• Title/Summary/Keyword: Digital Detector

Search Result 554, Processing Time 0.031 seconds

A Study on Seabed Interpretation System Using Supersonic Waves (초음파를 이용한 해저면 판독 시스템에 관한 연구)

  • 김재갑;김원중;황두진
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.2
    • /
    • pp.385-391
    • /
    • 2001
  • In this study, we will develop the sea surface interpretation system that can aware the target in the bottom of the sea. we will setup the database whose records would be the signal patterns of formation about mud, sand, rock and sea shell achieved by using supersonic. then we will convert analog signal received in fish detector to digital one using A/D converter So we can process and analyze this signal pattern then compare it to the one in our Database at the real time to identify the target in the bottom of the sea. After enough times of experiments from the background of the results that have been achieved from many studies(including a water tank experiment and a field investigation), we can aware the exact information of the sediment and the sand in the sea. By analyzing the first, second and third signal of the supersonic characters reflected from the body of a fish categorized by its family and from the body of shellfish, muddy sand, sand and rocks, We will develop the sea surface decipherment system which abstracts the first signal that shows the target in the bottom of the sea and makes the second and third signals filtering.

  • PDF

A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation (XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구)

  • Gang, Dong-Sik;Seon, Jong-Ho;Kim, Wi-Yeong;Lee, Hong-Sik;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.

Edge Strength Hough Transform : An Improvement on Hough Transform Using Edge Strength (경계선 강도를 이용한 허프 변환의 개선)

  • Heo, gyeong-Yong;Lee, Kwang-Eui;Woo, Young-Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.11
    • /
    • pp.2055-2061
    • /
    • 2006
  • The detection of geometric primitives from a digital image is one of the basic tasks in computer vision area and the Hough transform is a well-known method for detecting analytical shape represented by a number of free parameters. However the basic property of the Hough transform, the one-to-many mapping from an image space to a Hough space, causes the innate problem, the sensitivity to noise. In this paper, we proposed Edge Strength Hough Transform which uses edge strength to reduce the sensitivity to noise and proved the insensitivity using the ratio of peaks in a Mough space. We also experimented the proposed method on lines and got small number of peaks in a Hough space compared to traditional Hough transform, which supports the noise insensitivity of the proposed method.

A Study on Current Control using a Novel SVM-Based Hysteresis Controller in D-STATCOM (SVM 기반 히스테리시스 제어기를 이용한 D-STATCOM 전류 제어에 관한 연구)

  • Choi Jeong-Hye;Shin, Eun-Chul;Yoo, Ji-Yoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.293-301
    • /
    • 2006
  • This paper proposes a control algorithm for STATic synchronous COMpensator(STATCOM), based on Space Vector Modulation(SVM) and Hysteresis Current Controller(HCC) techniques. STATCOM is used to reactive power compensation on a distribution network. The proposed algorithm utilizes the advantages of the fast dynamic response of the hysteresis current control and the reduced switching number of the SVM scheme. The controller determines a set of space vectors from a region detector and applies a space vector. A set of space vectors including the zero vector, to reduce the number of switching, is determined from output signals of two hysteresis comparators. The presented control system was tested with digital simulation in the Borland C++ program and demonstrate the advantage of the proposed hysteresis current controller.

Comparison of SPECT Images with $^{99m}Tc$ Collimators ($^{99m}Tc$용 콜리메타의 성능과 SPECT 화상의 영향)

  • Lee, Man-Koo;Lee, Jeong-Ok;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.35-40
    • /
    • 2001
  • Performance of SPECT imaging systems which use a rotating gamma camera, are affected by characteristics of the detector-collimator assembly, the data acquisition method, and the filter used in imaging reconstruction. The purpose of this study Is to examine image qualifies of SPECT with different types of low energy collimators. The SPECT imaging system in this study is a digital gamma camera system GCA-901A(Toshiba) and a data processing unit Scintipac-700(Shimadzu). The four types of collimators compared are UHR(ultra high resolution), LEHR(low energy high resolution), LEGP(low energy general purpose), and I-123 PAR(Parallel), with 0.27, 0.66, 1.00, and 2.06 relative sensitivity, respectively. In this case of the same collimators, the spatial resolutions measured in the slice plane showed a slight difference in the FWHM values(mean values of UHR, LEHR, LEGP, and I-123 PAR were 11.3 mm, 13.6 mm, 15.8 mm, and 20.4 mm, respectively) between the center and the circumference of the field of view, in the radial direction, but a large difference in the tangential direction, with lower FWHM values(values of UHR, LEHR, LEGP, and I-123 PAR were 8.4 mm, 8.7 mm, 9.3 mm, and 10.8 mm at 12 cm from the center, respectively). In comparison of SPECT images with the four types of collimators, except for the I-123 PAR collimator, image qualities of UHR, LEHR, and LEGP collimators showed only a slight difference. From the point of for, it is expected that the LEGP collimator would be suitable for SPECT imaging with $^{99m}Tc$.

  • PDF

Development of Tobacco Ripeness Grading Meter Using the Color Sensor (칼라센서를 이용한 담배 완숙도의 식별장치 개발)

  • 이대원;이용국
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 1994
  • A tobacco ripeness grading meter was designed and constructed using the color sensor, its performance was evaluated. A degree of ripeness grading of a leaf is very closely related to the measured tobacco leaf color. Measuring the small amount of the reflectance precisely depends on the apparatus including color sensor, light source, detector sensitivity, and geometric characteristics of appratus. To analyze and minimize the variational effects, experiments to select the proper condition were performed. Because of the combined effect mentioned above, the system has some variation on its response. Basis on the results of the experiments, prototype was developed and interfaced to a computer system. The main components of prototype included a tungsten lamp as a light source, Amorphous full color sensor with three filters, regulated D.C. power supply, OP - AMP(741 TC) for amplification, AR - B3001 board for interfacing to a computer with analog to digital conversion, and a compatible IBM PC XT computer. The experimental results of the developed ripeness tobacco leaf measurement system are summarized as following: [1] The output readings of ripeness grade meter for tobacco leaf, which is based on harvesting time, showed the apparent difference in variety of different quality. It was considered suitable that three filters(red, green, blue) in Amorphous full color sensor could be used in four different ripeness degree measurement of tobacco leaf. [2] The output readings of ripeness grade meter for tobacco leaf, which is based on government procurement, showed apparent difference in variety of different quality. Tobacco leaf varieties to stalk position are divided into tips, leaf, cutters, and primings, It is considered suitable that only red filter in the sensor could be used to classify the grade of tobacco leaf within the same kind tobacco stalk. However, the ripeness grade meter was not adequate to classify all the tobacco grades in the four different tobacco leaves.

  • PDF

Serial line multiplexing method based on bipolar pulse for PET

  • Kim, Yeonkyeong;Choi, Yong;Kim, Kyu Bom;Leem, Hyuntae;Jung, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3790-3797
    • /
    • 2021
  • Although the individual channel readout method can improve the performance of PET detectors with pixelated photo-sensors, such as silicon photomultiplier (SiPM), this method leads to a significant increase in the number of readout channels. In this study, we proposed a novel multiplexing method that could effectively reduce the number of readout channels to reduce system complexity and development cost. The proposed multiplexing circuit was designed to generate bipolar pulses with different zero-crossing points by adjusting the time constant of the high-pass filter connected to each channel of a pixelated photo-sensor. The channel position of the detected gamma-ray was identified by estimating the width between the rising edge and the zero-crossing point of the bipolar pulse. In order to evaluate the performance of the proposed multiplexing circuit, four detector blocks, each consisting of a 4 × 4 array of 3 mm × 3 mm × 20 mm LYSO and a 4 × 4 SiPM array, were constructed. The average energy resolution was 13.2 ± 1.1% for all 64 crystal pixels and each pixel position was accurately identified. A coincidence timing resolution was 580 ± 12 ps. The experimental results indicated that the novel multiplexing method proposed in this study is able to effectively reduce the number of readout channels while maintaining accurate position identification with good energy and timing performance. In addition, it could be useful for the development of PET systems consisting of a large number of pixelated detectors.

Should Cerebral Angiography Be Avoided within Three Hours after Subarachnoid Hemorrhage?

  • An, Hong;Park, Jaechan;Kang, Dong-Hun;Son, Wonsoo;Lee, Young-Sup;Kwak, Youngseok;Ohk, Boram
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.526-535
    • /
    • 2019
  • Objective : While the risk of aneurysmal rebleeding induced by catheter cerebral angiography is a serious concern and can delay angiography for a few hours after a subarachnoid hemorrhage (SAH), current angiographic technology and techniques have been much improved. Therefore, this study investigated the risk of aneurysmal rebleeding when using a recent angiographic technique immediately after SAH. Methods : Patients with acute SAH underwent immediate catheter angiography on admission. A four-vessel examination was conducted using a biplane digital subtraction angiography (DSA) system that applied a low injection rate and small volume of a diluted contrast, along with appropriate control of hypertension. Intra-angiographic aneurysmal rebleeding was diagnosed in cases of extravasation of the contrast medium during angiography or increased intracranial bleeding evident in flat-panel detector computed tomography scans. Results : In-hospital recurrent hemorrhages before definitive treatment to obliterate the ruptured aneurysm occurred in 11 of 266 patients (4.1%). Following a univariate analysis, a multivariate analysis using a logistic regression analysis revealed that modified Fisher grade 4 was a statistically significant risk factor for an in-hospital recurrent hemorrhage (p=0.032). Cerebral angiography after SAH was performed on 88 patients ${\leq}3$ hours, 74 patients between 3-6 hours, and 104 patients >6 hours. None of the time intervals showed any cases of intra-angiographic rebleeding. Moreover, even though the DSA ${\leq}3$ hours group included more patients with a poor clinical grade and modified Fisher grade 4, no case of aneurysmal rebleeding occurred during erebral angiography. Conclusion : Despite the high risk of aneurysmal rebleeding within a few hours after SAH, emergency cerebral angiography after SAH can be acceptable without increasing the risk of intra-angiographic rebleeding when using current angiographic techniques and equipment.

A Case Study of Application of Exposure Index in Computed Radiography by Using Human Chest Phantom (인체 흉부 모형 팬텀을 이용한 컴퓨터방사선영상에서 노출지수의 적용 사례 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.533-538
    • /
    • 2018
  • As the use of digital radiographic system has been expanded, there are some concerns an increase about in patient of radiation dose. Therefore, International Electro-technical Commission (IEC) has been proposed a standard foe exposure index (EI). In this study, the EI was measured on human chest model using computed radiography (CR). Radiation quality used RQA5 of IEC62494-1. After acquiring the chest anterior posterior image (Chest AP) by using the phantom, the EI was obtained by applying the system response. In this study, we have analyzed the images with the detector size (Full filed ROI) and the optimized image (Fit filed ROI). The EI increased proportionally with radiation dose increase. Due to the discrete increase in pixel value, the EI showed an exponential increase. The discrete increase in noise equivalent quanta (NEQ) resulted in a discrete increase in the EI. The EI of the two images used in this study increased with increasing NEQ but showed different increments. For the measurement of the EI, IEC standards must be followed. The EI should be used as an index to evaluate the image quality for quality control of X-ray image rather than as an indicator of exposure dose. When calculating the EI, the system response should be applied depending on whether or not the grid is used. The size of the field should be obtained by including only the necessary parts.

The investigation of a new fast timing system based on DRS4 waveform sampling system

  • Zhang, Xiuling;Du, Chengming;Chen, Jinda;Yang, Herun;kong, Jie;Yang, Haibo;Ma, Peng;Shi, Guozhu;Duan, limin;Hu, Zhengguo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.432-438
    • /
    • 2019
  • In the study of nuclear structure, the fast timing technique can be used to measure the lifetime of excited states. In the paper, we have developed a new fast timing system, which is made up of two $LaBr_3:Ce$ detectors and a set of waveform sampling system. The sampling system based on domino ring sampler version 4 chip (DRS4) can digitize and store the waveform information of detector signal, with a smaller volume and higher timing accuracy, and the waveform data are performed by means of digital waveform analysis methods. The coincidence time resolution of the fast timing system for two annihilation 511 keV ${\gamma}$ photon is 200ps (FWHM), the energy resolution is 3.5%@511 keV, and the energy linear response in the large dynamic range is perfect. Meanwhile, to verify the fast timing performance of the system, the $^{152}Gd-2_1^+$ state form ${\beta}^+$ decay of $^{152}Eu$ source is measured. The measured lifetime is $45.3({\pm}5.0)ps$, very close to the value of the National Nuclear Data Center (NNDC: $46.2({\pm}3.9)ps$). The experimental results indicate that the fast timing system is capable of measuring the lifetime of dozens of ps. Therefore, the system can be widely used in the research of the fast timing technology.