• Title/Summary/Keyword: Digital Image Analysis

Search Result 1,509, Processing Time 0.034 seconds

Analysis of Landscape Information and Web GIS Implementation of Using 3D Topographic Modeling (3차원 지형모델링에 의한 경관정보 분석과 Web GIS 구현)

  • Kim, Yong-Suk;Hong, Soon-Heon;Ok, Chi-Yul
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.9
    • /
    • pp.204-211
    • /
    • 2007
  • In this study 3D topographic modeling was made by using aerial photography and digital terrain map, through this we did visibility analysis and implemented Web GIS of Dong-A university. Studying area was Busan Saha-gu Hadan-dong, we used aerial photography on a scale of 1:20,000 and digital terrain map on a scale of 1:5,000. Ortho correction image was made by aerial photography through selecting GCP, image matching, image resampling and precise differential rectification. And DEM on digital map was created using ArcView program, making 3D topographic modeling by road layer and building layer and implementing Web GIS about Dong-A university.

Simulation of amorphous selenium considering diffraction and interference models (간섭과 회절 모델을 고려한 비정질 셀레늄(a-Se) 시뮬레이션)

  • Kim, Si-hyung;Song, Kwang-soup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.997-999
    • /
    • 2012
  • Digital X-ray image detector is widely used for radiodiagnosis. Amorphous selenium has been received attention as one of the major material that confirmed photoconductor of direct methode detector. We analysis the photocurrent using 2-dimensional device simulator when blue-ray (${\lambda}=486nm$) is irradiated and high voltage is biased. We evaluate electron-hole generation rate, electron-hole recombination rate, and electron/hole distribution in the amorphous selenium. This simulation methode is helpful to the analysis of digital X-ray image detector. We expect that many applications will be developed in digital X-ray image detector using 2-dimensional device simulator.

  • PDF

Proposal of AI-based Digital Forensic Evidence Collecting System

  • Jang, Eun-Jin;Shin, Seung-Jung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.124-129
    • /
    • 2021
  • As the 4th industrial era is in full swing, the public's interest in related technologies such as artificial intelligence, big data, and block chain is increasing. As artificial intelligence technology is used in various industrial fields, the need for research methods incorporating artificial intelligence technology in related fields is also increasing. Evidence collection among digital forensic investigation techniques is a very important procedure in the investigation process that needs to prove a specific person's suspicions. However, there may be cases in which evidence is damaged due to intentional damage to evidence or other physical reasons, and there is a limit to the collection of evidence in this situation. Therefore, this paper we intends to propose an artificial intelligence-based evidence collection system that analyzes numerous image files reported by citizens in real time to visually check the location, user information, and shooting time of the image files. When this system is applied, it is expected that the evidence expected data collected in real time can be actually used as evidence, and it is also expected that the risk area analysis will be possible through big data analysis.

Data Augmentation Method for Deep Learning based Medical Image Segmentation Model (딥러닝 기반의 대퇴골 영역 분할을 위한 훈련 데이터 증강 연구)

  • Choi, Gyujin;Shin, Jooyeon;Kyung, Joohyun;Kyung, Minho;Lee, Yunjin
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.3
    • /
    • pp.123-131
    • /
    • 2019
  • In this study, we modified CT images of femoral head in consideration of anatomically meaningful structure, proposing the method to augment the training data of convolution Neural network for segmentation of femur mesh model. First, the femur mesh model is obtained from the CT image. Then divide the mesh model into meaningful parts by using cluster analysis on geometric characteristic of mesh surface. Finally, transform the segments by using an appropriate mesh deformation algorithm, then create new CT images by warping CT images accordingly. Deep learning models using the data enhancement methods of this study show better image division performance compared to data augmentation methods which have been commonly used, such as geometric conversion or color conversion.

Using Image J program, compared of focusing distance and grid rate (Image J 프로그램을 이용한 격자집속거리와 격자비에 따른 영상비교평가)

  • Seo, Won-Joo;Seo, Jeong-Beom;Lee, Jong-Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.1
    • /
    • pp.37-42
    • /
    • 2012
  • Pediatric head and neck phantom, using the rate by focusing distance and grid images, Image J using the Quality Assessment and Dose Area Product compared. X-ray laboratory equipment due to the Philips Digital DIAGNOST a 110 cm FFD set and using ACE Non-grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Focused grid, Acryl Phantom (Fluke Model 76-2 Series Phantom) 15.24 cm, by resolution chart image acquisition, image evaluation program (Image J Ver. 1.4.3.67, USA) imaging experiments were analyzed using. Dose Area Product in the Non Grid 0.028 $mGy{\cdot}cm^2$, focusing distance 110 cm (12 : 1), the 0.129 $mGy{\cdot}cm^2$, 140 cm (12 : 1), the 0.135 $mGy{\cdot}cm^2$, 180 cm (8 : 1) was measured with a 0.110 $mGy{\cdot}cm^2$ Non Grid, focusing distance 110 cm (12 : 1), 140 cm (12 : 1), 180 cm (8 : 1) Image obtained when grid using the image J program focusing distance 110 cm with grid based on the measured SNR and PSNR Non Grid if the SNR the 17.307 dB, PSNR of the 20.002 dB, if the SNR 28.755 dB, PSNR was measured by the 31.451 dB. Image J image analysis through the streets, rather than focusing on grid by the rate that could see an increase in dose. Select the grid by a small dose rate reduction is possible.

  • PDF

Objective and Quantitative Evaluation of Image Quality Using Fuzzy Integral: Phantom Study (퍼지적분을 이용한 영상품질의 객관적이고 정량적 평가: 팬톰 연구)

  • Kim, Sung-Hyun;Suh, Tae-Suk;Choe, Bo-Young;Lee, Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.201-208
    • /
    • 2008
  • Physical evaluations provide the basis for an objective and quantitative analysis of the image quality. Nonetheless, there are limitations in using physical evaluations to judge the utility of the image quality if the observer's subjectivity plays a key role despite its imprecise and variable nature. This study proposes a new method for objective and quantitative evaluation of image quality to compensate for the demerits of both physical and subjective image quality and combine the merits of them. The images of chest phantom were acquired from four digital radiography systems on clinic sites. The physical image quality was derived from an image analysis algorithm in terms of the contrast-to-noise ratio (CNR) of the low-contrast objects in three regions (lung, heart, and diaphragm) of a digital chest phantom radiograph. For image analysis, various image processing techniques were used such as segmentation, and registration, etc. The subjective image quality was assessed by the ability of the human observer to detect low-contrast objects. Fuzzy integral was used to integrate them. The findings of this study showed that the physical evaluation did not agree with the subjective evaluation. The system with the better performance in physical measurement showed the worse result in subjective evaluation compared to the other system. The proposed protocol is an integral evaluation method of image quality, which includes the properties of both physical and subjective measurement. It may be used as a useful tool in image evaluation of various modalities.

  • PDF

Analysis of Big Data by Regimes of Image Contents Field (영상콘텐츠분야 정권별 빅데이터 분석 - 상위 중심성 값의 변화를 중심으로)

  • Hwang, Go-Eun;Moon, Shin-Jung
    • Journal of Digital Contents Society
    • /
    • v.18 no.5
    • /
    • pp.911-921
    • /
    • 2017
  • The purpose of this study was to investigate the semantic network analysis to understand image contents and to examine the degree to which words, word clusters contributed to the formation of semantic map within image contents. For this research, from 1993 until 2016 the field of the image contents were collected for a total of 2,624 cases papers. The word appeared in Title analyzed the social network by using the R program of Big Data. The results were as follows: First, Research on 'education' in the field of image contents has decreased. Second, the role of 'media' in the field of image contents is changing. Finally, It is a change in the status of 'contents' in the field of image contents.

A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied (고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구)

  • Choi, Jun-Gu;Kim, Byeong-Gi;Cha, Seon-Hwa;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • This study aim to investigate image characteristics due to focus-grid and head phantom decentering from the armorphos silicon thin film transistor detector the fixed focus-grid is applied, wish to propose right use method of digital medical equipment. Acquired image according to focus-grid and head phantom position decentering using head phantom on armorphos silicon thin film transistor detector the fixed focus-grid is applied. acquired image evaluate pixel value, histogram, plot profile, surface plot using NIB (Image J) image analysis program and compared decentering image with standard image. Mean value and standard deviation value of focus-grid lateral decentering and duplex decentering of focus-grid and head phantom decreased by ratio, consequently increase of horizontality, diagonal decentering. also, deteriorated contrast of image because frequency of high pixel value decreases fairly. according increases decentering, image distortion phenomenon was increase, by next time, pixel mean value of head phantom decentering was no big change but horizontality, diagonal, mean value and standard deviation value of pixel decreased by ratio. Even if increase pixel noise of image because wide latitude and post processing ability of digital detector, radiotechnologist can not recognize. Therefore, radiotechnologist must recognize correctly the photographing factors which increases pixel noise on the grid system installation digital detector and should exam.

  • PDF

The analysis of interferometry fringe pattern under shearing quantity and inside pressure change for inspect inside defects using by digital shearography (Digital shearography를 이용한 내부결함 검출에 있어서 전단량과 내부압력 변화에 따른 간섭줄무늬 패턴 분석)

  • 김형택;김경석;홍진후;강기수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.140-143
    • /
    • 2001
  • Digital shearography, a speckle pattern method is based on the superposition of two laterally sheared images. Therefore, object points which are positioned in some distance from each other are superposed in the image plane. This shearography, one of NDT methods without contact, is able to inspect defects in pipelines and pressure vessels that are used in nuclear power plants. This is can inspect whole fields and has a low sensitivity to environmental noise. Because optical setting is very simple, it has a little exhaustion of time, cost and man power. And also it can find a defect position through real time monitoring of a part. This paper, finds out the relationship among shearing quantity image quality and defect size with this method.

  • PDF

DEM Estimation Using Two Stage Stereo Matching Method (2단계 스테레오 정합기법을 이용한 DEM 추정)

  • Nam, Chang-Woo;Woo, Dong-Min
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.12
    • /
    • pp.659-666
    • /
    • 2000
  • A stereo matching has been an important tool for reconstructing three dimensional terrain. By using stereo matching technique, DEM(Digital Elevaton Map) can be generated by the disparity from a reference image to a target image. Generally disparity map can be evaluated by matching the reference image to the target image and if the role of the reference and the target are interchanged, a different DEM can be obtained. In this paper, we propose a new fusion technique to estimate the optimal DEM by eliminating the false DEM due to occlusion. To detect the false DEM, we utilize two measure of accuracy: self-consistency and cross-correlation score. We test the effectiveness of the proposed methods with a quantitative analysis using simulated images. Experimental result indicate that the proposed methods show 24.4% and 33.1% improvement over either DEM.

  • PDF