• Title/Summary/Keyword: Digital Contrast Technology

Search Result 134, Processing Time 0.033 seconds

Usefulness of an Auxiliary Tool for Hand Radiography by Using 3D Printing (3D 프린팅을 이용한 손 엑스선 검사 보조도구의 유용성)

  • Ji-Won Kim;Bon-Yeoul Koo
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.485-491
    • /
    • 2023
  • As an auxiliary tool for fixing the patient's posture when taking an X-ray, sponges with high radiolucencies are laminated in various thicknesses. This study aimed to evaluate the usefulness of an auxiliary tool for hand oblique projection X-ray by manufacturing it with a uniform thickness by 3D printing and comparing it with existing sponge tools. In the auxiliary tool, radiolucency was measured at the stairs where each finger was located, and pixel information values were compared in the digital imaging and communications in medicine(DICOM) image. Contrast to noise ratio(CNR) and signal to noise ratio(SNR) were compared by shooting the hand phantom and the auxiliary tool together. As the thickness of the sponge tool increased, radiolucency decreased by 15.52% and pixel information value increased by 20.61%. The transmittance of the 3D printing tool increased by 0.82%, and the pixel information value differed by 5.66%. CNR and SNR increased by 20.03% and 22.42% in 3D printing compared to existing sponge tools. while taking hand oblique projection, maintaining the thickness of the auxiliary tool uniformly through 3D printing maintains high radiolucency and minimal impact on medical images, and increases CNR and SNR, making it useful as an auxiliary tool for taking hand oblique projection.

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.

Elliptical Centric Techniques and Tricks About the Usefulness of the Clinical Application (Elliptical Centric과 TRICKS 기법의 임상 적용에 관한 유용성 연구)

  • Kim, Sae-Ssak;Goo, Eun-Hoe;Dong, Kyung-Rae;Kweon, Dae-Chel;Lee, Jae-Seung;Cho, Jae-Hwan;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • To prospectively determine the diagnostic performance a combination of standard bolus-chase magnetic resonance (MR) angiography and MR angiography with time-resolved imaging of contrast kinetics (TRICKS) for depicting severity of the head and neck vascular diseases. Over a period of two months, A total of 100 patients(average ages : $50{\pm}8$, male : 60, female : 40) with head and neck vascular diseases were performed on the GE excite 3.0 T units with 8-channel head coil and 4-channel NV coil. Imaging parameters for a typical study were as follow: SBC(TR/ TE/ FA/ SliceThicken./ Slab/ Freq./ FOV/ BW/Scan Time) = 5.4/ min/ 30/ 2/ zip2/ 70/ $224{\times}448$/ 30/ 62.50/ 28, TRICKS(TR/ TE/ FA/ Slice Thicken/Slab/ Freq./ FOV/ BW/ Temp Res./ Scan Time = 3.6/ min/ 25/ 4/ 30/ $160{\pm}384$, zip512/ 30/ 100/ 1 to 1.5/ 23). The analysis of all MR images, which have respect-ively classified two techniques into some diseases. The results of the former were divided into two groups(SBC, TRICKS)with 4 grading of two reader, respectively. Wilcoxon signed rank test was used to determine if a significant difference between imaging techniques existed(p < 0.05). In 33 of 100 patients, arterio-venous malformation was 11% at TRICKS, subclavian vein stenosis : 8%, fistular sinus : 4%, jugular vein stenosis:6%, Middle Cerebral Artery bypass surgery : 4%, p < 0.05). The rest of 67 patients were considered as the results of SBC(14% in the basilar artery stenosis, carotid stenosis : 16%, vertebral stenosis : 17%, central neuro-cytoma : 5%, meningioma : 5%, Not appliable : 10%, p < 0.05). Sensitivity and specificity of TRICKS MR angiography in SVS, FS, JVS, MCABS were improved compared with those at standard MR angiography. In SBS MR angiography which were improved in BAS, CS, VS, CN, Meningioma. In conclusion, TRICKS MR angiography of the SVS, FS, JVS, MCABS is superior to standard MR angiography regarding the number of diagnostic grading. The SBS MR angiography were improved in BAS, CS, VS, CN, Meningioma. and assessment of the degree of luminal narrowing on both TRICKS and SBS.

  • PDF

6G Technology Competitiveness and Network Analysis: Focusing on GaN Integrated Circuit Patent Data (6G의 기술경쟁력 및 네트워크 분석: GaN 집적회로 특허 데이터 중심)

  • Woo-Seok Choi;Jin-Yong Kim;Jung-Hwan Lee;Sang-Hyun Choi
    • Journal of Industrial Convergence
    • /
    • v.21 no.3
    • /
    • pp.1-15
    • /
    • 2023
  • Expectations for wireless communication technology are rising as a base technology that promotes innovation in various industries in line with the paradigm of digital transformation in the 21st century beyond the stage of being used only for communication service itself. In this study, in order to compare 6G technological competitiveness between Korea and leading countries, technological competitiveness was confirmed through PFS, CPP, and network analysis based on GaN Integrated Circuit patent data. Korea's 6G technological competitiveness was 0.62 in PFS and 3.93 in CPP, which were 32.8% and 19.9%, respectively, compared to leading countries. In addition, as a result of network analysis, the collaboration rate in the 6G field was 7.2%, and the collaboration ecosystem was very insufficient in most countries. In contrast, it was confirmed that Korea, unlike leading countries, has established a small-scale collaboration ecosystem linked by industry and academia. Thus, it is necessary to establish a strategy for 6G communication technology at the national level so that communication technology can be advanced based on a relatively well-established collaborative ecosystem.

Comparison and Analysis of Web Accessibility for the Korea, USA, and Japan's Broadcast Web Sites (한·미·일 지상파 방송사의 웹 접근성 비교·분석)

  • Park, Seong-Je;Kim, Yung-Keun;Kim, Jong-Weon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.19 no.4
    • /
    • pp.105-117
    • /
    • 2014
  • Acquisition of information through the broadcast media is essential for modern life and each broadcaster has progressed its service over the internet with the development of digital technology. Under this circumstance, this study presented the results which compared and analyzed the web accessibility evaluation for Korea, USA, and Japan's leading broadcaster web sites. According to the study results, there was no significant difference in the level of accessibility in all web sites of three countries, but accessibility compliance rate such as alternate text, skip-navigation of repeated region, and title was somewhat insufficient for Korean web sites. In addition, accessibility errors in the brightness contrast of the text contents, the run of the functions that a user doesn't have any intention, the clear statement of the default language, and the label provision were investigated. Therefore, Korean broadcasters should urgently improve and modify these errors and problems for effective web accessibility.

Model-Based Color- Image Halftoning Algorithm Using Dot-Pattern Database (도트 패턴 데이터 베이스를 이용한 모델 기반 칼라 영상 중간조 알고리즘)

  • Kim, Kyeong-Man;Song, Kun-Woen;Min, Gak;Kim, Jeong-Yeop;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.2
    • /
    • pp.208-217
    • /
    • 2001
  • Model-based color image halftoning method using dot-pattern database is proposed for low-resolution color image printing. Dot-pattern database used in the proposed method is based on Blue-Noise Mask. The database consists of dot-patterns constructed by circular dot-overlap model according to each color value. In halftoning procedure, input color value is reproduced as the dot-pattern selected to minimize the difference between the color values of the original image and those of the printed image. Also, the contrast sensitivity function as a human visual model is used to improve the perceived quality of the printed image in dot-pattern selection. Thus, the proposed method can substantially reproduce the color values of the pixels in original image and obtain better image quality. In the experiment, the proposed method has less ΔΕ/Sub ab/ between the original image in monitor and the printed one than that of ED and BNM halftoning. This result approves that the proposed method reproduces better image quality.

  • PDF

VirtualDub as a Useful Program for Video Recording in Real-time TEM Analysis (실시간 TEM 분석에 유용한 영상 기록 프로그램, VirtualDub)

  • Kim, Jin-Gyu;Oh, Sang-Ho;Song, Kyung;Yoo, Seung-Jo;Kim, Young-Min
    • Applied Microscopy
    • /
    • v.40 no.1
    • /
    • pp.47-51
    • /
    • 2010
  • The capability of real-time observation in TEM is quite useful to study dynamic phenomena of materials in a certain variable ambience. In performing the experiment, the choice of video recording program is an important factor to obtain high quality of movie streaming. Window Movie Maker (WMM) is generally recommended as a default video recording program if one uses "DV Capture" function in DigitalMicrograph$^{TM}$ (DM) software. However, the image quality does not often satisfy the condition for high-resolution microscopic analysis since the severe information loss in the final result occurs during the conversion process. As a good candidate to overcome this problem, Virtual-Dub is highly recommended since the information loss can be minimized through the streaming process. In this report, we demonstrated how useful VirtualDub works in a high-resolution movie recording. Quantitative comparison of the information quality between the images recorded by each software, WMM and VirtualDub, was carried out based on histogram analysis. As a result, the image recorded by VirtualDub was improved ~13% in brightness and ~122% in contrast compared with the image obtained by WMM at the same imaging condition. Remarkably, the gray gradation (meaning an amount of information) becomes wider up to ~115% than that of the WMM result.

A Study on the Mode of Address and Meaning Creation of Underlight in Broadcasting Lighting (방송조명에서 언더라이트의 표현 양식과 의미 창출에 관한 연구)

  • Kim, Young-Jin;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.21 no.5
    • /
    • pp.749-759
    • /
    • 2016
  • As image contents in broadcasting have been created in HDTVs and monitors have been commercialized, facial expression of objects in broadcasting lighting has become a very significant task. Figure modeling of objects in HDTVs requires smoother and cleaner video images owing to the expansion of precision of image expression by light. Lighting methods that enlighten characters in the digital generation have come to require a new change. Character modeling methods used on expression features of underlight are receiving attention for aesthetic expression of figures in HD images. Accordingly, the influence of underlight light source intensity, distance, and size on character modeling characteristics was experimentally measured and comparatively analyzed. The experiment results show that good results can be obtained only when the intensity is 17%∼25.5% in contrast to total brightness, distance is beyond 40cm, and the size is at least 20cm, to exhibit the optimum effect of underlight. This data will become material with high usage to gain smoother and cleaner images of characters in future high-quality images.

Tensile Tests for Copper Thin Foils by Using DIC Method (DIC 법을 이용한 구리박막의 인장시험)

  • Kim, Chung Youb;Song, Ji Ho;Park, Kyung Jo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.12
    • /
    • pp.1529-1534
    • /
    • 2012
  • In this study, tensile tests for 12-${\mu}m$-thick copper thin foils were performed by using the DIC method. The DIC method provided precise stress-strain curves for thin film materials, and a commercial inkjet printer can be simply and effectively used for printing speckle patterns on the specimen of Cu thin films whose surface contrast is too low to apply the DIC method. The mechanical properties of Cu thin foils obtained in this study are as follows: elastic modulus E = 89.2 GPa, 0.2% offset yield stress $S_{0.2%}$= 232.8 MPa, tensile strength $S_u$= 319.2 MPa, elongation at fracture ${\varepsilon}_f$=16.8 %, and Poisson's ratio ${\nu}$= 0.34.