation using pair-images with other sensor systems.

  • PDF

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

CERTAIN TOPOLOGICAL METHODS FOR COMPUTING DIGITAL TOPOLOGICAL COMPLEXITY

  • Melih Is;Ismet Karaca
    • Korean Journal of Mathematics
    • /
    • v.31 no.1
    • /
    • pp.1-16
    • /
    • 2023
  • In this paper, we examine the relations of two closely related concepts, the digital Lusternik-Schnirelmann category and the digital higher topological complexity, with each other in digital images. For some certain digital images, we introduce κ-topological groups in the digital topological manner for having stronger ideas about the digital higher topological complexity. Our aim is to improve the understanding of the digital higher topological complexity. We present examples and counterexamples for κ-topological groups.

A Study on the Aesthetic Ontology of Digital Hybrid Image (디지털 하이브리드 이미지 존재론에 관한 연구)

  • Jeong, Heon
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.1
    • /
    • pp.117-124
    • /
    • 2019
  • This paper investigates how digital technology innovates the aesthetic ontology of film images. The modern civilization of computer and internet bring about the new ontology of film images. Digital hybrid image expands the contradictory combination of physical reality and filmic fantasy. It is inevitable to recount Walter Benjamin' s concept of mechanical reproduction in the age of digital cinema. The modern condition of image arts changes the concept of mechanical reproduction to the logic of digital configuration. In addition, computer simulation innovates the film aesthetics of montage to the aesthetics of digital collage. The technological and aesthetical development of computer simulation and internet network leads to the new ontology of digital hybrid images. This study suggests a new theoretic point that the aesthetic ontology of digital hybrid images leads to the expansion of filmic fantasy and expression.

Analysis of X-ray image qualities-accuracy of shape and clearness of image-using X-ray digital tomosynthesis

  • Roh, Young Jun;Kang, Sung Taek;Kim, Hyung Cheol;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.572-576
    • /
    • 1997
  • X-ray laminography and DT(digital tomosynthesis) that can form a cross-sectional image of 3-D objects promise to be good solutions for inspecting interior defects of industrial products. The major factors of the digital tomosynthesis that influence on the quality of x-ray cross-sectional images are also discussed. The quality of images acquired from the DT system varies according to image synthesizing methods, the number of images used in image synthesizing, and X-ray projection angles. In this paper, a new image synthesizing method named 'log-root method' is proposed to get clear and accurate cross-sectional images, which can reduce both artifact and blurring generated by materials out of focal plane. To evaluate the quality of cross-sectional images, two evaluating criteria: (1) shape accuracy and (2) clearness in the cross-sectional image are defined. Based on this criteria, a series of simulations were performed, and the results show the superiority of the new synthesizing method over the existing ones such as averaging and minimum method.

  • PDF

CAD Model Construction Using Topology Optimization (위상최적설계를 이용한 CAD 모델 구축)

  • Lee, Dong-Hoon;Min, Seung-Jae;Seo, Sang-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.523-528
    • /
    • 2002
  • Topology optimization is widely accepted as a conceptual design tool for the product design. Since the resulted layout of the topology optimization is a kind of digital images represented by the density distribution, the seamless process is required to transform digital images to the CAD model for the practical use. In this paper, the general process to construct a CAD model is developed to apply for topology images based on elements. The node density and the morphology technique is adopted to extract boundary contour of the shape and remove the noise of images through erosion and dilation operation. The proposed method automatically generates point data sets of the geometric model. The process is integrated with Pro/Engineer, so that the engineer in practice can directly handle with curves or surface form digital images.

  • PDF

Similarity Evaluation on Images of Textile Print Design for Digital Library (Digital Library를 위한 텍스타일 프린트 디자인의 이미지 유사성 평가)

  • Lee, Chae-Jung;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.10 no.4
    • /
    • pp.631-637
    • /
    • 2007
  • This research focuses on similarity evaluation of images according to tones of images. Color space of images were converted RGB color space into HSI color space. The information entropy criteria has been taken for evaluating similarity of images for digital library. The similarity was then calculated by combining correlation coefficients and information entropy. Those two values are further analyzed with a relation to human sensibility.

  • PDF

A Study on Large Scale Digital Mapping Using High Resolution Satellite Images (고해상도 위성영상을 이응한 대축척 수치지도 제작에 관한 연구)

  • 윤홍식;조재명;조정호
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.321-326
    • /
    • 2003
  • The subjects of this study are to examine and to apply the methods of making 1:5,000 scale maps using 1m resolution stereo images of IKONOS for the Munsan area of Paju-city where aerial photo surveying cannot possible because of security conditions. GCP(Ground Control Point) were acquired from GPS surveying and were to perform geometric corrections on images. Digital Map used IKONOS stereo images and it worked from the digital analytical stereoplotter. From field investigation, RMSE errors of the plane and vertical positions are estimated to 1.706m and 1.231m, respectively. The plane accuracy is better than an accuracy required by NGIS (national GIS) programs. Local information from field investigation was added and the resulting maps should be good as digital map under the scale of 1/5,000.

  • PDF