• 제목/요약/키워드: Digital Disease

Search Result 508, Processing Time 0.025 seconds

A Preliminary Study on State Responsibility for Establishment and Protection of Information and Telecommunication Infrastructure in COVID-19 Pandemic (코로나19 사태에서 국가의 정보통신기반 구축·보호 책임에 대한 시론적 고찰)

  • Park, Sangdon
    • Journal of Digital Convergence
    • /
    • v.18 no.8
    • /
    • pp.49-54
    • /
    • 2020
  • COVID-19 pandemic is an opportunity to recognize the necessity of information and telecommunications infrastructure which is base of information and telecommunication. This paper discusses the importance of information and telecommunications infrastructure in COVID-19 pandemic and overview proper institutional measures to fulfill state responsibility for establishment and protection of the infrastructure through documentary survey and normative study with juristic consideration. Information and telecommunications infrastructure has critical functions to respond to the pandemic and is one of the key to make digital transformation. A state is responsible for establishment and protection of Information and telecommunications infrastructure. Institutional measures have significance for the state responsibility and they are formed by not only statute but also constitution with making state object provision for establishment and protection of Information and telecommunications infrastructure. This paper shows premise and direction of further studies on related individual legislation.

AN ASSESSMENT OF THE SHORT-TERM EFFECT OF PERIODONTAL FLAP SURGERY BY DIGITAL SUBTRACTION RADIOGRAPHY (계수공제영상 방사선 측정법을 이용한 치주판막술 후 치조골 변화의 평가)

  • Jin, Yoo-Nam;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.595-604
    • /
    • 1993
  • Since $Gr{\"{o}}nadhl$ et al introduced a digital subtraction radiography into periodontal dignosis in 1983, many reports using this system has aimed to assess the peroiodontal disease activity and the alveolar bone changes after periodontal treatment. The present study was performed to evaluate the usefulness of digital subtraction radiography for asessing an alveolar bone changes in 3 months after periodontal flap surgery. Serial intraral raiographs were taken from 5 normal subjects and 6 periodontally diseased patients using customized bite blocks attached to film holder in fxation device and digitized by image processing system(consisting of IBM 386, digital frame grabber, CCD camera, Image-pro II software). And the reference parameters were measured by pixel unit and compared with respective radiographs. The serial radiographs showed a little and statistically insignificant difference in reference paramenters. The conventional intraoral radiographs, the subtraction images and the clor enhanced subtraction images were reviewed by 4 examiners and the examiner's agreement rates were compared. The subtraction images and its color enhanced images showed higher examiner's agreement rate than the conventional radiographs. And the propotions of sites diagnosed with bone loss or gain after periodontal surgery were highter in the subtraction images and its color enhanced images than in the conventional radiographs. Especially, in color enhanced images, the unber of bone agin sites tended to increase according to post-surgery periods. These results indicate that projection geometry could be standardized with the divice used in this study, and the subtraction radiography may be useful to assess an alveolar bone changes after periodntal flap surgery.

  • PDF

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

Mild Cognitive Impairment Evaluation and Analysis System (경도인지 장애 평가 및 분석 시스템)

  • Choi, Sung-Hoon;Joo, Moon-Il;Yang, Yeong-Ae;Kim, Hee-Cheol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.11
    • /
    • pp.2054-2060
    • /
    • 2016
  • As the aging society is accelerated, the population with dementia grows significantly faster. Because there is no complete cure of dementia, it is of great importance to detect the disease at a very early stage and prevent its fast aggravation through evaluation of MCI(Mild Cognitive Impairment) which happens before dementia. The current assessment of MCI conducts only in the form of hand-written data and by 1:1 face to face communication between the subjects and the examiners. Due to this, both examiners' fatigue rate and evaluation error rate increase. Further, there are some limitations in utilizing and analyzing data collected. Against the problems, therefore, there is a need to develop a computerized system by which MCI is assessed, and the results are saved and analyzed. This paper presents the development of such a system enabling MCI evaluation, its related data collection and analysis.

Exercise With a Novel Digital Device Increased Serum Anti-influenza Antibody Titers After Influenza Vaccination

  • Jun-Pyo Choi;Ghazal Ayoub;Jarang Ham;Youngmin Huh;Seung Eun Choi;Yu-Kyoung Hwang;Ji Yun Noh;Sae-Hoon Kim;Joon Young Song;Eu Suk Kim;Yoon-Seok Chang
    • IMMUNE NETWORK
    • /
    • v.23 no.2
    • /
    • pp.18.1-18.15
    • /
    • 2023
  • It has been reported that some exercise could enhance the anti-viral antibody titers after vaccination including influenza and coronavirus disease 2019 vaccines. We developed SAT-008, a novel digital device, consists of physical activities and activities related to the autonomic nervous system. We assessed the feasibility of SAT-008 to boost host immunity after an influenza vaccination by a randomized, open-label, and controlled study on adults administered influenza vaccines in the previous year. Among 32 participants, the SAT-008 showed a significant increase in the anti-influenza antibody titers assessed by hemagglutination-inhibition test against antigen subtype B Yamagata lineage after 4 wk of vaccination and subtype B Victoria lineage after 12 wk (p<0.05). There was no difference in the antibody titers against subtype "A." The SAT-008 also showed significant increase in the plasma cytokine levels of IL-10, IL-1β, and IL-6 at weeks 4 and 12 after the vaccination (p<0.05). A new approach using the digital device may boost host immunity against virus via vaccine adjuvant-like effects.

A Lifelog Posture Estimation Web Program Using Arduino and FSR402 Sensors

  • Ae-Ri Jung;Min-Seok Song;Hyun-Seo Shin;Young-Bok Cho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.11
    • /
    • pp.251-258
    • /
    • 2024
  • In this paper, we propose a posture correction system using the Arduino FSR402 sensor and Skeleton Keypoint artificial intelligence model. In anticipation of the introduction of AI Digital Textbook (AIDT), which will be fully implemented from 2025 under the 2022 curriculum reform, the need for research to raise awareness of the risk of digital diseases among children and adolescents and to prevent them is emphasized. The proposed system learns the correct posture for each user based on their life log information and helps them maintain good posture by determining whether they are using a smart device correctly and guiding them. In particular, for children and adolescents who experience physical changes, it has the advantage of learning the changed body information from the Skeleton Keypoint artificial intelligence model to guide the appropriate posture, and it can be confirmed that the sensor's measurement value operates normally within the error range (average error 2.53%) in measuring the correct posture for each user.

ANALYSIS ON THE PREDICTOR OF DISEASE PROGRESSION IN REFRACTORY PERIODONTITIS (난치성 치주염의 질환진행 예견 인자에 관한 분석)

  • Lee, Hae-Joon;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.1
    • /
    • pp.109-126
    • /
    • 1993
  • Refractory periodontitis manifest progressive attachment loss in a rapid and unrelenting manner regardless of the type or frequency of therapy applied. The purpose of this study was ta evaluate the relation between the level of cytokines in GCF and periodontopathic microflora with disease activity of refractory periodontitis. Selection of patients with refractory periodontitis (7 males, 3 females) were made by long term clinical observation including conventional clinical history and parameters. Teeth that showed pocket depth greater than 6mm were selected as sample teeth. Subjects were examined at baseline and after 3 months. Prior to baseline test, individual acrylic stent was fabricated. Reference grooves were made on each sample tooth site. Pocket depth and attachment loss were measured by Florida Probe. Gingival index was measured at 4 sites each sample teeth. Disease activity was defined as attachment loss of ${\ge}$ 2.1mm, as determined by sequential probing and tolerance method. The pattern and amount of alveolar bone resorption was observed with quantitative digital subtraction image processing radiography. Morphological analysis of subgingival bacteria was taken by phase contrast microscopy. Predominant cultivable bacterial distribution and frequency were compared between disease-active and disease-inactive site using immunofluorescence microscopy and selective microbial culturing. Levels of $interleukin-l{\beta}$, 2, 4, 6 and $TNF-{\alpha}$ in GCF and blood serum sample were quantified by ELISA. In active sites, P. intermedia was significantly increased to compare with inactive site. $IL-1{\beta}$, IL-2, IL-6 and $TNF-{\alpha}$ in GCF were increased in active sites and IL-2 in serum was increased in active patients significantly. Alveolar bone loss in active site was correlated with $IL-1{\beta}$, IL-2 in GCF. And loss of attachment in active site was correlated with IL-2 in GCF. These results demonstrate that IL-2 in serum, $IL-1{\beta}$, IL-2, IL-6 and $TNF-{\alpha}$ in GCF, P, intermedia might be used as possible predictors of disease activity in refractory periodontitis before it is clinically expressed as attachment loss and quantitative alveolar bone change.

  • PDF

Image Analysis Using Digital Radiographic Lumbar Spine of Patients with Osteoporosis (골다공증 환자의 Digital 방사선 요추 Image를 이용한 영상분석)

  • Park, Hyong-Hu;Lee, Jin-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.362-369
    • /
    • 2014
  • This study aimed to propose an accurate diagnostic method for osteoporosis by realizing a computer-aided diagnosis system with the application of the statistical analysis of texture features using digital images of lateral lumbar spine of patients with osteoporosis and providing reliable supplementary diagnostic information by model experimental research for early diagnosis of diseases. For these purposes, digital images of lateral lumbar spine of normal individuals and patients with osteoporosis were used in the experiments, and the values of statistical texture features on the set ROI were expressed in six parameters. Among the texture feature values of the six parameters of osteoporosis, the highest and lowest recognition rates of 95 and 80% were shown in average gray level and uniformity, respectively. Moreover, all the six parameters showed recognition rates of over 80% for osteoporosis: 82.5% in average contrast, 90% in smoothness, 87.5% in skewness, and 87.5% in entropy. Therefore, if a program developing into a computer-aided diagnosis system for medical images is coded based on the results of this study, it is considered possible to be applied to preliminary diagnostic data for automatic detection of lesions and disease diagnosis using medical images, to provide information for definite diagnosis of diseases, to diagnose by limited device, and to be used to shorten the time to analyze medical images.

Study on the Exposure Dose(mAs) and acquisition Image set up Density Display and Sensitivity of control Panel for the Digital Flat-Panel-Detector (디지털 평판형 검출기에서 Control Panel의 Density Display와 Sensitivity 설정이 조사선량(mAs)과 획득영상에 미치는 영향에 관한 연구)

  • Kim, Byung-Ki;Kim, Sang-Keun;Cha, Seon-Hwa;Choi, Jun-Gu;Lee, Jun;Kim, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Sun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.2
    • /
    • pp.17-21
    • /
    • 2007
  • The purpose to recognize change of average pixel value of acquisition image by control panel's density and right set up method of speed (sensitivity) and exposure dose(mAs) change that dose in purpose digital flatpanel-detector. X -ray generator DHF-158H2(Hitachi, Japan). Detector CXDI 4OG(Canon, Japan), 12 : 1 grid and exposure ray 135 kVp, 250 mA, 10 ms. focus-detector distance 180 cm and used AEC mode. DICOM reflex analysis program used image J that is digital reflex analysis program that offer in United States America National Health Center(National Institutes of Health : NlH) phantom used chest phantom(Anthromorphic : Flukebrome.medicaI USA). An experiment chest phantom that consist by formation equivalence material use because density value( -3${\sim}$+3) in X-ray control panel and seep that is speed step(slow, medium, fast) each control experimentalize. image analysis reflex neted through an experiment using image j each image compare. These was change in dose according to slow, medium, fast and density's change in an experiment result. According to detector sensitivity and density condition set, dose was relationship dissimilarity 500% from 200%. The dose came highest when is density +3 to slow. and dose more increases gray scale's extent could know that rise. Could know whether how equipment set is important through this experiment. cause of disease which change by digital radiography system forward is thought to increase more, it is considered that suitable education by this and continuous interest about equipment need absolutely.

  • PDF

Discrimination of Spinal Deformity Employing Discriminant Analysis on the $Moir\acute{e}$ Images

  • Kim, Hyoung-Seop;Ishikawa, Seiji;Otsuka, Yoshinori;Shimizu, Hisashi;Nakada, Yasuhiro;Shinomiya, Takashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1990-1993
    • /
    • 2003
  • In this paper, we propose a technique for automatic spinal deformity detection from $moir\acute{e}$ topographic images. Normally the $moir\acute{e}$ stripes show symmetry as a human body is almost symmetric. According to the progress of the deformity of a spine, asymmetry becomes larger. Numerical representation of the degree of asymmetry is therefore useful in evaluating the deformity. First, displacement of local centroids and difference of gray values are evaluated statistically between the left- and the right-hand side regions of the $moir\acute{e}$ images with respect to the extracted middle line. We classify the moire images into two categories i.e., normal and abnormal cases from the features, employing discriminant analysis. An experiment was performed employing 1,200 $moir\acute{e}$ images and 85% of the images were classified correctly.

  • PDF