• 제목/요약/키워드: Diffusion-Weighted Imaging

검색결과 241건 처리시간 0.025초

Transient global amnesia associated with multiple lesions in the corpus callosum and hippocampus

  • Kim, Jin-Ah;Min, Young Gi;Koo, Dae Lim
    • Annals of Clinical Neurophysiology
    • /
    • 제21권2호
    • /
    • pp.102-104
    • /
    • 2019
  • Transient global amnesia is a syndrome of temporary loss of short-term memory and is not accompanied by any other neurological deficit. Diffusion-weighted imaging is useful to improve the diagnostic accuracy of transient global amnesia. We report a 68-year-old woman with multiple lesions on diffusion-weighted imaging in the right corpus callosum and left hippocampus. To the best of our knowledge, this is the first case of a diffusion-weighted imaging lesion in the body portion of the corpus callosum.

Diffusion-Weighted Magnetic Resonance Imaging of the Breast: Standardization of Image Acquisition and Interpretation

  • Su Hyun Lee;Hee Jung Shin;Woo Kyung Moon
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.9-22
    • /
    • 2021
  • Diffusion-weighted (DW) magnetic resonance imaging (MRI) is a rapid, unenhanced imaging technique that measures the motion of water molecules within tissues and provides information regarding the cell density and tissue microstructure. DW MRI has demonstrated the potential to improve the specificity of breast MRI, facilitate the evaluation of tumor response to neoadjuvant chemotherapy and can be employed in unenhanced MRI screening. However, standardization of the acquisition and interpretation of DW MRI is challenging. Recently, the European Society of Breast Radiology issued a consensus statement, which described the acquisition parameters and interpretation of DW MRI. The current article describes the basic principles, standardized acquisition protocols and interpretation guidelines, and the clinical applications of DW MRI in breast imaging.

저자장 자기공명영상시스템에서 선주사확산강조영상기법 개발 (Development of the Line Scan Diffusion Weighted Imaging at Low Tesla Magnetic Resonance Imaging System)

  • 홍철표;이동훈;이도완;이만우;백문영;한봉수
    • 한국방사선학회논문지
    • /
    • 제2권2호
    • /
    • pp.31-38
    • /
    • 2008
  • 0.32 T 자기공명영상시스템에서 선주사영상기법(line scan imaging)을 이용한 확산강조영상(diffusion weighted imaging; DWI) 펄스열(pulse sequence)을 개발하였다. 선주사영상은 단면선택 경사자장과 함께 90도 펄스를 가하여 단면을 선택한 후 y 방향으로 경사자장을 가한 후 180도 라디오파 펄스를 가하여 단면영상의 y-방향 픽셀크기와 같은 너비의 x축에 평행한 띠를 따라 에코가 발생하게 한 뒤 x-방향으로 주파수부호화해서 1차원 k-공간 데이터를 획득하며 이를 1차원 푸리에변환하여 영상을 재구성하였다. 또한 선주사확산강조영상(line scan diffusion weighted image)을 위해서 한 쌍의 사다리꼴모양의 경사자장을 선주사영상기법의 180도 펄스 전후에 대칭으로 배치하였으며 사용된 확산경사자장기울기의 최대값은 G = 15 mT/m 이었고 최대 b 값은 $301.50s/mm^2$이었다. 본 연구에서 개발된 선주사확산강조펄스열을 이용하여 0.32 T 자기공명영상 장비에서 트리아실글리세롤 팬텀(triacylglycerol, TAG) 및 염화나트륨 수용액 (NaCl = 0.1w/v%) 팬텀 영상을 획득하였다. 또한 1.5 T 자기공명영상시스템에서 단일여기에코평면영상화(single shot echo planar imaging)로 동일한 팬텀의 확산강조영상을 구하였다. 선주사확산강조영상은 가장 널리 이용되고 있는 에코평면영상을 이용한 확산강조영상과 비교하여 자화율차이에 의한 영상왜곡이나 화학이동에 의한 허상들이 없음을 확인하였다. 특히 선주사확산강조영상에서 측정한 염화나트륨 수용액 팬텀의 확산계수($963.90{\pm}79.83{\times}10^{-6}mm^2/s$)는 1.5 T에서 계산된 확산계수($956.77{\pm}4.12{\times}10^{-6}mm^2/s$)와 오차범위 내에서 일치하였다.

  • PDF

An Unusual Case of Japanese Encephalitis Involving Unilateral Deep Gray Matter and Temporal Lobe on Diffusion-Weighted MRI

  • Seok, Hee Young;Lee, Dong Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.250-253
    • /
    • 2016
  • Acute Japanese encephalitis (JE) is an endemic viral infectious disease in various parts of Far East and Southeast Asian countries including Korea. Bilateral thalami are the most common involving sites in JE. Other areas including the basal ganglia, substantia nigra, red nucleus, pons, cerebral cortex and cerebellum may be also involved. We report an extremely unusual brain diffusion-weighted MR imaging (DWI) findings in a 53-year-old man with serologically proven JE involving unilateral deep gray matter and temporal lobe, which shows multifocal high signal intensities in left thalamus, left substantia nigra, left caudate nucleus and left medial temporal cortex on T2-weighted image and DWI with iso-intensity on apparent diffusion coefficient (ADC) map.

Preoperative Assessment of Cystic Brain Lesion : Significance of Diffusion-Weighted Image and ADC (Apparent Diffusion Coefficiency) Values

  • Choi, Hyun-Chul;Lee, Sang-Won;Ji, Cheol
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권6호
    • /
    • pp.371-376
    • /
    • 2007
  • Objective : The aim of this study was to investigate the usefulness of diffusion-weighted imaging [DWI] and apparent diffusion coefficiency [ADC] in distinguishing brain abscesses from cystic or necrotic brain tumors, which are difficult to be differentiated by conventional magnetic resonance imaging techniques. Methods : Seven patients with brain abscesses and ten patients with cystic brain tumors were studied from September 2003 to October 2005. Abscess, subdural empyema and ventriculitis were categorized to the abscess group and cystic or necrotic brain gliomas or metastatic brain tumors into the tumor group. Preoperative magnetic resonance images were performed in all patients and diffusion-weighted images and apparent diffusion coefficiency values of lesions were calculated directly from software of 1.5 tesla MRI [General Electrics, USA]. The ratio of the ADC of the lesion to contralateral regional ADC was also measured [relative ADC, rADC]. Results : The average ADC value of pyogenic abscesses group was $0.82+/-0.14{\times}10^{-3}\;[mean+/-S.D.]\;mm^2/s$ and mean rADC was 0.75. Cystic or necrotic areas had high ADC values [$2.49+/-0.79{\times}10^{-3}\;mm^2/s$, mean rADC=2.14]. ADC and rADC values of abscesses group showed about three times lower values than those of cystic or necrotic tumor group. Conclusion : This study results based on numerical comparison of signal intensities and quantitative analysis to distinguish between brain abscess and cystic or necrotic tumor, DWI and ADC mapping are thought to be very useful diagnostic tools.

Diffusion-weighted Imaging and Apparent Diffusion Coefficient Maps for the Evaluation of Pyogenic Ventriculitis

  • Kim, Hyeong-Seok;Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Sung, Jae-Hoon;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권1호
    • /
    • pp.23-27
    • /
    • 2005
  • Objective : The aim of this study is to assess the significance of an apparent diffusion coefficient[ADC] study for diagnosis of ventriculitis. Methods : Seven patients with ventriculitis were enrolled in this study. Diffusion-weighted[DW] magnetic resonance images[MRI] and ADC maps in the dependent intraventricular collection, periventricular white matter and non-dependent cerebrospinal fluid[CSF] were obtained. The images and ADC data from the different lesions were compared. Results : The DW MRI showed marked hyperintensity in the purulent pus lesion, and the corresponding ADC maps revealed prominent hypointensity and restricted ADC values compared with the non-dependent CSF and normal white matter. Conclusion : The decreased ADC value and increased signal intensity of the dependent intraventricular fluid on the DW MRI show restricted water diffusion in the purulent fluid, which is indicative of a pyogenic ventriculitis diagnosis.

확산강조영상의 검사기법에 따른 맥락얼기의 신호강도 분석 (Analysis of Signal Intensity in Choroid Plexuses by Diffusion Weighted Imaging)

  • 오종갑
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.265-269
    • /
    • 2013
  • 뇌척수액을 생산하고 있는 choroid plexuse를 확산강조영상 검사기법에 따라 신호강도를 분석하여 임상적인 유용성을 알아보고자 하였다. $T2^*$-DW-EPI 기법을 적용하여 choroid plexus가 고 신호 강도를 보이는 대상자를 추가적으로 FLAIR-DW-EPI 기법을 적용하여 영상을 얻었다. 두 기법으로 얻은 확산강조영상을 가지고 choroid plexus의 신호강도와 확산계수를 구하여 비교하였다. 그 결과 FLAIR-DW-EPI 기법에서는 choroid plexus의 신호가 뇌 실질과 같거나 저 신호로 나타나 두 기법간의 신호강도의 차이가 있음을 확인하였다. 이는 $T2^*$-DW-EPI 확산강조영상에서 choroid plexus가 고 신호를 보인 환자의 경우 FLAIR-DW-EPI 기법을 추가로 검사하여 정보를 제공함으로서 choroid plexus의 질병 유무를 진단하는데 도움이 될 것으로 생각한다.

관자뼈의 확산강조영상검사 시 Single Shot Turbo Spin Echo 기법의 유용성 (The Utility of Single Shot Turbo Spin Echo Technique for Temporal Bone Diffusion Weighted Imaging)

  • 최관우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권1호
    • /
    • pp.25-30
    • /
    • 2021
  • The purpose was to reduce the distortion of the image that occurs in the temporal bone area due to the very strong differences in susceptibility. A new SS-TSE technique was applied when examining the diffusion-weighted image of the temporal bone, where the auditory and facial nerves to be imaged were very thin and were adjacent to the cranial base including bone and air. This study was conducted from March 2020 to August of the same year, targeting 32 subjects who underwent the diffusion-weighted imaging of the temporal bone. To compare the distortion, existing SS-EPI technique and the new SS-TSE technique were both applied on the temporal bone area. As a result of the study, applying the new SS-TSE technique appeared to lower the distortion of images by 87.44, 46.13 and 42.35 % on the b-value 0, 800 and the ADC images, respectively. In conclusion, when using the new SS-TSE technique on the temporal bone DWI, distortion can be reduced, and thus images with high diagnostic value can be obtained.

Recurrence and Metastasis of Lung Cancer Demonstrate Decreased Diffusion on Diffusion-Weighted Magnetic Resonance Imaging

  • Usuda, Katsuo;Sagawa, Motoyasu;Motomo, Nozomu;Ueno, Masakatsu;Tanaka, Makoto;Machida, Yuichiro;Maeda, Sumiko;Matoba, Munetaka;Tonami, Hisao;Ueda, Yoshimichi;Sakuma, Tsutomu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권16호
    • /
    • pp.6843-6848
    • /
    • 2014
  • Background: Diffusion-weighted magnetic resonance imaging (DWI) is reported to be useful for detecting malignant lesions. The purpose of this study is to clarify characteristics of imaging, detection rate and sensitivity of DWI for recurrence or metastasis of lung cancer. Methods: A total of 36 lung cancer patients with recurrence or metastasis were enrolled in this study. While 16 patients underwent magnetic resonance imaging (MRI), computed tomography (CT) and positron emission tomography-computed tomography (PET-CT), 17 underwent MRI and CT, and 3 underwent MRI and PET-CT. Results: Each recurrence or metastasis showed decreased diffusion, which was easily recognized in DWI. The detection rate for recurrence or metastasis was 100% (36/36) in DWI, 89% (17/19) in PET-CT and 82% (27/33) in CT. Detection rate of DWI was significantly higher than that of CT (p=0.0244) but not significantly higher than that of PET-CT (p=0.22). When the optimal cutoff value of the apparent diffusion coefficient value was set as $1.70{\times}10^{-3}mm^2/sec$, the sensitivity of DWI for diagnosing recurrence or metastasis of lung cancer was 95.6%. Conclusions: DWI is useful for detection of recurrence and metastasis of lung cancer.

Hyperperfusion in DWI Abnormality in a Patient with Acute Symptomatic Hypoglycemic Encephalopathy

  • Park, Ji Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.106-108
    • /
    • 2017
  • The perfusion change in acute symptomatic hypoglycemic encephalopathy (ASHE) is not well known. We present the perfusion-weighted imaging of a patient with ASHE. The area of diffusion-weighted imaging abnormalities and adjacent normal-appearing white matter showed increased cerebral blood volume and flow, and shortening of time-to-peak.