• Title/Summary/Keyword: Digital Hospital

Search Result 1,338, Processing Time 0.027 seconds

Effect of Sex and Menopausal Age on Thickness and Density of Membranous Bone : Focused on Computed Tomography in Squamous Portion of Temporal Bone (성별과 폐경기 나이가 막성골의 두께와 밀도에 미치는 영향 : 측두골 비늘부위 전산화단층영상을 중심으로)

  • Ji, Myeong-Hoon;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.211-218
    • /
    • 2021
  • The purpose of this study was to investigate the effect of sex and menopausal age on the thickness and density of squamous portion of the temporal bone as the membranous bone. Patients who visited a general hospital in Chungnam and had a computed tomography (CT) examination of the head. A retrospective study was conducted with 120 subjects (30 men under 55 years old, 30 men over 56 years old, 30 women under 55 years old, and 30 women over 56 years old). Axial images of the squamous portion in the temporal bone were obtained from CT of the head. For this image, a slice sensitive profile (SSP) was acquired with an image analysis program and these were evaluated. The thickness was measured by using a digital ruler to measure the full width at half maximum (FWHM) of the SSP, and the density was measured in hounsfield unit (HU). These by gender were measured to be about 0.5 mm thinner in the temporal bone in men than in women, and there was a significant difference. The density was measured to be about 200 HU higher in women than in men of it, and there was a significant difference. As a result, it in women was thicker and had a lower density. The thickness of it in men and women over 56 years of age was 0.8 mm or more thicker in women and less than 400 HU in density. As a result, the women group over the age of 56 showed a distinct increase in thickness and decrease in density, different from other target groups. It is expected that the results of this study could be used as basic data for a new bone density measurement site study.

Theory Review for Understanding Flow Experience in Occupational Therapy (작업치료에서 몰입경험 이해를 위한 이론적 고찰)

  • Lee, Jeong-Hoon;Park, Ji-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.10 no.3
    • /
    • pp.71-81
    • /
    • 2021
  • Introduction : The purpose of this article was to introduce the theory of flow experience to occupational therapy for various therapeutic interventions to improve the subject's physical function, activity, and participation. Review : To understand the flow experience in occupational therapy, this study summarized the concept and characteristics of the flow experience, the stages and the scientific characteristics of the brain, measurement methods, and related studies through a review of domestic and foreign literature. In occupational therapy, the subject's flow experience can be defined as 'a psychological state in which the subject is completely flow in the therapeutic activity he is doing while forgetting the passage of time'. Subjects perceived a clear goal for the task and experienced engagement when the challenge was balanced with a high level of skill. In a previous study, positive changes in attention and concentration, executive function, upper extremity function, and performance of daily living activities were confirmed in subjects who encountered the flow experience. Conclusion : If the subject's flow experience in various therapeutic interventions in domestic occupational therapy is considered, the treatment effects will be further promoted.

Evaluation of Environmental Contamination and Disinfection Effects in Patient Rooms with Carbapenem-Resistant Enterobacteriaceae Using ATP Measurements and Microbial Cultures (ATP 측정과 미생물 배양검사를 이용한 카바페넴내성장내세균 보유환자 병실 환경 오염 및 환경 소독 효과 평가)

  • Kim, Ji Eun;Jeong, Jae Sim;Kim, Mi Na;Park, Eun Suk
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.4
    • /
    • pp.339-346
    • /
    • 2021
  • Purpose: To determine the extent of environmental contamination and the effect of disinfection around patients with carbapenem-resistant Enterobacteriaceae (CRE) using adenosine triphosphate (ATP) measurements and microbial culture tests. Methods: The subjects of this study were 10 patients hospitalized in a single room due to CRE from April 13 to 21, 2021. One hundred and sixty samples were collected using cotton swabs from the patients' environment including the surface and drain of sinks and toilet seats before and after disinfection of the room after discharge. Twenty-one samples were collected from the nurses' personal digital assistants (PDAs), keyboards, and computer mice before disinfection. The relative light units (RLUs) and CRE colony-forming units (CFU) of 181 samples were measured using ATP test equipment and chrome agar plates, respectively. Results: The highest RLUs were measured at the sink drains before and after disinfection. Four CRE samples from the sink drains (2), sink surface (1), and toilet bowl (1) before disinfection were cultured. Based on the failure criteria (≥ 250 RLU/cm2 and ≥ 1 CFU/100 cm2), 90 % and 50 % of the samples from the drain exceeded the failure criteria before and after disinfection, respectively. In the culture tests, CRE was not detected after disinfection. Conclusion: According to the RLU and CFU measurements of drain samples, disinfection was not effective. Thus, improvements in the disinfection methods of drains, as well as more efficient and systematic environmental decontamination and disinfection evaluation tools, are needed to accurately evaluate the effectiveness of disinfection in various places.

Volumetric analysis of normal condyles and those with disc displacement with reduction in the Indonesian population: A CBCT study

  • Nawawi, Azkya Patria;Rikmasari, Rasmi;Kurnikasari, Erna;Oscandar, Fahmi;Lita, Yurika Ambar
    • Imaging Science in Dentistry
    • /
    • v.52 no.1
    • /
    • pp.103-108
    • /
    • 2022
  • Purpose: Disc displacement can cause resorption of the head of the condyle and affect its volume. This study analysed the volume of normal condyles and those with disc displacement with reduction (DDR) in cone-beam computed tomography (CBCT) scans from the Indonesian population. Materials and Methods: This study analysed 56 condyles (26 normal and 30 with DDR) from patients who visited the Oral and Maxillofacial Radiology Unit after being referred from the Prosthodontics Unit at Dental Hospital Universitas Padjadjaran from December 2020 to February 2021. Samples were divided into 2 groups (normal and DDR left and right-side condyles) based on the DC/TMD Axis 1 form through the clinical examination results. Both sample groups were exposed to CBCT radiation. The CBCT imaging results in the Digital Imaging and Communications in Medicine format were exported to the open-source ITK-SNAP format to determine condyle volume. Volumetric data from the cortical and trabecular areas of the right or left side condyles were arranged by sex. The independent t-test was used to determine the significance of differences with IBM SPSS version 21.0. Intra- and inter-observer reliability and validity were tested before determining the volume of the condyles. Results: Normal condyles and DDR condyles showed significant differences in volume (P<0.05). Significant differences were also seen in cortical (P=0.0007) and trabecular (P=0.0045) volumes. There was a significant difference in condylar volume based on sex. Conclusion: The normal condyle volume was significantly different from the DDR condyle volume in both sexes.

Analysis on Optimal Approach of Blind Deconvolution Algorithm in Chest CT Imaging (흉부 컴퓨터단층촬영 영상에서 블라인드 디컨볼루션 알고리즘 최적화 방법에 대한 연구)

  • Lee, Young-Jun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.145-150
    • /
    • 2022
  • The main purpose of this work was to restore the blurry chest CT images by applying a blind deconvolution algorithm. In general, image restoration is the procedure of improving the degraded image to get the true or original image. In this regard, we focused on a blind deblurring approach with chest CT imaging by using digital image processing in MATLAB, which the blind deconvolution technique performed without any whole knowledge or information as to the fundamental point spread function (PSF). For our approach, we acquired 30 chest CT images from the public source and applied three type's PSFs for finding the true image and the original PSF. The observed image might be convolved with an isotropic gaussian PSF or motion blurring PSF and the original image. The PSFs are assumed as a black box, hence restoring the image is called blind deconvolution. For the 30 iteration times, we analyzed diverse sizes of the PSF and tried to approximate the true PSF and the original image. For improving the ringing effect, we employed the weighted function by using the sobel filter. The results was compared with the three criteria including mean squared error (MSE), root mean squared error (RMSE) and peak signal-to-noise ratio (PSNR), which all values of the optimal-sized image outperformed those that the other reconstructed two-sized images. Therefore, we improved the blurring chest CT image by using the blind deconvolutin algorithm for optimal approach.

The effect of acute diaphragmatic breathing exercise using DiP Belt on diaphragm motion and forced vital capacity (딥벨트를 이용한 일회성 가로막 호흡운동이 가로막 움직임과 노력성 폐활량에 미치는 영향)

  • Lee, Jae Seok;Kang, Tae Wook
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.2
    • /
    • pp.57-65
    • /
    • 2022
  • Background: This study was to determine whether the diaphragmatic breathing exercise using a DiP Belt(Diaphragmatic Pressure Belt) is effective in increasing the diaphragmatic motion and forced vital capacity. Design: Pretest-Posttest design. Methods: A total of 44 subjects(15 male, 29 female) participated in this study. All subjects were measured the diaphragmatic motion with a sonography and the Forced Vital Capacity(FVC) was measured with a digital spirometer. After 4 weeks, the subjects were intervened the diaphragmatic breathing exercise using a DiP belt and were remeasured for diaphragm motion and FVC. Results: After exercise intervention, quiet breathing significantly increased with the change in diaphragmatic motion and showed a moderate effect size (p<.01, Cohen's d = -0.53). In addition, it was significantly increased in deep breathing and showed a high effect size (p<.001, Cohen's d = -1.32). The mean diaphragmatic contraction pressure increased, but there was no significant difference and the peak diaphragmatic contraction pressure increased significantly (p<.05). Both diaphragmatic contraction pressure showed small effect sizes (respectively Cohen's d = -0.28, -0.33). In spirometry, FVC, Forced Expiratory Volume in 1 second (FEV1), and FEV1/FVC% all increased, but there was no significant difference. Only peak expiratory flow increased significantly and showed a small effect size (p<.05, Cohen's d = -0.41). Conclusion: The DiP belt diaphragmatic breathing exercise that the principle of visual feedback can correct diaphragm breathing in a short time, so it is a useful breathing exercise device that can help the diaphragm breathing exercise in the right way in clinical practice.

A Study on how to Utilize the DR System using Assistive Devices (보조기구를 이용한 DR System 활용 방법에 대한 연구)

  • Seon-Yeol, Seo;Jeong-Ho, Kim;Jin-Ok, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.115-122
    • /
    • 2023
  • The hip joint device is an important immobilization device for internal rotation in the diagnosis of bone density test, microfracture, and arthritis. These fixing mechanisms have limitations in maintaining reproducibility due to the use of Velcro. In this study, we developed an improved hip joint device and evaluated its usefulness. For 30 students enrolled in the Department of Radiology, we evaluated the reproducibility through medical imaging and the time required for positioning by applying the conventionaling and improved device. Changes over time were also evaluated. As a result, compared to the conventional device, the improved device showed a 32% reduction in positioning time and improved reproducibility by about 6.2 times. As for the amount of change over time, the positioning time increased in the conventional device, but decreased in the improved device, and the reproducibility of the conventional device was lower than that of the improved device. Through this, it can be said that the use of the improved device improved the image quality and reduced the radiologist's workload.

Angiographic Follow-Up for Small Ruptured Intracranial Aneurysm Treated by Endovascular Treatment : Follow-Up Plan and Long-Term Follow-Up Results

  • Kim, Tae Hyung;Ko, Jung Ho;Chung, Jaewoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.710-718
    • /
    • 2022
  • Objective : Although endovascular treatment for intracranial aneurysms is considered effective and safe, its durability is still debated. Also, few studies have described angiographic follow-up plan after endovascular treatment of intracranial aneurysm, especially in ruptured cases. Hence, we report the long-term results of follow-up angiography protocol. Methods : Radiological records of 639 cases of coil embolization with ruptured aneurysms from March 2003 to December 2016 were retrospectively reviewed. Patients who received treatment of a saccular aneurysm less than 7 mm resulted with near complete occlusion were included. Two hundred thirty-eight aneuryms which received the follow-up angiography at least once were enrolled. We classified four periods of follow-up as follows : post-treatment 1 year (defined as the first period), from 1 to 2 years (the second period), 2 to 5 years (the third period), and over 5 years (long-term). Results : We identified 14 cases (6.4%) of recurrence from 218 aneurysms in follow-up angiography in the first period. Among 143 aneurysms in the second period, five cases (3.5%) of recurrence were identified. There were no findings suspicious of recanalization in 97 patients in the third period. Of the total 238 cases, there were 19 recurrences, for a recurrence rate of 8.0%. Six (31.6%) out of 19 recurrences showed a tendency toward repeat recurrences even after additional treatment. Twenty-eight received long-term follow-up over 5 years and there was no recurrence. Conclusion : Most of the recurrence were found during the first and the second year. We suggest that at least one digital subtraction angiography examination may be necessary around post-treatment 2 years, especially in ruptured cases. If the angiographic results are favorable at 2 years post-treatment, long-term result should be favorable.

Assessment of Risk Factors for Postoperative Delirium in Older Adults Who Underwent Spinal Surgery and Identifying Associated Biomarkers Using Exosomal Protein

  • Baek, Wonhee;Lee, JuHee;Jang, Yeonsoo;Kim, Jeongmin;Shin, Dong Ah;Park, Hyunki;Koo, Bon-Nyeo;Lee, Hyangkyu
    • Journal of Korean Academy of Nursing
    • /
    • v.53 no.4
    • /
    • pp.371-384
    • /
    • 2023
  • Purpose: With an increase in the aging population, the number of patients with degenerative spinal diseases undergoing surgery has risen, as has the incidence of postoperative delirium. This study aimed to investigate the risk factors affecting postoperative delirium in older adults who had undergone spine surgery and to identify the associated biomarkers. Methods: This study is a prospective study. Data of 100 patients aged ≥ 70 years who underwent spinal surgery were analyzed. Demographic data, medical history, clinical characteristics, cognitive function, depression symptoms, functional status, frailty, and nutritional status were investigated to identify the risk factors for delirium. The Confusion Assessment Method, Delirium Rating Scale-R-98, and Nursing Delirium Scale were also used for diagnosing delirium. To discover the biomarkers, urine extracellular vesicles (EVs) were analyzed for tau, ubiquitin carboxy-terminal hydrolase L1 (UCH-L1), neurofilament light, and glial fibrillary acidic protein using digital immunoassay technology. Results: Nine patients were excluded, and data obtained from the remaining 91 were analyzed. Among them, 18 (19.8%) developed delirium. Differences were observed between participants with and without delirium in the contexts of a history of mental disorder and use of benzodiazepines (p = .005 and p = .026, respectively). Tau and UCH-L1-concentrations of urine EVs-were comparatively higher in participants with severe delirium than that in participants without delirium (p = .002 and p = .001, respectively). Conclusion: These findings can assist clinicians in accurately identifying the risk factors before surgery, classifying high-risk patients, and predicting and detecting delirium in older patients. Moreover, urine EV analysis revealed that postoperative delirium following spinal surgery is most likely associated with brain damage.

Effect of Whole Body Vibration Training on Proprioception and Tactile in Spastic Cerebral Palsy (전신진동 자극 훈련이 경직형 뇌성마비 아동의 고유수용감각 및 촉각에 미치는 영향)

  • Yun, Hye-Lyeong;Lee, Eun-Ju
    • PNF and Movement
    • /
    • v.20 no.1
    • /
    • pp.103-113
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the effects of whole-body vibration stimulation on proprioception and tactile in patients with spastic cerebral palsy. Methods: This study was conducted on 9 children diagnosed with spastic cerebral palsy. Of the single case study methods, the ABAB design was employed in this study. Out of a 12-week study period, three weeks were allocated to each of two baseline periods and two intervention periods. The exercise was performed twice a week for 30 minutes. A general trunk stabilization exercise was performed during the baseline period and a trunk stabilization exercise accompanied with whole-body vibration was performed during the intervention period. Evaluation was performed five times in total: before the experiment, after baseline 1, after intervention 1, after baseline 2, and after intervention 2. To determine the effect of the exercise method, a skin sensory evaluation tool (monofilament kit) and a trunk proprioception sensor (digital dual inclinometer) were used. To compare the effects of the exercises at baseline and after intervention, an analysis of variance on repeated measures (repeated ANOVA) was performed to analyze the data. Results: The results showed that there were statistically significant increases from baseline in the means of proprioception and tactile during the intervention period with whole-body vibration (p <.05). Conclusion: Whole-body vibration can be proposed as an effective intervention method for improving the proprioception and tactile in children with spastic cerebral palsy, and this exercise method is expected to be actively used in clinical practice.