• Title/Summary/Keyword: Digestion Method

Search Result 554, Processing Time 0.038 seconds

Optimization of Microwave-Assisted Method for Accelerated Glycated Hemoglobin Quantification from Amino Acids to Proteins

  • Tran, Thi Thanh Huong;Jeong, Ji-Seon
    • Mass Spectrometry Letters
    • /
    • v.8 no.3
    • /
    • pp.53-58
    • /
    • 2017
  • Glycated hemoglobin ($HbA_{1c}$) has been commonly used to screen and diagnose for patients with diabetes mellitus. Here the accelerated procedure of microwave-assisted sample treatment from acid hydrolysis to enzyme digestion followed by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) was optimized and applied to measure $HbA_{1c}$ in an effort to speed up analysis time. First, two signature peptides of $HbA_{1c}$ and hemoglobin $A_0$ were certified with amino acid analysis by setting optimized acid hydrolysis conditions to $150^{\circ}C$, 1.5 h and $10{\mu}M$ sample concentration in 8 M hydrochloric acid. Consequently, the accurate certified peptides above were used as calibration standards to implement the proteolytic procedure with endoproteinase Glu-C at $37^{\circ}C$, 700 W for 6 h. Compared to the traditional method, the microwave heating not only shortened dramatically sample preparation time, but also afforded comparable recovery yields. The optimized protocol and analytical conditions in this study are suitable for a primary reference method of $HbA_{1c}$ quantification with full SI-traceability and other similar proteins in complex biological samples.

Determination of Trace Metals in Atmospheric Particulates by Ion Chromatography

  • Lee Yong-Keun;Kim Hak-Chul;Lee Dong Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1045-1049
    • /
    • 1994
  • A simple and fast ion chromatographic method is developed for the determination of transition metals such as Fe, Cu, Ni, Zn and Co in atmospheric particulates. The method involves acid digestion, on-column preconcentration, and subsequent ion chromatogaphic detection. The precision of the method is less than 3${\%}$ RSD at parts per billion level for the metals studied. No significant interferences are observed. The results obtained with this method agree well with those by ICP-AES.

Pretreatment of Fish for the determination of polycyclic aromatic hydrocarbons using alkali digestion (알칼리분해를 이용한 어류 중 다환방향족탄화수소의 전처리방법)

  • Hu, Soojung;Lee, Hyomin;Chae, Youngzoo;Yoo, Eun-Ah
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.403-409
    • /
    • 2005
  • Polycyclic Aromatic Hydrocarbons(PAHs) contamination arises from several sources including processing of food(smoking, direct drying, cooking) and environmental contamination of air, water, or soil, the later being considered as the most important. In this study, to establish the analytical method for some PAHs[benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, benzo(g,h,i)perylene, indeno(1,2,3-c,d)pyrene] in fish, alkali digestion time, extraction solvents, elution volume of florisil cartridge for clean-up have been optimized. The methodology involved saponification and extraction with n-hexane, clean-up on Sep-Pak florisil cartridges and determination by HPLC/FLD(High Performance Liquid Chromatography/Fluorescence Detector). Overall method recoveries for 8 PAHs spiked into these products ranged from 90 to 106%.

Evaluation of Solidified Fuel Value of Dairy Cattle Manure Digested by Semi-Dry Anaerobic Digestion Method (젖소분뇨 반 건식 혐기소화 잔재물의 고체연료화 가능성 평가)

  • Jeong, Kwang-Hwa;Kim, Jung Kon;Lee, Dong-jun;Cho, Won-Mo;Ravindran, B.;Kwag, Jung-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.4
    • /
    • pp.95-103
    • /
    • 2016
  • The objective of this study was to investigate feasibility of semi-dry anaerobic digestion using dairy cattle manure and to evaluate solidified fuel value of semi-dry anaerobic digestate. To evaluate semi-dry anaerobic digestion using dairy cattle manure, 950 mL bottle type anaerobic reactor was set in the constant temperature room maintained at $35^{\circ}C$. To produce anaerobic digestate for making solidified fuel, acrylic cylindrical anaerobic digester(1,000 mm width ${\times}$ 450 mm height) was set in the constant room temperature to carry out batch test of semi-dry anaerobic digestion using same dairy cattle manure. Moisture content of dairy cattle manure and inoculum solution for anaerobic digestion were 80.64% and 96.83%, respectively. The dairy cattle manure and the inoculum solution was mixed by 1:1 ratio(v/v) for anaerobic digestion. Water content and VS/TS(Volatile Solids/Total Solids) of mixture of substrate and inoculum were 89.74% and 83.35%, respectively. In case of non-inoculated anaerobic digester, the biogas was not produced. By the semi-dry anaerobic digestion, the calorific value of the digestate was reduced by 20% compare to fresh dairy cattle manure. In other hand, ash content increased from 15% to 18.4%. The contents of Cr, Pb, Cd and S of pellet produced from anaerobically digested dairy cattle manure were not against the standard regulation for livestock manure solidified fuel. Therefore, it can be used as fuel that anaerobic digestate produced after semi-dry anaerobic digestion using dairy cattle manure.

A comparative measurement study of Pb, Cd using ICP-AES with different pretreatment methods (ICP-AES를 이용한 전처리방법에 따른 환경시료내 Pb, Cd의 측정 비교 연구)

  • 권태영;윤춘경;전지홍
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.513-520
    • /
    • 1998
  • The evaluation of uncertainty in environmental elemental analysis can be difficult because of the wide variety of analytical sample and objectives. for the specification of measured, elemetal analysis need certain method and high pretreatment technique. The sample of Pb, Cd in paddy soil and sewage sludge were analyzed by same ICP-AES, but each using four different pretreatment technique ; 0.1N HCl extraction, AB-DTPA extraction and two Mixture Acid Digestion. The four technique gave comparable results for the analysis of lead and cadmium. Concentrations determined by Mixture Acid Digestion were more higher than those by 0.1NHCI extraction and AB-DTPA extraction.

  • PDF

Hazardous Substance Analysis of Disposable Diaper for Infant (유아용 일회용 기저귀의 유해성 평가)

  • 신정화;윤혜온;박미애;안윤경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.1
    • /
    • pp.165-171
    • /
    • 2004
  • The analytical method of toxic heavy metals in disposable diapers was developed. Disposable diapers obtained from Korea, Japan, America and German were determinated and quantified. Sample treatment (Total Digestion) was wet chemical acid digestion for extraction of nine hazardous inorganic elements (Sb, As, Pb, Cd, Cr, Co, Cu, Ni, Hg) in disposable diapers. Inductively Coupled Plasma Mass Spectrometer (ICP-MS) and Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES) have been used for analyzing nine hazardous inorganic elements. The results were as follows : The concentration of extractable Sb which was treated for 3 hours with artificial urine and disposable diapers was higher than those of 6 hours and 24 hours. The concentration of extractable Cr was same as Sb. On the other hands, the behavior of Cu and Ni were different from Sb and Cr. Concentrations of extractable Cu and Ni increased as increasing the reaction time between artificial urine and disposable diapers.

Preparation of Traditional Korea Sauce Using Sandfish

  • Myong-No Yi;Jong-Rak Chung
    • Proceedings of the Korean Society for Applied Microbiology Conference
    • /
    • 1976.04a
    • /
    • pp.182.3-182
    • /
    • 1976
  • A laboratory study was made for developing an fermentative method of producing conventional Korean soy sauce type of product from sandfish and defatted soy bean Koji of Aspergillus oryzae as raw material and enzme source, respectively. As an attempt to shorten the fermentation period, the admixture, consisting of pre-chopped sandfish slurry and the Koji of Asp. oryzae (100:15, wet fish weight/dry Koji weight) with added water equal to the fish weight (v/w), was first allowed, while being agitated at 450rpm, to undergo digestion for a 5 hour period at $50^{\circ}C$ with no added salt and then then, after adding 20% salt (w/v), the hydrolysate mixture was ripened for up to 13 weeks at $30^{\circ}C$ and $45^{\circ}C,$ At intervals, an aliquot was withdrawn for determining microbiological, chemical and organoleptic changes taking place in the sandfish-defatted soy bean koji mixture during both digestion and ripening period.

  • PDF

A Micromethod for Rapid and Simple Isolation of Genomic DNA from Small Scale Culture of Bifidobacterium (소량의 Bifidobacterium 배양액에서 genomic DNA 추출을 위한 신속/간단한 방법)

  • Jeakal, Soo;Park, Hee-Kyung;Song, Ji-Eun;Heo, Tae-Ryeon;So, Jae-Seong
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.6
    • /
    • pp.781-783
    • /
    • 1995
  • A method is described for the rapid and simple isolation of genomic DNA from 3 ml culture of Bifidobacterium. The method is expected to be used in gene manipulation of Bifidobacterium spp. The isolated DNA using this method is shown to be an excellent substrate for restriction endonuclease digestion and ligation with T4 DNA ligase.

  • PDF